Check SEL to, Mem mirror OFF
View all Dell External OEMR R410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC The system BIOS has Remove AC power to the disabled memory system for 10 seconds and mirroring because it has restart the system. determined one half of the If the problem persists, mirror has had too many see "Troubleshooting errors. "## & ##" System Memory" on represents the page 152. memory-module pair implicated by the BIOS. I1910 Intrusion detected. Check chassis cover. System cover has been removed. Information only. I1911 LCD Log Full. Check SEL to review all Errors. LCD overflow message. Check the SEL for details A maximum of ten error on the events. messages can display Remove AC power to the sequentially on the LCD. system for 10 seconds or The eleventh message clear the SEL. instructs the user to check the SEL for details on the events. I1912 SEL full. The SEL is full of events Check the SEL for details Review & clear and is unable to log any on the events, then clear log. more. the SEL. I1920 iDRAC6 Upgrade optional iDRAC6 has Successful been upgraded successfully. Information only. W1228 RAID Controller battery capacity < 24hr. Warns predictively that the RAID battery has less than 24 hours of charge left. Allow RAID battery to charge to greater than 24 hours of sustained charge. If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 118." About Your System 35