Dell PowerConnect OpenManage Network Manager Release Notes 5.2 - Page 9

Supported Powerconnect B-Series Devices

Page 9 highlights

9 are in the CLI. Workaround: Rebooting switch sets the Last Update back to zero. Once done, the LLDP Stats works again. (8213) • Cable Tests on ports in a stack may fail, producing the message Test has not been preformed. Workaround: Make sure the management (master) switch is set to Unit-1 in the stack. (8129) • Stacked switches change IP addresses when the master is moved. Moving master does not function properly in stack configuration. (7002) • When editing any interface set to disabled mode, and choosing vlan tagging from the combo box, you will not be able to add a VLAN ID. The field is grayed out. Workaround: Switch the selection to another item and then back to the desired one. (6355) • You must use the command-line interface to deploy new firmware for the 5324 model (4739) • LLDP modification through this application may not work on M8024 devices, therefore you must setup LLDP through the telnet CLI. (2583) • Banners are supported only up to 256 characters in length. (2265) • You must wait more than three minutes to deploy another firmware version after you successfully deploy the first firmware version. Deploying firmware can also fail with the default timeout value. You can increase the timeout value from the Management interface and also in \owareapps\dellpoewrconnet\dellpc.properties. (6680) Supported Powerconnect B-Series Devices Supported models include: M8428k. Support is included for firmware versions 5.2.0 or higher. Known Issues • M8428K does not display the correct model number, performance indicators and serial number in the details panel. (17447) • A limited amount of interface data is collected from Powerconnect B-Series Ethernet capable switches. As a result, interface reports and the Interfaces portlet do not contain Ethernet Link data for these devices. This also means Ethernet Links do not appear for these devices.(18800, 18802) • Right-click menu in Performance - Top Ping Response portlet does not appear. Workaround: Right-click in the Managed Resources portlet. (18827) • Network Details VLAN screen for B-RX devices does not display VLAN information since required MIBs are not supported or populated by the device. (16419) • Informs are not supported on these devices. If you check the checkbox to send informs to v3 trap recipients it will send informs rather that v3 traps. Workaround: Don't check the checkbox. (18435) • Deploying firmware to these devices requires an external file server. (12512) • OMNM will not telnet connect to some devices if they use the factory default password. You must set the password to something other than that default DOESNOTRECOGNIZETHEADDITIONALPROMPTASKINGTHATDEFAULTPASS WORDBECHANGEDEACHTIMELOGINOCCURS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

9
are in the CLI.
Workaround:
Rebooting switch sets the Last Update back to
zero. Once done, the LLDP Stats works again. (8213)
• Cable Tests on ports in a stack may fail, producing the message
Test has not
been preformed
.
Workaround:
Make sure the management (master) switch
is set to Unit-1 in the stack. (8129)
• Stacked switches change IP addresses when the master is moved. Moving
master does not function properly in stack configuration. (7002)
• When editing any interface set to disabled mode, and choosing vlan tagging
from the combo box, you will not be able to add a VLAN ID. The field is
grayed out.
Workaround:
Switch the selection to another item and then back
to the desired one. (6355)
• You must use the command-line interface to deploy new firmware for the
5324 model (4739)
• LLDP modification through this application may not work on M8024
devices, therefore you must setup LLDP through the telnet CLI. (2583)
• Banners are supported only up to 256 characters in length. (2265)
• You must wait more than three minutes to deploy another firmware version
after you successfully deploy the first firmware version. Deploying firmware
can also fail with the default timeout value. You can increase the timeout
value from the Management interface and also in
\owareapps\dellpoewr-
connet\dellpc.properties
. (6680)
Supported Powerconnect B-Series Devices
Supported models include:
M8428k.
Support is included for firmware versions 5.2.0 or higher.
Known Issues
• M8428K does not display the correct model number, performance indicators
and serial number in the details panel. (17447)
• A limited amount of interface data is collected from Powerconnect B-Series
Ethernet capable switches. As a result, interface reports and the Interfaces
portlet do not contain Ethernet Link data for these devices. This also means
Ethernet Links do not appear for these devices.(18800, 18802)
• Right-click menu in Performance - Top Ping Response portlet does not appear.
Workaround:
Right-click in the Managed Resources portlet. (18827)
• Network Details VLAN screen for B-RX devices does not display VLAN infor-
mation since required MIBs are not supported or populated by the device.
(16419)
• Informs are not supported on these devices. If you check the checkbox to
send informs to v3 trap recipients it will send informs rather that v3 traps.
Workaround:
Don’t check the checkbox. (18435)
• Deploying firmware to these devices requires an external file server. (12512)
• OMNM will not telnet connect to some devices if they use the factory default
password.
You must set the password to something other than that default.