Dell PowerEdge 400SC Service Manual (.htm) - Page 8
Close the system cover, Rotate the processor cooling shroud down. See
View all Dell PowerEdge 400SC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
www.dell.com | support.dell.com 14 Place one end of the heat sink under the retention module tab on the side opposite the removed clip, and lower the heat sink onto the processor until the heat sink snaps securely in the retention module. See Figure 1-3. 15 Replace the retention module clip by pressing in on the tab and lowering that end of the clip into the retention module. See Figure 1-3. 16 Rotate the processor cooling shroud down. See Figure 1-2. 17 Close the system cover: a Pivot the cover down and into position. See Figure 1-1. b Press down on the cover to close it. 18 If you are using a padlock to secure your system, install the padlock. 19 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 1-6 Processor Upgrade Installation Guide