Dell PowerEdge C6145 User Manual - Page 15

Temperature, Relative humidity, Maximum vibration, Maximum shock

Page 15 highlights

Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550 ft. Storage Relative humidity Operating Storage Maximum vibration Operating Storage Maximum shock Operating Storage -40° to 65°C (-40° to 149°F) with a maximum temperature gradation of 20°C per hour 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour 5% to 95% (noncondensing) 0.26 Grms at 5-350 Hz 1.88 Grms at 10-500 Hz for 15 min One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms; Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second) Getting Started With Your System | 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Getting Started With Your System
|
15
Environmental
NOTE:
For additional information about environmental measurements for specific system
configurations, see
www.dell.com/environmental_datasheets
.
Temperature
Operating
10° to 35°C (50° to 95°F) with a
maximum temperature gradation of
10°C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1°F/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation of
20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with a
maximum humidity gradation of 10%
per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 Grms at 5–350 Hz
Storage
1.88 Grms at 10–500 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis
(one pulse on each side of the system)
of 31 G for 2.6 ms in the operational
orientation
Storage
Six consecutively executed shock
pulses in the positive and negative x, y,
and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms;
Six consecutively executed shock
pulses in the positive and negative x, y,
and z axes (one pulse on each side of
the system) of 22 G faired square wave
pulse with velocity change at 200
inches/second (508 centimeters/second)