Temperature, Relative humidity, Maximum vibration, Maximum shock
View all Dell PowerEdge C6145 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550 ft. Storage Relative humidity Operating Storage Maximum vibration Operating Storage Maximum shock Operating Storage -40° to 65°C (-40° to 149°F) with a maximum temperature gradation of 20°C per hour 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour 5% to 95% (noncondensing) 0.26 Grms at 5-350 Hz 1.88 Grms at 10-500 Hz for 15 min One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms; Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second) Getting Started With Your System | 15