Dell PowerEdge M420 Dell Converged Enhanced Ethernet Command Reference
Dell PowerEdge M420 Manual
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerEdge M420 manual content summary:
- Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 1
53-1002115-01 07 December 2010 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 2
the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, and Dell OpenManage are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, Windows Server, MS - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 3
xiii How this document is organized xiii Supported hardware and software xiv Document conventions xiv Text formatting xiv Command syntax conventions xv Notes, cautions, and warnings xv Notice to the reader xv Getting technical help xvi Contacting Dell xvi Chapter 1 CLI Basics In this - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 4
show media 31 show media interface 32 show media linecard 33 show processes cpu 34 show processes memory 35 show protect-mode status 36 show running-config 37 show startup-config 38 show system 39 show tech-support 40 show users 41 show version 42 terminal length 43 terminal monitor 44 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 5
66 show ip interface 68 shutdown 70 speed 71 track 72 track interface 73 IP Configuration Commands arp 75 arp-ageing-timeout 76 clear arp-cache 77 clear ip fib 78 proxy-arp 85 ip route 86 ip trap-to-cpu 87 show arp 88 show interfaces 89 show ip fib 90 show ip forwarding 91 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 6
lldp 114 show lldp interface 115 show lldp neighbors 116 show lldp statistics 118 system-description LINE 119 system-name 120 Link Aggregation Control Protocol Commands channel-group 121 clear lacp 123 clear lacp counters 124 debug lacp 125 lacp system-priority 127 lacp timeout 128 vi - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 7
channel 132 Layer 2 System Commands mac-address-table 133 show mac-address-table 135 FCoE Configuration Commands fcoe-map 137 fcoeport 138 fcoe-vlan 139 show fcoe-map 140 Layer 2 ACL interval 163 forward-delay 164 Dell Converged Enhanced Ethernet Command Reference vii 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 8
group 199 clear ip igmp groups 201 debug ip igmp all 202 ip igmp last-member-query-interval 203 ip igmp query-interval 204 viii Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 9
monitor 229 RMON Commands rmon alarm 231 rmon collection history 233 rmon collection stats 234 rmon event 235 show rmon 236 show rmon history 238 Dell Converged Enhanced Ethernet Command Reference ix 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 10
interface 268 dot1x authentication 269 dot1x enable 270 dot1x port-control 271 dot1x quiet-period 272 dot1x reauthenticate interface 273 authperiod 276 dot1x timeout server-timeout 277 dot1x timeout supp-timeout 278 dot1x timeout tx-period 279 x Dell Converged Enhanced Ethernet Command - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 11
show dot1x 280 show dot1x all 281 show dot1x diagnostics interface 283 show dot1x interface 284 show dot1x session-info interface 285 show dot1x statistics interface 286 Dell Converged Enhanced Ethernet Command Reference xi 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 12
xii Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 13
is organized xiii •Supported hardware and software xiv •Document conventions xiv •Notice to the reader xv •Getting technical help xvi How this Protocol Commands" describes the commands used to configure and maintain IGMP snooping. Dell Converged Enhanced Ethernet Command Reference xiii 53 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 14
port authentication configuration commands. Supported hardware and software The following hardware platform is supported in this release: • Dell M8428-k Within this manual, any appearance of the term "Dell FCoE hardware" is referring to: • Dell M8428-k • Dell FCOE10-24 port blade • Dell Converged - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 15
passwords, appear in angle brackets Default responses to system prompts appear in notices and statements are used in this manual. They are listed below in order of to you or cause damage to hardware, firmware, software, or data. DANGER Dell Converged Enhanced Ethernet Command Reference xv 53- - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 16
your investment in our products remains cost-effective. If you need assistance, or find errors in the manuals, contact Dell Technical Support. Contacting Dell For customers in the United States, call 800-WWW.DELL (800.999.3355). NOTE If you do not have an active Internet connection, you can find - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 17
supporting FCoE and CEE. telnet 10.32.152.21 switch login: userid Password:xxxxxx switch cmsh - cmsh takes you to the CEE Dell M8428-k CLI prompt. switch> CLI command modes Following are the main command modes for the Dell FCoE hardware: • EXEC • Privileged EXEC • Global configuration • Interface - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 18
a Telnet session. From the global configuration mode, specify a feature by entering one of the following feature names: • cee-map • fcoe-map • mac access-list • monitor session Access and configure CEE, FCoE, Port Mirroring, and ACL features. 2 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 19
Lists block traffic based on any given packet attribute. Use Extended access control lists to test source and destination addresses and other IP packet data, such as protocols, TCP or UDP port numbers, type of service and to provide Reflective access-lists and Time-based access-lists.capabilities - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 20
1 Internal and external 10 Gbps Ethernet interfaces syntax 4 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 21
server/path] SCP Copies to URL scp:// [username [:password]@server/path] running-config Copies to the current running configuration. startup--config Copies to the current startup configuration file. Defaults running-config Dell Converged Enhanced Ethernet Command Reference 5 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 22
://]filename FTP Copies to URL ftp:// [username [:password]@server/path] SCP Copies to URL scp:// [username [:password]@server/path] running-config Copies to the current running configuration. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 23
the local switch using the following format: [flash://]filename. Defaults There is no default configuration for this command. Command Privileged EXEC mode Modes Description Use Continue?(y/n):y See Also copy startup-config Dell Converged Enhanced Ethernet Command Reference 7 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 24
contents of the current directory. Synopsis dir Operands none Defaults The default is the current directory. Command Privileged EXEC mode Modes Description rmon_config rmon_configuration starup-config See Also delete 8 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 25
to the EXEC mode. Synopsis disable Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Using the exit or quit commands from the Privileged EXEC mode ends the session instead of returning to the EXEC mode. Examples To return to the - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 26
the configuration mode. do command command Specifies the command you want to run. Defaults There are no default configurations for this command. Command All configuration modes rmon_configuration starup-config See Also none 10 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 27
Privilege EXEC mode. Synopsis enable Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes EXEC mode ends the session. Examples To enable the Privileged EXEC mode: switch> enable switch# See Also disable Dell Converged Enhanced Ethernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 28
all configuration modes. Synopsis end Operands none Defaults There are no default configurations for this command. Command All configuration modes configuration mode: switch(config)#interface intengigabitethernet 0/0 switch(conf-if-te-0/0)#end switch# See Also exit, disable, enable 12 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 29
the Flash. Synopsis erase flash Operands none Defaults There are no default configurations for this command. Command Configuration mode Modes Description Use this command to erase erase?(y/n):y switch# See Also dir, delete Dell Converged Enhanced Ethernet Command Reference 13 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 30
The range is 0-2147483. Defaults The default is 10 minutes. Command Console and VTY (line) configuration mode Modes Description Use this 0 (zero) causes the Telnet session to wait indefinitely. Examples To configure the wait interval for the console session: switch(config)#line console 0 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 31
. Synopsis exit Operands none Defaults There are no default configurations for this command. Command configuration mode, and return to the Configuration mode: switch(config)#interface intengigabitethernet 0/0 switch(conf-if-te-0/0)#exit switch(config)#exit See Also end, enable, disable Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 32
cmsh shell. fos command command Specifies the Fabric OS command. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use portstatsshow slotpoweroff slotpoweron slotshow 16 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 33
applies to the listed commands. The fcoelogincfg, fcoelogingroup, and fcoelogincfg commands are not supported from cmsh shell. See the Fabric OS Command Reference for additional information on :00:05:1e:76:42:00 See Also none Dell Converged Enhanced Ethernet Command Reference 17 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 34
Defaults There are no default configurations for this command. Command Global configuration mode Modes Description Use this command to configure the Line configuration mode, which allows you to configure To configure the wait interval for the console session: switch>enable switch#configure terminal - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 35
. Defaults There are no default configurations for this command. Command Global configuration mode Modes Description Use this command to configure the user: switch#configure terminal switch(config)#line vty 23 31 switch(conf-line)#exec-timeout 2 30 See Also show line Dell Converged Enhanced - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 36
-mode enable Operands none Description In the Blade Center Chassis environment, the Management Module (AMM) controls the operation of the switch by configuring and initializing it. Protect mode of operation is a special mode which needs to be supported by both the switch and the AMM. Protect - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 37
default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to view the current working directory. Usage There are no usage guidelines for this command. Guidelines Examples To view the current working directory: switch#pwd flash: See Also none Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 38
file name to change. Specifies the new name of the file. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command Feb 4 13:16:00 2009 file2 See Also none 22 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 39
script file in the Flash memory. Description Use this command to run a script file residing in the Flash. Defaults There are no default configurations for this command. Command Privileged EXEC Mode Modes User Guidelines The scripting support only supports textual configuration files. It does not - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 40
no default configurations for this command. Command Privileged EXEC Mode Modes User Guidelines There are no usage guidelines for this command. Example switch#show accounting logs 2009/06/24-03:33:45 (UTC), root/root/10.2.2.47/telnet/CLI/Frisco-34, config; rmon event 15 See Also none 24 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 41
hardware clock. Synopsis show calendar Operands none Defaults There are no default configurations hardware clock. Usage There are no usage guidelines for this command. Guidelines Examples To display calendar information: switch#show calendar 16:33:30 UTC Tue Feb 14 2009 See Also none Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 42
time and date from the system clock. Synopsis show clock Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this 18 2009 See Also show calendar 26 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 43
power system (RPS) availability, and power information for the switch. Synopsis show environment Operands none Defaults There are no default configurations Status -Fan 1 is Ok Fan 2 is Ok Fan 3 is Ok -- Power Supplies -PS0 is OK PS1 is faulty -- Unit Environment Status -- Sensor State - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 44
file_name Specifies the file whose contents are to be displayed. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this mstp instance 1 vlan 100 ! See Also dir 28 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 45
0-31. Specifies the last line number. The range of valid values is 0-31. Defaults If the line is not specified, it displays all VTY and console information. Command Privileged 24 24 See Also line vty, line console, exec-timeout Dell Converged Enhanced Ethernet Command Reference 29 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 46
syslog buffer of the switch. Synopsis show logging Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Port-channel 10 is link down See Also none 30 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 47
present on a switch. Synopsis show media Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes TX Power 0.1 (uWatts) RX Power 0.1 (uWatts) (output truncated) See Also show media interface, show media linecard Dell Converged - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 48
for a specific interface. show media interface {{in | ex}tengigabitethernet slot/port} Operands extengigabitethernet Specifies a valid external 10 Gbps Ethernet interface. slot Specifies a valid slot number. port Specifies a valid port number. Defaults There are no default configurations for - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 49
interfaces of a specific line card. show media linecard number number Linecard number. Defaults There are no default configurations for this command mAmps) TX Power 0.1 (uWatts) RX Power 0.1 (uWatts) (output truncated) See Also show media interface, show media Dell Converged Enhanced - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 50
CPU utilization statistics. Synopsis show processes cpu [summary] Operands summary Shows a summary of CPU usage by all processes. Defaults There are no default configurations for 0.00 S 14:18:35 Feb 19, 2009 See Also none 34 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 51
memory [summary] Operands summary Shows a summary of memory usage by all processes. Defaults There are no default configurations - 3 events/0 0.00 0 - - 4 khelper 0.00 0 - - 5 kthread 0.00 0 - - See Also none Dell Converged Enhanced Ethernet Command Reference 35 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 52
protect-mode status Operands none Description Use this command to display the current status of protect mode. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 53
configuration. Displays the interface configuration. Displays the LLDP configuration. Displays the Remote Monitoring Protocol (RMON) configuration. Displays the switch configuration. Defaults There are no default configurations See Also show startup-config Dell Converged Enhanced Ethernet Command - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 54
the content of the startup configuration file. Synopsis show startup-config Operands none Defaults There are no default configurations for this command. Command InTenGigabitEthernet 0/3 shutdown See Also write memory, write erase 38 Dell Converged Enhanced Ethernet Command Reference 53- - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 55
Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to display system information of hardware 0 -Unit Name Status Hardware Rev FC Port(s) Tengig 00 : 10.35.155.204 : UP -- Power Supplies -PS0 is OK PS1 is OK -- Fan - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 56
tech-support Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to run a script that automatically runs a variety of show commands with output that is useful to Technical Support for troubleshooting. Usage - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 57
currently logged into the switch. Synopsis show users Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use all users logged in. See Also show line Dell Converged Enhanced Ethernet Command Reference 41 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 58
Build Time: 03:35:17 Feb 18, 2009 E209 uptime: 04:14:43 Firmware name: v6.1.2 Switch Model Name: Dell M8428-k Control Processor: Freescale Semiconductor 8548E with 1016 MB of memory 4MB of boot flash memory. 8 FC Port(s) 24 Ten GigabitEthernet/IEEE 802.3 interface(s) switch# See Also show system - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 59
number of lines to display on a screen. The range of valid values is 0-512. Defaults The default length is 24. Command Privileged EXEC mode Modes Description Use this command to set the switch#terminal length 30 See Also none Dell Converged Enhanced Ethernet Command Reference 43 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 60
outputs on a terminal. Synopsis terminal monitor terminal no monitor Operands none Defaults The terminal monitor option is disabled. Command Privileged EXEC mode Modes terminal: switch#terminal no monitor See Also none 44 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 61
Description Use this command to remove a startup configuration. Usage There are no usage guidelines for this command. Guidelines Examples To clear a startup configuration: switch#write erase See Also write memory write erase 2 Dell Converged Enhanced Ethernet Command Reference 45 53-1002115 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 62
Copies the current running configuration to the startup configuration file. Synopsis write memory Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to copy the current running configuration to the startup - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 63
VLAN as the incoming VLAN-tagged packets. By configuring a converged interface to classify untagged packets (by using classifiers or the default port vlan_id) to the same VLAN as VLAN-tagged packets coming into the interface, the FCoE hardware sends out untagged packets to the CNA. These packets - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 64
configuration . Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to show the running system status and configuration mode Ingress filter Acceptable frame types Default Vlan Active Vlans Inactive Vlans : - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 65
Operands Displays information about a specific VLAN interface. show vlan { FCoe VLAN interfaces. Defaults There are no default configurations for this command. VLAN Name State Ports (u)-Untagged, (t)-Tagged (c)-Converged 1 default ACTIVE Te 0/0(t) Te 0/4(t) Te 0/5(t) Te 0/8(t) Te - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 66
to display. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display information about all configured VLAN classifier groups or a specific VLAN interface group. Usage If a group ID is not - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 67
of the Layer 2 mode. Usage For changing the interface configuration mode to trunk or changing the default VLAN mapping, use Guidelines additional switchport commands. Examples To put mode, switchport access, switchport trunk Dell Converged Enhanced Ethernet Command Reference 51 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 68
port VLAN (PVID) to the specified vlan_id. The range of valid values is 1-3583. Defaults By default, all Layer 2 interfaces are in access mode and belong to the VLAN ID 1. Command Interface configuration mode Modes Description Use this command to set the Layer 2 interface as access. In access - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 69
The range of valid values is 2-3583. Defaults The default native VLAN for a converged interface is 1. Command Interface configuration mode Modes Description Use this command to add switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 70
trunk. Sets the layer 2 interface as converged. Defaults There are no defaults for this command. Command Interface configuration mode Modes Description Use this command to set the mode interface switchport, switchport trunk 54 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 71
The range of valid values is 2-3583. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command to add switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 55 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 72
The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command to activate activate group 1 vlan 5 See Also none 56 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 73
VLAN as the incoming VLAN-tagged packets. By configuring a converged interface to classify untagged packets (by using classifiers or the default port vlan_id) to the same VLAN as VLAN-tagged packets coming into the interface, the FCoE hardware sends out untagged packets to the CNA. These packets - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 74
the Media Access Control (MAC) list. mac_address Specifies the MAC address-based VLAN classifier rule used to map to a specific VLAN. vlan - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 75
See Also show vlan interface vlan classifier rule 3 Dell Converged Enhanced Ethernet Command Reference 59 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 76
3 vlan classifier rule 60 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 77
There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines The clear counters all command does not clear counters for any of the protocol daemon stats like LLDP, LACP, MSTP, and so on. For the Dell M8428-k switch, the slot number is always 0 (zero - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 78
4 clear counters See Also show interfaces 62 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 79
number of characters is 64. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command conf-if-te-0/1)#description converged_101 See Also none Dell Converged Enhanced Ethernet Command Reference 63 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 80
number. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command Global configuration mode Modes Description Use this command to create or enter the interface configuration mode to configure an interface. Usage There are no usage guidelines for - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 81
Gbps Ethernet interfaces use a default MTU of 2500 bytes. Command Interface configuration mode Modes Description Use this command to specify the MTU on the interface. Usage Creating MTUs under VLAN interfaces is not valid. Guidelines Examples none See Also none Dell Converged Enhanced Ethernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 82
Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the detailed interface configuration and capabilities of all interfaces or for a specific Overruns: 0 66 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 83
filter Acceptable frame types Default Vlan Active Vlans Inactive mode Ingress filter Acceptable frame types Default Vlan Active Vlans Inactive Vlans : ExTenGigabitEthernet Switchport mode Ingress filter Acceptable frame types Default Vlan Active Vlans Inactive Vlans : ExTenGigabitEthernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 84
display a the VLAN number. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display up down up up down up up down down 68 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 85
administratively down administratively down down up up up down down up up down up down up down up up up up up down down down Dell Converged Enhanced Ethernet Command Reference 69 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 86
interface. Synopsis shutdown no shutdown Operands none Defaults The interface is disabled. Command Interface configuration mode Modes Description Use this command to disable Also interface, show ip interface, show interface 70 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 87
the speed negotiation value for the interface. Defaults The default setting for this command is auto. Command Interface configuration mode. Modes User Guidelines The speed command conf-if-int-0/1)#speed 10000 See Also none Dell Converged Enhanced Ethernet Command Reference 71 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 88
. Synopsis track enable no track enable Operands none Description Use this command to enable tracking. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use the no track version to disable this command. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 89
range of valid values is 1-63. Description Use this command to enable tracking on an interface. Defaults There are no default configurations for this command. Command Interface configuration mode Modes User Guidelines Use the no track interface version to disable this command. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 90
4 track interface 74 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 91
Synopsis Operands Configures a static ARP connection. arp ip-address hardware-address no arp ip-address ip-address hardware-address no arp a local data link address. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 92
ageing-timeout minutes Number of minutes until the timeout occurs. Description Use this command to configure the ARP timeout. Defaults Default value is 240 minutes (four hours.) Command Global configuration mode Modes User Guidelines Use no arp-ageing-timeout to disable this function. Example - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 93
the ARP. no-refresh Do not refresh the ARP. Description Use this command to clear the ARP statistics cache on the host. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 94
fib {slot slot-number} slot slot-number Clears the FIB and hardware for the blade slot number. The only valid value is 0. Description Use this command to clear the FIB and hardware. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 95
to clear statistics on all interfaces. Description Use this command to clear all or some of the IP routes on the switch. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 96
the IP traffic statistics. Synopsis clear ip traffic Operands none Description Use this command to clear the IP traffic statistics. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 97
. Counts only received packets. Description Use this command to display the ARP traffic, for all interfaces or a specific interface. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 98
to display all IGMP or ICMP packets received or transmitted. Can be enabled globally, per interface, or on a multicast group. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 99
are supported. Dotted-decimal is not supported. Specifies that the configured address is a secondary IP address. If this keyword is omitted, the configured address is the primary IP address. Description Use this command to configure an IP address. Defaults There are no default configurations for - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 100
Command VLAN interface configuration mode Modes User Guidelines Use the command no ip mtu to disable the MTU. The valid range is from 576 through 9018. The default IP MTU size is 1500 bytes. The default link MTU size is 2500 bytes. Example none See Also none 84 Dell Converged Enhanced Ethernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 101
Enables proxy ARP on the switch. Synopsis ip proxy-arp no ip proxy-arp Operands none Description Use this command to enable proxy ARP. Defaults By default, proxy ARP is disabled. Command Privileged EXEC mode Modes User Guidelines Use no ip proxy-arp to disable proxy ARP. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 102
route ip route Synopsis Operands Configures a static IP route. . Both dotted decimal and integers between 1-32 are supported. IP address of the next hop that can be to configure static IP routes. Defaults There are no default configurations for this command. Command Global configuration mode - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 103
IP fragmentations or TTL violations to the CPU. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use no ip trap-to-cpu to disable the trap. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 87 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 104
interface-number Layer-2 or layer-3 Interface number. Description Use this command to display the contents of the ARP cache. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 105
, null, port-channel, or VLAN). Layer-2 or layer-3 Interface number. Description Use this command to display interface information. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 106
the FIB and hardware for the blade slot number. The only valid value is 0. number chip-number Displays the FIB and hardware for the chip slot number. The valid values are 0-2. Description Use this command to display the FIB information. Defaults There are no default configurations for this - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 107
There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip interface, show ip fib, show interfaces show ip forwarding 5 Dell Converged Enhanced Ethernet Command Reference 91 53 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 108
or VLAN). interface-number Layer-2 or layer-3 Interface number. Description Use this command to display IP interface information. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 109
IP routing information. Defaults There are no default configurations for this command ia - IS-IS inter area, * - candidate default, U - per-user static route o - ODR, P - periodic downloaded static route Gateway of last resort is 10.32 Dell Converged Enhanced Ethernet Command Reference 93 53-1002115- - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 110
brief summary of the current IP routing table. Defaults There are no default configurations for this command. Command EXEC mode Modes User 2 Overhead 64 128 192 See Also show ip route Memory (bytes) 160 320 1180 1660 94 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 111
dcbx-fcoe-app-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to FCoE priority, and Priority Flow Control (PFC) pause. Use the no advertise dcbx-fcoe-app-tlv command to return to the default setting. Usage There are - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 112
-link-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dcbx-fcoe-app-tlv, advertise dcbx fcoe-app-tlv 96 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 113
dcbx-tlv Operands none Defaults Advertise is enabled. Command Protocol LLDP configuration mode Modes Description default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dot1-tlv, advertise dot3-tlv, advertise optional-tlv Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 114
-tlv Advertises to any attached device IEEE 802.1 organizationally specific Type, Length, Value (TLV). Synopsis advertise dot1-tlv no advertise dot1-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise to - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 115
-tlv Advertises to any attached device IEEE 802.3 organizationally specific Type, Length, Value (TLV). Synopsis advertise dot3-tlv no advertise dot3-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise to - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 116
of the system. system-description Describes the system firmware version and the current image running on the system. system-name Specifies the name of the system. Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to display the - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 117
a valid slot number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use clear lldp neighbors See Also show lldp neighbors Dell Converged Enhanced Ethernet Command Reference 101 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 118
a valid slot number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this lldp statistics See Also show lldp statistics 102 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 119
LLDP packets. tx Turns on debugging for only transmitted LLDP packets. Defaults By default, debugging is not turned on. Command Privileged EXEC mode Modes Description te0/1 : Transmit Receive See Also show debug lldp Dell Converged Enhanced Ethernet Command Reference 103 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 120
describing the LLDP protocol. Defaults There are no default configurations for this command. Command Protocol LLDP configuration mode Modes Description Use this LLDP: switch(conf-lldp)#description Dell-LLDP See Also none 104 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 121
of valid values is 4-180 seconds. Defaults The default is 30 seconds. Command Protocol LLDP configuration mode Modes Description Use this command to transmissions: switch#configure terminal switch (config) #protocol lldp switch(conf-lldp)#hello 10 See Also none Dell Converged Enhanced Ethernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 122
) DCBX version. Specifies to use the standard DCBX version, which is the version released prior to the CEE DCBX release. Defaults The default is auto. Command Interface configuration mode Modes Description Use this command to specify which version of the DCBX protocol to use. Usage There are no - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 123
disable no lldp disable Operands none Defaults By default, LLDP is enabled at both the global and interface levels. Command Interface configuration mode Modes Description Use this command -te-0/1)#lldp disable See Also none Dell Converged Enhanced Ethernet Command Reference 107 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 124
-bits value no lldp fcoe-priority-bits value Specifies the bitmap value. The range of valid values is 0 to 15. Defaults The default value is 8. Command Interface configuration mode Modes Description Use this command to set the priorities on which FCoE traffic will be allowed. The no lldp fcoe - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 125
profile name. Defaults If the parameters are not defined in the profile, the default values are used. Command Interface configuration mode Modes this command is not present, the parameters defined in the global LLDP configuration are used. Examples To apply an LLDP profile on an interface: switch - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 126
receive mode. Defaults Both transmit and receive modes are enabled. Command Protocol LLDP configuration mode Modes default setting. Usage There are no usage guidelines for this command. Guidelines Examples To enable only the transmit mode: switch(conf-lldp)#mode tx See Also show lldp 110 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 127
1-10. Defaults The default multiplier value is 4. Command Protocol LLDP configuration mode Modes Description default setting. Usage There are no usage guidelines for this command. Guidelines Examples To set the number of consecutive misses: switch(conf-lldp)#multiplier 2 See Also hello Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 128
profile. profile name no profile name name Assigns a name to the profile. The valid value is a maximum of 32 characters. Defaults none Command Protocol LLDP configuration mode Modes Description Use this command to create an LLDP profile. Usage Guidelines When you apply an LLDP profile on an - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 129
. Use the no protocol lldp command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To clear all LLDP configurations: switch(config)#no protocol lldp See Also none Dell Converged Enhanced Ethernet Command Reference 113 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 130
status on the switch. Synopsis show debug lldp Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command Transmit Receive Detail See Also none 114 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 131
number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command EXEC mode Modes Timer: 1 seconds DCBX Version : CEE Auto-Sense : Yes Transmit TLVs: Chassis ID Port ID TTL IEEE DCBX DCBX FCoE App DCBX FCoE Logical Link Link - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 132
for the specified interface. Defaults There are no default configurations for this command. Command LLDP neighbor information on a specific interface: switch#show lldp neighbors (IF Name) Dead Interval: 120 secs Remaining Life : 100 secs Tx: 536 Rx: 535 Chassis ID: 0005.1e76.1020 (MAC) Remote Mac - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 133
Spanning Tree Protocol Remote VLANs Configured: VLAN ID: 1 VLAN Name: default AutoNego Support: Supported Not Enabled AutoNego Capability: 0 OperVersion: 0 MaxVersion: 0 EN: 1 Will: 0 Err: 0 Logic Link Status: Up switch# none Dell Converged Enhanced Ethernet Command Reference 117 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 134
valid slot number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use : 554 TLVs discarded: 0 TLVs unrecognized: 0 See Also none 118 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 135
Defaults There are no default configurations for this command. Command Protocol LLDP mode. Modes Description Use this command to set the global system description specific system description specific to LLDP: switch(conf-lldp)#system-description Dell See Also system-name Dell Converged Enhanced - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 136
name for the LLDP. The valid values is a maximum of32 characters. Defaults By default, the host name from the switch is used. Command Protocol LLDP configuration mode Modes Description Use this command to set the global system name specific to LLDP. Usage There are no usage guidelines for this - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 137
. Specifies the type of LAG. Specifies the 802.3ad standard-based LAG. Specifies the Dell proprietary hardware-based trunking. Defaults By default, the type is set to standard. Command Interface configuration mode Modes Description Use this command to add an interface to a port-channel specified - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 138
7 channel-group See Also switch(conf-if)#channel-group 4 mode active interface port-channel 122 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 139
per specified channel-group. Usage There are no default configurations for this command. Guidelines Examples To clear the LACP counters for a specific port-channel: switch#clear lacp 10 counters See Also show lacp counters Dell Converged Enhanced Ethernet Command Reference 123 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 140
Control Protocol (LACP) counters on all port-channels. Synopsis clear lacp counters Operands none Defaults There are no default configurations the LACP counters for all port-channels. Usage There are no default configurations for this command. Guidelines Examples To clear the counters for all - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 141
event Turns on event debugging. nsm Turns on Network Services Module (NSM) debugging. pdu Turns on PDU debugging. Control Protocol (LACP). Use the no debug command to disable debugging. Usage To display debug outputs on a specific cmsh session, use the terminal monitor command. Guidelines Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 142
all switch#debug lacp pdu rx all switch#show debug lacp LACP rx debugging is on LACP tx debugging is on show debug lacp 126 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 143
command to reset the system priority to the default value. Note Lower numerical values have higher priorities. Usage There are no usage guidelines for this command. Guidelines Examples To set the LACP system-priority to 68: switch(config)#lacp system-priority 68 To clear the configured LACP - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 144
(DU). Specifies a long timeout value. Specifies a short timeout value. Defaults By default, the short timeout value is 3 seconds for Dell trunks. For standard trunks, the long timeout value is 90 seconds. Command Interface configuration mode Modes Description Use this command to set the short - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 145
that minimum number, then the port-channel is declared operationally DOWN even though it has operationally UP members. Defaults The default number of links is 1. Command Interface configuration mode Modes User Guidelines Use no minimum-links to disable this command. Example none See Also none - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 146
The range of valid values is 1-63. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the LACP packet counters on all interfaces that belong to a port-channel or a specific interface. Usage There are no usage guidelines - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 147
Displays the Link Aggregation Control Protocol (LACP) system ID and priority information. Synopsis show lacp sys-id Operands none Defaults There are no default configurations for this command. -05-1e-76-1a-a6 See Also none Dell Converged Enhanced Ethernet Command Reference 131 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 148
channel-group. Note LAG interfaces are called port-channels. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Displays the : 0 % Link: Te 0/2 (67239938) sync: 0 See Also none 132 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 149
default aging time is 300 seconds. Command Global configuration mode Modes Description Use this command to set the aging time or to add static addresses to the MAC address table. Usage The vlan keyword is mandatory because the switch only supports independent VLAN learning (IVL). Guidelines Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 150
intengigabitethernet 0/1 vlan 100 To set the aging time to 10 minutes: switch(config)#mac-address-table aging-time 600 show mac address-table static 134 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 151
-table Synopsis Operands Defaults Displays a specific MAC address table static and dynamic entry or the MAC address table static and dynamic entries for a specific interface or VLAN. 1-3583. No static addresses are configured. Dell Converged Enhanced Ethernet Command Reference 135 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 152
3333 Static Inactive Te 0/1 Total MAC addresses : 1 To display the aging time for a specific MAC address table: switch#show mac-address-table aging-time MAC Aging-time : 300 seconds -table linecard, show mac address-table count 136 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 153
". Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use no fcoe-map to revert to the default values for the map. Examples none See Also fcoeport Chapter 9 Dell Converged Enhanced Ethernet Command Reference 137 53-1002115 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 154
must be in interface mode for a selected interface. Defaults There are no default configurations for this command. Command Interface configuration mode Modes User Guidelines If the interface is configured as fcoeport, the fcoeport configuration will take precedence over the switchport mode. If - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 155
There are no usage guidelines for this command. Guidelines Example You must first enter FCoE map mode, then configure the VLAN. switch(config)#fcoe-map default switch(conf-fcoe-map)#fcoe-vlan 5 See Also fcoe-map, fcoeport Dell Converged Enhanced Ethernet Command Reference 139 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 156
map information Synopsis show fcoe-map Operands none Description Use this command to display the current FCoE map information. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 157
Media Access Control (MAC) ACL counters for all interfaces which have ACL applied on them or for a specific interface. clear Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to clear counters for all or for a specific - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 158
Access Control List Configuration mode Modes Description Usage Guidelines Use this command to configure rules to match and drop traffic based on the source and destination MAC addresses and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 159
deny (extended ACLs) 10 See Also switch(conf-macl-ext)#no deny 0022.3333.4444 0022.3333.5555 ipv4 mac-access-list extended, mac-access-list standard, permit Dell Converged Enhanced Ethernet Command Reference 143 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 160
By default, no MAC ACLs are configured. Command Feature Access Control List Configuration mode Modes Description Use this command to configure rules to match and to drop traffic based on the source MAC address. You can also enable counters for a specific rule. There are 255 ACL counters supported - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 161
the ACL is already created, this command puts the switch in the extended MAC access-list configuration mode. Use the no mac access-list extended command to remove the access list. Extended See Also deny, permit, show access-lists Dell Converged Enhanced Ethernet Command Reference 145 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 162
If ACL is already created, this command puts the switch in the standard MAC access-list configuration mode. Use the no mac access-list standard command to remove the access list. Standard ACLs Also deny, permit, show access-lists 146 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 163
access list. Specifies to filter inbound packets only. Default There are no access lists applied to the interface. Command Interface configuration mode Modes Description Use this command to apply extended, show access-lists Dell Converged Enhanced Ethernet Command Reference 147 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 164
Control List Configuration mode Modes Description Usage Guidelines Use this command to configure rules to match and to permit traffic based on the source and destination MAC addresses, and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 165
permit (extended ACLs) 10 See Also To delete a filter rule in a MAC extended ACL: switch(conf-macl-ext)#no permit 0022.3333.4444 0022.3333.5555 ipv4 mac-access-list extended, mac-access-list standard, no seq Dell Converged Enhanced Ethernet Command Reference 149 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 166
default, no MAC ACLs are configured. Command Feature Access Control List Configuration mode Modes Description Use this command to configure rules to match and to permit traffic based on the source MAC address. You can also enable counters for a specific rule. There are 255 ACL counters supported - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 167
number between rules. The range of valid values is 1-65535. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this See Also mac-access-list extended, seq Dell Converged Enhanced Ethernet Command Reference 151 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 168
to insert a rule anywhere in the MAC ACL; it configures rules to match and permits or drops traffic based on the source and destination MAC addresses, and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported per port group. Use the no seq value - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 169
0022.3333.4444 0022.3333.5555 ipv4 count To delete a rule from a MAC extended ACL: switch(conf-macl-ext)#no seq 100 deny, permit, resequence Dell Converged Enhanced Ethernet Command Reference 153 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 170
Feature Access Control List Configuration mode Modes Description Use this command to configure rules to match and permit or drop traffic based on source and destination MAC address and protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported per port - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 171
the VLAN number. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to set See Also show running-config, show statistics Dell Converged Enhanced Ethernet Command Reference 155 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 172
of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode is not written into the hardware the output displays as shown below: seq 8 permit 00c0 (unwritten) If the rule is written into the hardware, but the counters are not enabled for that rule - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 173
might become root. Use the no bridge-priority command to return to the default settings. Usage This command must be used to specify the priority of the bridge configure terminal switch(config)#protocol spanning-tree mstp switch(conf-mstp)#bridge-priority 8192 see Also protocol spanning-tree Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 174
switch(conf-mstp)#cisco-interoperability enable To disable Cisco interoperability on a switch: switch#configure terminal switch(config)#protocol spanning-tree mstp switch(conf-mstp)#cisco-interoperability disable See Also none 158 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 175
Specifies a valid slot number. Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this port-channel 23 See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 159 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 176
slot Specifies a valid slot number. port Specifies a valid port number. Defaults By default debugging is not turned on. Command Privileged EXEC mode Modes Description Use this -tree tx debugging is off Te 0/1 tx is on 160 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 177
See Also show debug spanning-tree, show debug debug spanning-tree 11 Dell Converged Enhanced Ethernet Command Reference 161 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 178
disable-timeout enable Operands none Defaults There are no default configurations for this command. Command remains in the disabled state unless the port is enabled manually. This command allows you to enable the interface from the Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 179
for the interface to time out. The range of valid values is 10-1000000. Defaults The default is 300 seconds. The timeout feature is disabled. Command Protocol Spanning Tree mode Modes 10 See Also error-disable-timeout enable Dell Converged Enhanced Ethernet Command Reference 163 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 180
and listening states. The range of valid values is 4-30. Defaults The default is 15 seconds. Command Protocol Spanning Tree mode Modes Description Examples To configure the forward-delay time to 18 seconds: switch(conf-mstp)#forward-delay 18 See Also hello-time, max age 164 Dell Converged - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 181
Defaults The default is 2 seconds. Command Protocol Spanning Tree mode Modes Description Use this command to configure to return to the default settings. Usage Guidelines When configuring the hello-time, the >=2*(hello-time + 1) Examples To configure spanning-tree bridge hello time to 5 seconds: - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 182
can be set only in increments of 4096. Defaults The default priority value is 32768. Command Protocol Spanning Tree . • VLAN instance mapping is removed from the configuration if the underlying VLANs are deleted. Examples To Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 183
-age. The range of valid values is 6-40. Defaults The default is 20 seconds. Command Protocol Spanning Tree mode Modes Description Use this command to control the maximum length of time that passes before an interface saves its configuration Bridge Protocol Data Unit (BPDU) information. Use the - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 184
The range of valid values is 1-40. Defaults The default is 20 hops. Command Protocol Spanning Tree MSTP mode Modes Description Use this command to configure the maximum number of hops for a BPDU in show spanning-tree mst 168 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 185
sets that the path-cost does not change according to port-channel's bandwidth. Defaults The default path-cost is standard. Command Protocol Spanning Tree mode Modes Description Use this path-cost standard See Also none Dell Converged Enhanced Ethernet Command Reference 169 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 186
the Spanning Tree Protocol (STP). Defaults By default, STP is not enabled. STP is not required in a loop-free topology. Command Global configuration mode Modes Description Use this command stp See Also show spanning-tree 170 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 187
no region region-name Assigns a name to an MSTP region. Defaults There are no default configurations for this command. Command Protocol Spanning Tree MSTP mode Modes Description dell1 See Also revision, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 171 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 188
255. Defaults The default is 0. Command Protocol Spanning Tree MSTP mode Modes Description Use this command to specify the configuration revision configuration revision to 1: switch(config)#protocol spanning-tree mstp switch(conf-mstp)#revision 1 See Also region, show spanning-tree 172 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 189
. Synopsis show spanning-tree Operands none Defaults There are no default configurations for this command. Command EXEC mode : Discarding Designated External Path Cost: 0; Internal Path Cost 0 Configured Path Cost: 2000 Dell Converged Enhanced Ethernet Command Reference 173 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 190
; EdgeDelay: 3 sec Configured Root guard: off; Operational : 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port ; EdgeDelay: 3 sec Configured Root guard: off; Operational : 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port ; EdgeDelay: 3 sec Configured Root guard: off; - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 191
Spanning Tree Protocol. Synopsis show spanning-tree brief Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this No See Also show spanning-tree interface Dell Converged Enhanced Ethernet Command Reference 175 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 192
valid port number. Defaults There are no default configurations for this command. : Disabled; State: Discarding Designated Path Cost: 0 Configured Path Cost: 2000 Designated Port Id: 0; Port : no; AdminEdge: no; EdgeDelay: 3 sec Configured Root guard: off; Operational Root guard: off Boundary - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 193
in brief. Synopsis show spanning-tree mst brief Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this mst interface, show spanning-tree mst instance Dell Converged Enhanced Ethernet Command Reference 177 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 194
slot number. Specifies a valid port number. Defaults There are no default configuration for this command. Command EXEC mode Modes Cost: 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port Id: 0; CIST Priority: 128 178 Dell Converged Enhanced Ethernet Command Reference 53-1002115 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 195
: 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 : 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 Designated : 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 Designated sec Configured Root guard: off - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 196
11 show spanning-tree mst detail See Also Link-type: point-to-point Received BPDUs: 0; Sent BPDUs: 0 MSTI details show spanning-tree mst interface, show spanning-tree mst instance 180 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 197
interface for which to display information on the MSPT instance. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command tree mst brief, show spanning-tree interface Dell Converged Enhanced Ethernet Command Reference 181 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 198
instance. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display MSTP protocol specific information spanning-tree brief, show spanning-tree mst brief 182 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 199
globally. Synopsis shutdown no shutdown Operands none Defaults STP is not required in a loop-free topology and is not enabled by default. Command Protocol Spanning Tree mode Modes Description )#no shutdown See Also none Dell Converged Enhanced Ethernet Command Reference 183 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 200
tree autoedge no spanning-tree autoedge Operands none Defaults Auto detection is not enabled. Command Interface configuration mode Modes Description Use this command to spanning-tree autoedge See Also protocol spanning-tree 184 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 201
Spanning Tree Protocol (STP) calculations. The range of valid values is 1-200000000. Defaults The default path cost is 200000000. Command Interface configuration mode Modes Description Use this command to configure the path cost for spanning-tree calculations. Usage Lower path cost indicates - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 202
the reception of BPDUs. Defaults Edge port is disabled. Command Interface configuration mode Modes Description Use this edge port. • Because ports directly connected to end stations cannot create bridging loops in the network, Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 203
-tree guard root no spanning-tree guard root Operands none Defaults Guard root is disabled. Command Interface configuration mode Modes Description Use this command to enable the guard guard root See Also spanning-tree cost Dell Converged Enhanced Ethernet Command Reference 187 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 204
sent by the root switch configuration messages. The range of valid values 1-10. Defaults The default is 2 seconds. Command Interface configuration mode Modes Description Use this forward-delay, max-age, show spanning-tree 188 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 205
port. Defaults The default path-cost value is 2000 on a 10 Gbps Ethernet interface. Command Interface configuration mode Modes Description Use this command to set restrictions for a port on a particular MSTP instance. Usage Use this command for MSTP-specific configurations. Guidelines Examples - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 206
Defaults The default is point-to-point. Command Interface configuration default setting of the link type. Guidelines Examples To specify the link type as shared: switch(conf-if-te-0/0)#spanning-tree link-type shared See Also spanning-tree link-type shared, no spanning-tree link-type 190 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 207
the port. Guards the port against the reception of BPDUs. Defaults Port Fast is disabled. Command Interface configuration mode Modes Description Use this command to enable the Port Fast bpdu-guard, spanning-tree autoedge Dell Converged Enhanced Ethernet Command Reference 191 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 208
Port priority is in increments of 16. Defaults The default value is 128. Command Interface configuration mode Modes Description Use this command to change configure the port priority to 16: switch(conf-if-te-0/1)#spanning-tree priority 16 See Also spanning-tree cost, show spanning-tree 192 Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 209
none Defaults The restricted role is disabled. Command Interface configuration mode Modes Description Use this command to configure the command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To configure the port from becoming a - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 210
tree restricted-tcn Operands none Defaults The restricted TCN is disabled. Command Interface configuration mode Modes Description Use this TCN on a specific interface: switch(conf-if-te-0/1)#spanning-tree restricted-tcn See Also show spanning-tree 194 Dell Converged Enhanced Ethernet Command - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 211
shutdown Operands none Defaults Spanning tree is not enabled. Command Interface configuration mode Modes Description Examples To disable spanning tree on a specific interface: switch(config)#interface intengigabitethernet 0/1 Dell Converged Enhanced Ethernet Command Reference 195 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 212
Control (MAC) address based on the optimal scheme. Synopsis spanning-tree tc-flush-standard no spanning-tree tc-flush-standard Operands none Defaults MAC address flushing is enabled. Command Global configuration -tree brief 196 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 213
BPDUs than can be sent before pausing for 1 second. The range of valid values is 1-10. Defaults The default is 6. Command Protocol Spanning Tree MSTP mode Modes Description Use this command to configure the BPDU burst size by changing the transmit hold count value. Use the no transmit-holdcount - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 214
11 transmit-holdcount 198 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 215
the snooping configuration related information. The range of valid values is 1-3583. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes Description Use this command to clear the group information in the IGMP database, including entries for either a specific group - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 216
12 clear ip igmp group See Also none 200 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 217
in the IGMP protocol module. Synopsis clear ip igmp groups Operands none Defaults There are no defaults for this command. Command Privileged EXEC mode Modes Description Use this command #clear ip igmp groups See Also none Dell Converged Enhanced Ethernet Command Reference 201 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 218
vlan_id Specifies which VLAN interface to display the snooping configuration related information. The range of valid values is 1- IGMP packets received and sent, and IGMP-host related events. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 219
in milliseconds. Valid range is 1000 to 25500 milliseconds. Default value is 1000 milliseconds. Description The last member query interval waits to receive a response to a group query message. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 220
Response time in seconds. Valid range is 1 to 18000 seconds. Default value is 125 seconds. Description The query interval is the amount of in seconds between IGMP query messages sent by the switch. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 221
seconds seconds Response time in seconds. Valid range is 1 to 25 seconds. Default value is 10 seconds. Description When a host receives the query packet, , provided that no other host has responded yet. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 222
for all VLAN interfaces. Synopsis ip igmp snooping enable no ip igmp snooping enable Operands none Defaults IGMP snooping is globally disabled. Command Global Configuration mode Modes Description Use this command to enable or disable the Internet Group Management Protocol (IGMP) snooping - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 223
enable Operands none Defaults When snooping is enabled globally, IGMP snooping enabled on all VLAN interfaces. Command Interface Configuration mode Modes Description Use this command to enable or disable the Internet Group Management Protocol (IGMP) snooping on a specific VLAN interface. Usage - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 224
leave processing allows the removal of an interface from the forwarding-table without sending out group specific queries to the interface. Defaults This mode is disabled by default. Command Global Configuration mode Modes User Guidelines Use no ip igmp snooping fast-leave to disable this function - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 225
igmp snooping mrouter Configures a VLAN port Defaults There are no default configurations for this command. Command Privileged EXEC Mode Modes Description Use this command to configure this command to return to the default setting. Guidelines Examples To configure a VLAN port member to be - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 226
Configures the mrouter-time-out ip igmp snooping mrouter-timeout seconds seconds Timeout time in seconds. Valid range is 1 to 60000 seconds. Default for when multicast router ports are automatically learned. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 227
the VLAN. Use the no ip igmp snooping querier enable command to return to the default setting. Usage Use no ip igmp snooping querier enable to disable this command. Guidelines ip igmp interface, show ip igmp snooping interface Dell Converged Enhanced Ethernet Command Reference 211 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 228
12 ip igmp static-group ip igmp static-group Synopsis Configures the static group membership entries. ip igmp static-group A.B.C.D { are automatically added to the IGMP cache and mroute table. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 229
as related events. Synopsis show debug ip igmp Operands none Description This command displays the IGMP packets received and transmitted. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are no user guidelines for this command. Example none - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 230
There are no defaults for this command. Command Privileged EXEC mode Modes Description Use this command to display the IGMP database, including configured entries for either all groups on all interfaces, or all groups on specific interfaces, or specific groups on specific interfaces. Usage There - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 231
VLAN interface to display the snooping configuration related information. The range of valid values is 1-3583. Defaults There are no defaults for this command. Command Privileged ip igmp snooping interface vlan 5 See Also none Dell Converged Enhanced Ethernet Command Reference 215 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 232
none Description This command displays the IGMP contents of the currently running configuration. Note that this information may differ from the contents of the actual running-config file. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 233
defaults for this command. Command Interface Mode Modes Description Use this command to identify the sFlow collectors to which sFlow datagrams are forwarded. Use the no sflow collector ip-address command to reset See Also none Dell Converged Enhanced Ethernet Command Reference 217 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 234
default, sFlow is disabled on the system. Command Global configuration mode Modes Description Use this command to enable sFlow globally. Use the no sflow enable command to disable sFlow globally. Usage This command is supported on physical ports and Link Aggregation Group (LAG) ports. Guidelines - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 235
enable interface no sflow enable interface Operands none Defaults By default, sFlow is disabled on all interfaces. Command Interface supported on physical ports and Link Aggregation Groups (LAG) ports. After a Guidelines physical port is a member of a LAG, it inherits the sFlow configuration - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 236
set the polling interval. The range of valid values is 1-65535. Defaults The default global counter polling interval value is 20 seconds. Command Global configuration mode Modes Description Use this command to configure the polling interval globally. The interval is the maximum number of seconds - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 237
in seconds to set the polling interval. The range of valid values is 1-65535. Defaults The default counter polling interval value is 20 seconds. Command Interface Mode Modes Description Use this command to configure the polling interval for an interface. The interval is the maximum number of - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 238
Global configuration mode Modes Description Use this command to change the current global default sampling rate. Usage Guidelines Sample-rate is the average number of packets skipped before the sample is taken. sFlow does not have time-based sampling. If the value entered is not a correct power - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 239
sampling rate for a specific interface. Usage Guidelines This command changes the sampling rate for an interface. By default, the sampling rate of an interface is set to the same value as the current global default sampling rate. If the value entered is not a correct power of 2, the command - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 240
no usage guidelines for this command. Guidelines Examples To display sFlow statistics: switch#show sflow sFlow services are enabled Global default sampling rate: 32768 Global default counter polling interval: 20 1 collectors configured Collector IP addr: 172.21.162.51, Agent IP addr: 10.32.152.22 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 241
on a specific interface. show sflow interface name interface name Specifies the name of the interface. Defaults By default, sFlow is 1/16 Configured sampling rate :8192 Actual sampling rate :8192 Counter polling interval :15 Samples rcvd from h/w :33 See Also show sflow Dell Converged - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 242
13 show sflow interface 226 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 243
the Port Mirroring session, displayed in the running-config file. Defaults none Command Monitor session mode Modes User Guidelines Use this command to 1 sw0(config-mon-sess-1)#description server group 1 switch-cmsh See Also monitor session Dell Converged Enhanced Ethernet Command Reference 227 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 244
both Specifies to monitor transmitting and receiving traffic. Defaults There are no default configurations for this command. Command Modes Description Privileged EXEC 0/1 destination extengigabitethernet 0/15 direction both 228 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 245
identification number. The range of valid values is 0-65535. Defaults There are no default configurations for this command. Command Exec Mode Modes Description Use sessions: switch#show monitor See Also monitor session Dell Converged Enhanced Ethernet Command Reference 229 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 246
14 show monitor 230 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 247
of valid values is 1-65535. owner name Specifies the identity of the owner. The maximum number of characters is 32. Defaults There are no alarms configured. Command Global configuration mode Modes Description Use this command to set alarm conditions. Use the no rmon alarm command to disable the - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 248
15 rmon alarm See Also switch(config)#rmon alarm 100 1.3.6.1.2.1.16.1.1.1.5.65535 interval 5 absolute rising-threshold 10000 event 100 falling-threshold 1000 event 101 owner admin rmon event, show rmon 232 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 249
collection history number number Specifies the RMON collection control index value. The range of valid values characters is 32. Defaults The collection of RMON history is not enabled. Command Interface configuration mode Modes Description history Dell Converged Enhanced Ethernet Command Reference 233 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 250
control index value. The range of valid values is 1-65535. Specifies the identity of the owner. Defaults The collection of RMON statistics is not enabled. Command Interface configuration admin See Also show rmon statistics 234 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 251
or string name to identify this trap. Defaults There are no events configured. Command Global configuration mode Modes Description Use this command to to remove the event configuration. Usage There are no usage guidelines for this command. Guidelines Examples To configure an RMON event: switch - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 252
values is 1-65535. Specifies a brief summary of the output. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this byte pkts: 0 Over 1518-byte pkts(Oversize - Jumbo): 0 236 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 253
"My Description" Event type Log & SnmpTrap Event community name admin Last Time Sent = 00:00:00 Owner admin rmon alarm, rmon event 15 show rmon Dell Converged Enhanced Ethernet Command Reference 237 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 254
no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines Use the statistics option to display the detailed history. Example To display the RMON history: switch#show rmon history RMON history control entry 1 interface: ifIndex.1745682445 InTengigabitEthernet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 255
default no cee Operands default Only a single map name, called default, is allowed. Defaults There is no CEE Provisioning applied on an interface. Command Interface configuration CEE map on an interface: switch(conf-if-te-0/1)#cee default Because the switch does not allow applying a CEE map that - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 256
configuration mode. Synopsis cee-map default no cee-map Operands default The CEE map name. Defaults There is no default value for this command. Command Global configuration mode Modes Description Only a single CEE map is allowed, named "default map to revert to the default values for the map. - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 257
Control (PFC) for each priority that gets mapped to the Priority Group. Defaults There is no default value for the weight. The PFC is disabled. Command CEE map configuration mode Modes Description Use this command to configure Dell Converged Enhanced Ethernet Command Reference 241 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 258
Defaults The default CEE Priority mapping table matches the IEEE 802.1Q recommendation for systems supporting Class 7 (PGID 15.0). Command CEE Map Configuration mode Modes Description Use this command to provision the 242 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 259
incoming Priority-to-Priority Groups PGID 1 1 15.0 See Also switch(config)#ceemap test switch(conf-ceemap)#priority-table 1 1 0 1 1 1 1 15.0 cee, cee-map, priority-group-table Dell Converged Enhanced Ethernet Command Reference 243 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 260
Service (CoS) value. qos cos value no qos cos value Specifies the CoS value. The range of valid values is 0-7. Defaults The default CoS value is 0 (zero). Command Interface configuration mode, then the Interface Default CoS value is applied the CoS value to the default. Usage If the interface - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 261
CoS mutation map. Defaults There is no explicit CoS-to-CoS mutation QoS map applied; by default the inbound CoS equals the outbound CoS. Command Interface configuration mode Modes Description Use cos-mutation, show qos maps Dell Converged Enhanced Ethernet Command Reference 245 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 262
removed before a new one can be applied. Defaults There is no explicit CoS-to-Traffic Class QoS map .1Q recommendations for systems supporting eight Traffic Classes. Command Interface configuration mode Modes Description Use Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 263
mutation QoS map already exists then, it is updated and new mapping is automatically propagated to all interfaces CoS 7. Defaults There are no CoS-to-CoS mutation QoS maps defined. Command Global configuration mode Modes Dell Converged Enhanced Ethernet Command Reference 247 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 264
16 qos map cos-mutation See Also qos cos-mutation, show qos maps 248 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 265
already exists, then it is updated and new mappings are automatically configured interface QoS trust, interface default CoS, and CoS-to-CoS mutation policies. Traffic Class is a reference to a scheduler queue and packet servicing default behavior recommended in IEEE 802.1Q for systems supporting - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 266
The default weight value is 25 percent bandwidth for each multicast Traffic Class. Command Global configuration mode Modes Description Use this command to configure the multicast Traffic Class packet expansion scheduler policy. All multicast Traffic Class packet expansion queues are serviced - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 267
bandwidth, and Traffic Class 3 getting 40 percent bandwidth: switch(config)#qos queue multicast scheduler dwrr 10 20 30 40 To return the system to the default multicast Traffic Class packet expansion scheduler policy: switch(config)#no qos queue multicast scheduler See Also qos rcv-queue multicast - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 268
no qos queue scheduler strict-priority Configures the Strict Priority Traffic Class policy. All Strict Priority Traffic Classes are serviced before any DWRR Traffic Classes. strict The range of valid values is 0-100 percent. 252 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 269
no default value for each weight value. Command Global configuration mode Modes Description Use this command to configure the Traffic Class packet scheduler policy. Eight Traffic Classes are supported with a configurable number of them being Strict Priority and any remaining ones being serviced - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 270
Configures -20000000 pkt/s. Configures a cap on Defaults The default burst size is 4096 packets. The default rate value is 3000000pkt/s. Command Global configuration mode Modes Description Use this command to configures limit to the default settings. Usage system to the default multicast packet - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 271
Operands Configures a Defaults The default is 64 packets for each multicast Traffic Class. Command Global configuration mode Modes Description Use this command to configure expansion queques to the default value. Usage There are the system to the default multicast packet expansion Tail Drop - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 272
Defaults The QoS trust CoS mode set to the untrusted state. Command Interface configuration controls user priority mapping of incoming traffic. The untrusted mode overrides all incoming priority markings with the Interface Default Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 273
. For each CEE map, the configuration state is displayed with a list of all of the Layer 2 interfaces bound to the CEE map. Usage Fabric OS v6.3.1_cee only allows the CEE map name "default." Guidelines Examples none See Also cee, cee-map Dell Converged Enhanced Ethernet Command Reference 257 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 274
number within the chassis. Specifies the ASIC number within the linecard. all Reports QoS flow control statistics for all interfaces within the system. Command EXEC mode Modes Description Use this command to display all of the configured flow control information for a specific interface. Usage - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 275
See Also 3 Off Off Off Off 4 Off Off Off Off 5 Off Off Off Off 6 Off Off Off Off 7 Off Off Off Off show qos interface, show cee maps show qos flowcontrol interface 16 0 0 0 0 0 Dell Converged Enhanced Ethernet Command Reference 259 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 276
an ASIC. Specifies the ASIC linecard slot number within the chassis. Specifies the ASIC number within the linecard. all Reports QoS configurations for all interfaces within the system. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 277
129761 129761 129761 129761 129761 Flow control mode PFC CoS2 TX on, RX 64 64 64 64 64 64 64 Traffic Class Scheduler configured for 0 Strict Priority queues TrafficClass: 0 1 2 25 25 25 25 25 25 cee-map, priority table Dell Converged Enhanced Ethernet Command Reference 261 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 278
default behavior without any specified operands is to report on all defined QoS maps. Command EXEC mode Modes Description Use this command to display information on the QoS defined maps. For each QoS map, the configuration 262 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 279
Bytes TC Packets Bytes 0 680458 87098624 0 0 0 1 0 0 1 32318 0 2 0 0 2 0 0 3 0 0 3 0 0 4 0 0 4 0 0 5 0 0 5 0 0 6 0 0 6 0 0 7 0 0 7 0 0 See Also qos maps, cee-map Dell Converged Enhanced Ethernet Command Reference 263 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 280
a valid port number. all Reports QoS configurations for all 10 Gbps Ethernet interfaces within 2 Priority, Traffic Class Mapping, Congestion Control, and the Scheduler policy. Usage There See Also show qos rcv-queue multicast 264 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 281
queueing statistics for all ASICs within the system. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use 2 TC 3 0/0 0 0 0 0 See Also show qos rcv-queue interface Dell Converged Enhanced Ethernet Command Reference 265 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 282
16 show qos rcv-queue multicast 266 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 283
all dot1x statistics. Synopsis clear dot1x statistics Operands none Defaults There are no defaults for this command. Command Privileged EXEC mode Modes clear dot1x statistics See Also clear dot1x statistics interface Dell Converged Enhanced Ethernet Command Reference 267 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 284
interface. Specifies a valid slot number. Specifies a valid port number. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes Description Use this command to clear all of the dot1x statistics for a specific interface port. Usage There are no usage guidelines for - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 285
17 dot1x authentication Enables dot1x on a port. Synopsis dot1x authentication no dot1x authentication Operands none Defaults There are no defaults for this command. Command Interface configuration mode Modes Description Use this command to enable dot1x on a port. Use the no dot1x - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 286
dot1x enable no dot1x enable Operands none Defaults By default, authentication is disabled globally. Command Global configuration mode Modes Description Use this command to : switch(config)#dot1x enable See Also none 270 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 287
port to remain in an unauthorized state. Defaults The default port state is auto. Command Interface configuration mode Modes Description Use this command to control the authorization of a port state. Use the no dot1x port-control command to return to the default setting. Usage There are no usage - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 288
range of valid values is 1-65535. Defaults The default time is 60 seconds. Command Interface configuration mode Modes Description Use this command to Changing the quiet-period interval time to a number lower than the default can result in a faster Guidelines response time. Examples To change - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 289
valid slot number. port Specifies a valid port number. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes Description Use reauthenticate interface extengigabitethernet 0/16 See Also none Dell Converged Enhanced Ethernet Command Reference 273 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 290
Synopsis dot1x reauthentication Operands none Defaults There are no defaults for this command. Command Interface configuration mode Modes Description Use this switch(conf-if-te-0/16)#dot1x reauthentication See Also none 274 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 291
values is 1-10. Defaults The default number of times that a port attempts authentication is two. Command Interface configuration mode Modes Description Use this reauthMax 5 To set the reauthentication maximum to the default value: switch(config)#interface extengigabitethernet 0/16 switch(conf- - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 292
The range of valid values is 1-4294967295. Defaults The default time is 3600 seconds. Command Interface configuration mode Modes Description Use this command to set the -te-0/16)#dot1x timeout re-authperiod 25 See Also none 276 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 293
authentication server. The range of valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode server transmission time: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout server-timeout 40 See Also none Dell - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 294
EAP frame. The range of valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode Modes Description Use this command to specify the EAP response supp-timeout 40 See Also none 278 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 295
attempts. The range of valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode Modes Description Use this command to set the interval dot1x timeout tx-period 34 See Also none Dell Converged Enhanced Ethernet Command Reference 279 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 296
dot1x on the system. Synopsis show dot1x Operands none Defaults There are no defaults for this command. Command EXEC mode Modes Description Use Protocol Version: 2 Auth Server: RADIUS RADIUS Configuration Position: Server Address: Port: Secret: Position: Server Address: Port: Secret: - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 297
dot1x all Operands none Defaults There are no defaults for this command. Command Configuration Position: Server Address: Port: Secret: 1 172.21.162.51 1812 sharedsecret Position: Server Address: Port: Secret: 2 10.32.154.113 1812 sharedsecret 802.1X info for interface te0/16 Port Control - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 298
17 show dot1x all See Also none 282 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 299
Specifies a valid slot number. port Specifies a valid port number. Defaults There are no defaults for this command. Command EXEC mode Modes Description Use this command to BackendAuthSuccess: 0 BackendAuthFails: 0 See Also none Dell Converged Enhanced Ethernet Command Reference 283 53- - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 300
a valid port number. Defaults There are no defaults for this command. Command .1X info for interface te0/16 Port Control: Auto Port Auth Status: Unauthorized Protocol Quiet Period: 60 seconds Supplicant Timeout: 30 seconds Server Timeout: 30 seconds Re-Auth Interval: 3600 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 301
a valid slot number. port Specifies a valid port number. Defaults There are no defaults for this command. Command EXEC mode Modes Description Use this command 34 secs Terminate Cause: Not terminated yet See Also none Dell Converged Enhanced Ethernet Command Reference 285 53-1002115-01 - Dell PowerEdge M420 | Dell Converged Enhanced Ethernet Command Reference - Page 302
a valid slot number. port Specifies a valid port number. Defaults There are no defaults for this command. Command EXEC mode Modes Description Use this command Rx: 0 - EAPOL Last Frame Src: 0000.0000.0000 See Also none 286 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01
53-1002115-01
07 December 2010
Dell Converged Enhanced
Ethernet Command
Reference