Dell and the Dell logo are trademarks of Dell Inc. Dell 10GbE Pass Through Module (XAUI) User Manual P/N: M1601P Rev 1.0 - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 2
reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc.; Other trademarks and trade names may be used in this document to - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 3
2.4 LED Indicators 2.4.1 System LEDs 2.4.2 Port LEDs 2.4.3 Installation Safety Warnings 2.4.4 Mechanical Installation 2.4.5 Cable Installation Chapter 3 Troubleshooting Appendix A Specifications A.1 Mechanical Drawing with Dimensions Appendix B Supported Optical Modules and DCAs Appendix C EMC - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 4
Rev 1.0 Related Documentation The documentation set accompanying the Pass Through Module includes the following: Table 1 - Reference Documents and Web Sites Firmware and Firmware Update Tools Dell Pass Through Module Software User Manual Latest Supported Cables and Optical Modules 4 - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 5
-10GbE PTM About this Manual Rev 1.0 This User Manual is for the Dell 10Gb Ethernet Pass Through II passs through module. This manual describes the installation and basic use of Dell 10GbE 16 port Pass Through Module for blade servers. Intended Audience This manual is intended for users and system - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 6
Rev 1.0 1 Overview Overview The PTM is an I/O module designed for the PowerEdge M1000e Dell Chassis. The product provides 10Gigabit connectivity for blade servers to Ethernet LANs. The product supports the following Ethernet protocols. Table 2 - Protocols Physical Connections Pass Through II - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 7
Dell -10GbE PTM • System status LEDs: Power Supply, Status Rev 1.0 1.2 Serial Number and Product Version Information The serial number and product version information are found on the label seen in the figure below. - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 8
Pass Through Module Before you install your new PTM, unpack it and make sure that there is no visible damage that may have occurred during shipping. Your package should contain the following items: • Dell -10GbE Pass Through Module for Blade Servers • This User's Manual The PTM is shipped without - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 9
supports hot-removal. It may be removed when the chassis is powered on or off. The PTM must not be removed during a firmware update process. Note: Firmware update work. See Supported Optical Modules and DCAs on page 17 for lists of approved DCAs and optical modules. 2.3.2 Installation and Removal of - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 10
panel. The green LED, when lit, indicates that the driver is running and a valid physical connection between nodes exists. If the green LED is blinking, it indicates a problem with the physical link. The yellow LED when lit, indicates a valid data activity link, this is the logical link. The yellow - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 11
Dell -10GbE PTM Rev 1.0 ignated by a constant yellow LED indication. A valid data activity link with data transfer is designated by a logical link BLINKING OFF Problem with the physical link No logical link ON ON Physical link up Logical link up, no data transfer ON BLINKING Physical link - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 12
Installation Safety Warnings 1. Installation Instructions Read all installation instructions before connecting the equipment to the power source for special warnings and instructions. 5. Equipment Installation This equipment should be installed, replaced, or serviced only by trained and - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 13
. 3. Pull the PTM out of the chassis. 2.4.5 Cable Installation All cables can be inserted or removed with the unit powered on. To insert a cable, press the connector into the port amount. Make sure that the weight of the cable is supported on its own and not hanging from the pass through module. 13 - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 14
Rev 1.0 3 Troubleshooting Troubleshooting As soon as a pass through module is plugged in make sure that the status LED shows green. The power LED for the pass through module shuts off: 1. Check that the there is adequate ventilation. 2. Make sure that there is nothing blocking the front or - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 15
Air Flow: 3CFM @ 30oC ambient temperature 9CFM @ 40oC ambient temperature Power through SFP+: max 1W per port Protocol Support Regulatory Compliance Ethernet: IEEE 802.3ae 10Gigabit Ethernet Blade Servers to support PTM (Internal IEEE 802.3ap Ethernet Operation Links): over Electrical Backplanes - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 16
Rev 1.0 Appendix A.1: Mechanical Drawing with Dimensions Figure 7: Mechanical Drawing 24.7 23.0 5.5 2.9 16 - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 17
PTM Rev 1.0 Appendix B: Supported Optical Modules and DCAs The following cables and optical modules are approved for the Dell PTM Table 5 - DCA (Direct attached SFP+ cables) DPN Reference Length (m) Speed K585N SFP-H10GB-CU1M 1 J564N SFP-H10GB-CU3M 3 H603N SFP-H10GB-CU5M 5 G840N - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 18
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 19
Dell -10GbE PTM Appendix C.2: ICES Statements (Canada) Class A Statement: "This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 20
Rev 1.0 Appendix C.4.1: Translation: "Class A Device This device is registered for EMC requirements for industrial use. The seller or buyer should be aware of this. If this type was sold or purchased by mistake, it should be replaced with a residential-use type. " 20 - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 21
Dell -10GbE PTM Appendix D: Interface Connector Pinouts Rev 1.0 Appendix D.1: SFP+ Interface Figure 8: Transmitter Disable. Laser output disabled on high or open. c 4 SDA 2-wire Serial Interface Data Line d 5 SCL 2-wire Serial Interface Clock Line d 6 MOD_ABS Module Absent. Grounded within - Dell PowerEdge M420 | Dell 10GbE Pass Through Module (XAUI) User Manual - Page 22
Pin Symbol Name Description 15 VccR Receiver Power Supply 16 VccT Transmitter Power Supply 17 VeeT Transmitter Ground (Common with Receiver Ground) a 18 TD+ Transmitter Non-Inverted DATA in. AC Coupled. 19 TD- Transmitter Inverted DATA in. AC Coupled. 20 VeeT Transmitter Ground