Dell PowerEdge M600 Fabric OS Command Reference Manual Supporting Fabric - Page 929
F_Ports connected to an Access Gateway, E_Ports connected to EX_Ports
View all Dell PowerEdge M600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 929 highlights
spinFab 2 Operands • F_Ports connected to an HBA. The following ports do not support the spinFab test: • Interchassis links (ICL) ports • F_Ports connected to an Access Gateway • EX_Ports • E_Ports connected to EX_Ports • If Access Gateway mode is enabled, spinFab tests only the F_Ports connected to Brocade-branded HBAs and skips all other ports (F_Ports connected to non-Brocade branded HBAs and N_Ports). When trunk groups are present, the entire trunk group must be included in the range of ports to test or false failure notifications may occur. If multiple ISL links are present between two switches that support trunking, then it is likely that trunk groups are present and all ports between the two switches should be tested at the same time. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. This command has the following operands: -nmegs count Specifies the number of frames to send in millions. The test progresses until the specified number of frames has been transmitted on each port. The default value is 10 million frames. This command only approximately counts the frames and the actual number of frames sent will be slightly larger, particularly at link speeds of 4 Gbps or higher. -ports itemlist Specifies a list of user ports to test. By default, all of the ISL ports in the current switch are tested. Refer to itemList for further details. -setfail mode Instructs spinFab how to mark failed ports. Valid values are: 0 Does not mark failing ports as FAILED (default). This option minimizes the impact on live fabrics. 1 -fports flag Marks the failing ports as FAILED. In test or qualification environments without live traffic, this may be useful with large values of -nmegs count. This mode is disabled by default. Instructs spinFab to include or exclude F_Ports in the testing. This feature is disabled by default. If enabled, spinFab tests the F_Ports connected to Brocade-branded HBAs along with other valid ports (E-ports & Loopback ports) . The HBA must be running firmware v2.1.1or higher. Valid flag values are: 0 Does not include F_Ports in the port list for testing (default). 1 Includes F_Ports in the port list for testing. Fabric OS Command Reference 897 53-1001764-02