Dell PowerEdge M600 Fabric OS Message Reference - Page 623
SEC-1202, Severity, Message, Probable Cause, Recommended, Action, supportFtp, supportSave
View all Dell PowerEdge M600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 623 highlights
90 SEC-1202 Severity INFO SEC-1202 Message , [SEC-1202], ,, INFO, , Security violation: Unauthorized access from MS device node name , device port name . Probable Cause Indicates a management server (MS) security violation was reported. The unauthorized device specified in the message attempted to establish a connection. Recommended Action Check the MS server policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy. If the MS policy does not allow the connection, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1203 Message , [SEC-1203], ,, INFO, , Login information: Login successful via TELNET/SSH/RSH. IP Addr: Probable Cause Indicates the IP address of the remote station logging in. Recommended No action is required. Action Severity INFO SEC-1250 Message , [SEC-1250], ,, WARNING, , DCC enforcement API failed: err=, key= Probable Cause Indicates an internal error caused the DCC policy enforcement to fail. Recommended Action Retry the failed security command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1251 Message , [SEC-1251], ,, ERROR, , Policy to binary conversion error: . Fabric OS Message Reference 547 53-1001767-01