SWCH-1019, Indicates the standby control processor CP does not support links to AG running QOS.
View all Dell PowerEdge M610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 704 highlights
98 SWCH-1019 SWCH-1019 Message , [SWCH-1019], ,, INFO, , Device tries to flogi, reject FLOGI as persistent PID is set on device and port has user area bound to it. Probable Cause Indicates a WWN-PID and PortAddress binding collision. Recommended Action The Peristent PID is set on the device and requested area cannot be assigned because it is user bound to a different port. Remove the WWN-PID binding or remove portAddress binding and re-enable the port and then run the wwnaddress --unbind wwn command or the portaddress --unbind slot/port command. Severity INFO SWCH-1020 Message , [SWCH-1020], ,, WARNING, ,HA state out of sync: Standby CP (ver = ) does not support QOS links to AG(Active CP version = ). Probable Cause Indicates the standby control processor (CP) does not support links to AG running QOS. Recommended Load a firmware version on the standby CP that supports QOS links to AG, using the Action firmwareDownload command. Severity WARNING SWCH-1021 Message , [SWCH-1021], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Dynamic area on default switch (Active CP version = ). Probable Cause Indicates the standby control processor (CP) does not support dynamic area on default switch. Recommended Load a firmware version on the standby CP that supports dynamic area on default switch, using the Action firmwareDownload command. Severity WARNING 628 Fabric OS Message Reference 53-1001767-01