Airborne Contaminant Level, 54 Grms at 10 Hz to 250 Hz for 15 min
View all Dell PowerEdge M820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Operating Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m above 900 m (1 °F per 550 ft). NOTE: For information on supported expanded operating temperature range and configurations, see support.dell.com/manuals. Storage Relative humidity Operating Storage Maximum vibration Operating Storage Maximum shock Operating Storage Altitude Operating -40 °C to 65 °C (-40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour 20% to 80% (noncondensing) at a maximum wet bulb temperature of 29 °C (84.2 °F) 5% to 95% (noncondensing) at a maximum wet bulb temperature of 38 °C (100.4 °F) 0.26 Grms at 5 Hz to 350 Hz for 15 min 1.54 Grms at 10 Hz to 250 Hz for 15 min One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for up to 2.6 ms Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms -15.2 m to 3048 m (-50 ft to 10,000 ft) NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1 ºF/550 ft. Storage Airborne Contaminant Level Class -15.2 m to 10,668 m (-50 ft to 35,000 ft) G1 as defined by ISA-S71.04-1985 11