Section |
Page |
About Your System |
11 |
Accessing System Features During Startup |
11 |
Front-Panel Features and Indicators |
12 |
Figure 1-1. Front-Panel Features and Indicators (Eight-Hard-Drive System) |
12 |
Figure 1-2. Front-Panel Features and Indicators (Twelve-Hard-Drive System) |
14 |
LCD Panel Features (Optional) |
16 |
Figure 1-3. LCD Panel Features |
16 |
Home Screen |
17 |
Setup Menu |
18 |
View Menu |
18 |
Hard-Drive Indicator Patterns |
19 |
Figure 1-4. Hard-Drive Indicators |
19 |
Back-Panel Features and Indicators |
20 |
Figure 1-5. Back-Panel Features and Indicators |
20 |
Guidelines for Connecting Optional External Devices |
23 |
NIC Indicator Codes |
23 |
Figure 1-6. NIC Indicators |
23 |
Power Indicator Codes |
24 |
Figure 1-7. Power Supply Status Indicator |
24 |
Diagnostic Lights (Optional) |
25 |
Table 1-1. Diagnostic Indicator Codes |
25 |
LCD Status Messages (Optional) |
27 |
Solving Problems Described by LCD Status Messages |
39 |
Removing LCD Status Messages |
39 |
System Messages |
40 |
Warning Messages |
55 |
Diagnostics Messages |
55 |
Alert Messages |
55 |
Other Information You May Need |
56 |
2 |
57 |
Using the System Setup Program and UEFI Boot Manager |
57 |
Choosing the System Boot Mode |
57 |
Entering the System Setup Program |
58 |
1 Turn on or restart your system. |
58 |
2 Press <F2> after you see the following message: |
58 |
Responding to Error Messages |
58 |
Using the System Setup Program Navigation Keys |
58 |
System Setup Options |
59 |
Main Screen |
59 |
Figure 2-1. System Setup Program Main Screen |
59 |
Memory Settings Screen |
61 |
Processor Settings Screen |
61 |
SATA Settings Screen (Optional) |
62 |
Boot Settings Screen |
63 |
Integrated Devices Screen |
64 |
PCI IRQ Assignments Screen |
65 |
Serial Communication Screen |
65 |
Embedded Server Management Screen |
66 |
Power Management Screen |
67 |
System Security Screen |
67 |
Exit Screen |
69 |
Entering the UEFI Boot Manager |
70 |
1 Turn on or restart your system. |
70 |
2 Press <F11> after you see the following message: |
70 |
Using the UEFI Boot Manager Navigation Keys |
70 |
UEFI Boot Manager Screen |
71 |
UEFI Boot Settings Screen |
71 |
System Utilities Screen |
72 |
System and Setup Password Features |
72 |
Using the System Password |
72 |
Assigning a System Password |
72 |
1 Verify that Password Status is Unlocked. |
73 |
2 Highlight the System Password option and press <Enter>. |
73 |
3 Type your new system password. |
73 |
4 Press <Enter>. |
73 |
5 To confirm your password, type it a second time and press <Enter>. |
73 |
6 Either reboot the system now for the password protection to take effect or continue working. |
73 |
Using Your System Password to Secure Your System |
73 |
1 Turn on or reboot your system by pressing <Ctrl><Alt><Delete>. |
73 |
2 Type your password and press <Enter>. |
73 |
1 Turn on or reboot your system by pressing <Ctrl><Alt><Delete>. |
74 |
2 Type your password and press <Ctrl><Enter>. |
74 |
Disabling the System Password |
74 |
Changing an Existing System Password |
74 |
1 Enter the System Setup program by pressing <F2> during POST. |
74 |
2 Select the System Security screen. |
74 |
3 Verify that the Password Status is Unlocked. |
74 |
4 Type the new system password in the two password fields. |
74 |
Using the Setup Password |
75 |
Assigning a Setup Password |
75 |
Operating With a Setup Password Enabled |
75 |
Deleting or Changing an Existing Setup Password |
76 |
1 Enter the System Setup program and select System Security. |
76 |
2 Highlight Setup Password, press <Enter> to access the setup password window. Press <Enter> twice to clear the existing setup password. |
76 |
3 If you want to assign a new setup password, perform the steps in \ |
76 |
Embedded System Management |
76 |
Baseboard Management Controller Configuration |
77 |
Entering the BMC Setup Module |
77 |
1 Turn on or restart your system. |
77 |
2 Press <Ctrl><E> when prompted after POST. |
77 |
iDRAC6 Configuration Utility |
78 |
Entering the iDRAC6 Configuration Utility |
78 |
1 Turn on or restart your system. |
78 |
2 Press <Ctrl><E> when prompted during POST. |
78 |
3 |
79 |
Installing System Components |
79 |
Recommended Tools |
79 |
Inside the System |
79 |
Figure 3-1. Inside the System (Eight-Hard-Drive System) |
80 |
Figure 3-2. Inside the System (Twelve-Hard-Drive System) |
81 |
Front Bezel (Optional) |
82 |
Removing the Front Bezel |
82 |
1 Using the system key, unlock the bezel. |
82 |
2 Lift the release latch next to the key lock. |
82 |
3 Rotate the left end of the bezel away from the front panel. |
82 |
4 Unhook the right end of the bezel and pull the bezel away from the system. |
82 |
Figure 3-3. Removing and Replacing the Front Bezel |
82 |
Installing the Front Bezel |
83 |
1 Hook the right end of the bezel onto the chassis. |
83 |
2 Fit the free end of the bezel onto the system. |
83 |
3 Secure the bezel with the keylock. See Figure 3-3. |
83 |
Opening and Closing the System |
83 |
Opening the System |
83 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. |
83 |
2 If applicable, remove the front bezel. See \ |
83 |
3 Rotate the latch release lock on the system cover counter clockwise to the unlocked position. See Figure 3-4 and Figure 3-5. |
83 |
4 Lift the latch on top of the system and slide the cover back. |
83 |
5 Grasp the cover on both sides and lift the cover away from the system. See Figure 3-4 and Figure 3-5. |
83 |
Figure 3-4. Removing and Replacing the System Cover (Eight-Hard-Drive System) |
84 |
Figure 3-5. Removing and Replacing the System Cover (Twelve-Hard-Drive System) |
85 |
Closing the System |
85 |
1 Lift the latch on the system cover. |
85 |
2 Place the cover onto the chassis and offset it slightly back so that the two hooks on the back edge of the cover fit the corresponding tabs on the back edge of the chassis. See Figure 3-4 and Figure 3-5. |
85 |
3 Slide the cover towards the front of the chassis and press down the latch. |
85 |
4 Rotate the latch release lock in the clockwise direction to secure the cover. |
85 |
5 Reconnect the system and peripherals to their electrical outlets, and turn on the system. |
85 |
Cooling Shroud |
86 |
Removing the Cooling Shroud |
86 |
1 Open the system. See \ |
86 |
2 Grasp and gently lift the shroud up and away from the system board. See Figure 3-6. |
86 |
Figure 3-6. Removing and Installing the Cooling Shroud |
86 |
Installing the Cooling Shroud |
87 |
1 Align the shroud using the center of the numbered fan bays as a guide. |
87 |
2 Press the cooling shroud down into the chassis. |
87 |
3 Close the system. See \ |
87 |
4 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
87 |
Hard Drives |
87 |
Removing a Hard-Drive Blank |
87 |
1 If applicable, remove the front bezel. See \ |
87 |
2 Grasp the front of the hard-drive blank, press the release lever on the right side, and slide the blank out until it is free of the drive bay. See Figure 3-7. |
87 |
Figure 3-7. Removing and Installing a Hard-Drive Blank |
88 |
Installing a Hard-Drive Blank |
88 |
Removing a Hard Drive |
88 |
1 If applicable, remove the front bezel. See \ |
88 |
2 Using the RAID management software, prepare the drive for removal. Wait until the hard-drive indicators on the drive carrier signal that the drive can be removed safely. See \ |
88 |
3 Press the release button and open the drive carrier release handle to release the drive. See Figure 3-8. |
88 |
4 Slide the hard drive out of the drive bay. |
88 |
5 Insert a drive blank in the vacated drive bay. See \ |
88 |
Figure 3-8. Removing and Installing a Hard Drive |
89 |
Installing a Hard Drive |
89 |
1 If applicable, remove the front bezel. See \ |
89 |
2 If a drive blank is present in the bay, remove it. See \ |
89 |
3 Press the button on the front of the drive carrier. |
89 |
4 With the lever on the hard drive carrier open, slide the hard drive into the drive bay until the carrier contacts the backplane. See Figure 3-8. |
90 |
5 Close the handle to lock the drive in place. |
90 |
Removing a Hard Drive From a Hard-Drive Carrier |
90 |
Figure 3-9. Installing a Hard Drive Into a Drive Carrier |
90 |
Installing a Hard Drive Into a Hard-Drive Carrier |
91 |
1 Insert the hard drive into the hard-drive carrier with the connector end of the drive at the back. See Figure 3-9. |
91 |
2 Align the holes on the hard drive with the holes on the hard-drive carrier. |
91 |
3 Attach the four screws to secure the hard drive to the hard-drive carrier. |
91 |
Internal Hard Drives |
91 |
Removing an Internal Hard-Drive Bay |
91 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and from the peripherals. |
91 |
2 Open the system. See \ |
91 |
3 Lift the latch on your internal hard drive bay and lift it out of the system. See Figure 3-10. |
91 |
Figure 3-10. Removing and Installing an Internal Hard-Drive Bay |
92 |
Installing an Internal Hard-Drive Bay |
93 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and from the peripherals. |
93 |
2 Open the system. See \ |
93 |
3 Lift the latch on your internal hard-drive bay and align the bay on the support bracket. |
93 |
4 Rotate the latch to lock. |
93 |
Removing an Internal Hard Drive From the Internal Hard-Drive Bay |
93 |
Figure 3-11. Removing and Installing an Internal Hard Drive From the Internal Hard-Drive Bay |
94 |
Installing a Hard Drive Into a Hard-Drive Bay |
94 |
1 Insert the hard drive into the internal hard-drive bay with the connector end of the drive at the back, until it is flush with the back of the hard-drive bay. See Figure 3-11. |
94 |
2 Attach the four screws to secure the hard drive to the hard-drive bracket. |
94 |
Optical Drive (Optional) |
95 |
Removing an Optical Drive |
95 |
1 If applicable, remove the front bezel. See \ |
95 |
2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. |
95 |
3 Open the system. See \ |
95 |
4 Disconnect the optical drive cable from the back of the drive. |
95 |
5 To remove the drive, press down the blue release tab at the back of the optical drive and gently push the drive out of the system. See Figure 3-12. |
95 |
6 If you are not adding a new optical drive, replace the optical drive insert. |
95 |
Figure 3-12. Removing and Installing the Optical Drive |
96 |
Installing an Optical Drive |
96 |
1 If applicable, remove the front bezel. See \ |
96 |
2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. |
96 |
3 Open the system. See \ |
96 |
4 If applicable, remove the optical drive blank by pressing down on the blue release tab at the back of the blank and push the blank out of the system. |
96 |
5 Align the optical drive with its opening in the front panel. See Figure 3-12. |
96 |
6 Slide in the optical drive until the latch snaps into place. |
97 |
7 Connect the optical drive cable to the back of the drive. |
97 |
8 Connect the data cable to the system board and the interface cable to SAS_B on the backplane. See Figure 6-1. |
97 |
9 Close the system. See \ |
97 |
10 If applicable, replace the front bezel. See \ |
97 |
11 Reconnect the system and peripherals to their electrical outlets, and turn on the system. |
97 |
Cooling Fans |
97 |
Removing a Cooling Fan |
98 |
1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. |
98 |
2 Open the system. See \ |
98 |
3 If applicable, remove the cooling shroud. See \ |
98 |
4 Disconnect the fan’s power cable from the system board or power distribution board as applicable. See Figure 3-14. |
98 |
5 Press the release tab while grasping the ends of the fan and lift the fan straight up from the fan bracket. See Figure 3-13 and Figure 3-14. |
98 |
Figure 3-13. Removing and Installing a Fan (Eight-Hard-Drive System) |
99 |
Figure 3-14. Removing and Installing a Fan (Twelve-Hard-Drive System) |
100 |
Installing a Cooling Fan |
101 |
1 Align the fan module so that the side with the power cable faces toward the back of the system. |
101 |
2 Slide the fan module into the fan assembly until the fan is fully seated. See Figure 3-13 and Figure 3-14. |
101 |
3 Connect the fan’s power cable to the power connector on the system board or power distribution board as applicable. |
101 |
4 Route the power cable through the guides on the chassis. |
101 |
5 Replace the cooling shroud. See \ |
101 |
6 Close the system. See \ |
101 |
7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
101 |
Power Supplies |
102 |
Removing a Power Supply |
102 |
1 Disconnect the power cable from the power source. |
102 |
2 Disconnect the power cable from the power supply and remove the system cables from the Velcro straps. |
102 |
3 Press the lever release latch and slide the power supply out of the chassis. See Figure 3-15. |
102 |
Figure 3-15. Removing and Installing a Power Supply |
103 |
Installing a Power Supply |
103 |
1 Verify that both power supplies are of the same type and have the same maximum output power. |
103 |
2 Slide the new power supply into the chassis until the power supply is fully seated and the release latch snaps into place. See Figure 3-15. |
103 |
3 Connect the power cable to the power supply and plug the cable into a power outlet. |
104 |
Removing the Power Supply Blank |
104 |
Installing the Power Supply Blank |
104 |
System Memory |
104 |
General Memory Module Installation Guidelines |
105 |
Mode-Specific Guidelines |
106 |
Optimizer (Independent Channel) Mode |
106 |
Table 3-1. Sample RDIMM Single- and Dual-Rank Memory Configurations (Per Processor) |
107 |
Table 3-2. Sample UDIMM Memory Configurations (Per Processor) |
107 |
Installing Memory Modules |
108 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
108 |
2 Open the system. See \ |
108 |
3 Remove the cooling shroud. See \ |
108 |
4 Locate the memory module sockets. See Figure 6-1. |
108 |
5 Press the ejectors on the memory module socket down and out, as shown in Figure 3-16, to allow the memory module to be inserted into the socket. |
108 |
6 Handle each memory module only on either card edge, making sure not to touch the middle of the memory module. |
108 |
Figure 3-16. Removing and Installing a Memory Module |
109 |
7 Align the memory module's edge connector with the alignment key of the memory module socket, and insert the memory module in the socket. |
109 |
8 Press down on the memory module with your thumbs to lock the memory module into the socket. |
109 |
9 Repeat step 5 through step 8 of this procedure to install the remaining memory modules. See Table 3-2. |
109 |
10 Replace the cooling shroud. See \ |
109 |
11 Close the system. See \ |
109 |
12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
110 |
13 Start up the system, press <F2> to enter the System Setup program, and check the System Memory settings on the main System Setup screen. |
110 |
14 If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 2 through step 13 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets. |
110 |
15 Run the system memory test in the system diagnostics. See \ |
110 |
Removing Memory Modules |
110 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
110 |
2 Open the system. See \ |
110 |
3 Remove the cooling shroud. See \ |
110 |
4 Locate the memory module sockets. See Figure 6-1. |
110 |
5 Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 3-16. |
110 |
6 Replace the cooling shroud. See \ |
111 |
7 Close the system. See \ |
111 |
8 Reconnect the system and peripherals to their power sources, and turn them on. |
111 |
Expansion Cards and Expansion-Card Risers |
111 |
Expansion Card Installation Guidelines |
111 |
Table 3-3. Expansion-Card Installation Priority for Riser 1 |
112 |
Table 3-4. Expansion-Card Installation Priority for Riser 2 |
112 |
Installing an Expansion Card |
113 |
1 Unpack the expansion card and prepare it for installation. |
113 |
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
113 |
3 Open the system. See \ |
113 |
4 Remove the cooling shroud. See \ |
113 |
5 Open the expansion-card latch and remove the filler bracket. See Figure 3-17. |
113 |
6 Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion-card connector on the expansion-card riser. |
113 |
7 Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated. |
113 |
8 Close the expansion-card latch. See Figure 3-17. |
113 |
Figure 3-17. Removing and Installing an Expansion Card |
114 |
9 Connect any cables to the expansion card. |
114 |
10 Close the system. See \ |
114 |
11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
114 |
Removing an Expansion Card |
115 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
115 |
2 Open the system. See \ |
115 |
3 Remove the cooling shroud. See \ |
115 |
4 Disconnect all cables from the card. |
115 |
5 Open the expansion-card latches. See Figure 3-17. |
115 |
6 Grasp the expansion card by its edges, and carefully remove it from the expansion-card connector. |
115 |
7 If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch. |
115 |
8 Close the system. See \ |
115 |
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
115 |
Removing an Expansion-Card Riser |
116 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
116 |
2 Open the system. See \ |
116 |
3 Remove the cooling shroud. See \ |
116 |
4 If installed, remove the expansion card from the expansion-card slot. See \ |
116 |
5 If installed, remove the storage controller card. See \ |
116 |
6 Disconnect the cables connected to the riser card. |
116 |
7 To remove the expansion-card riser, simultaneously press both the blue tabs on the expansion-card riser and lift it from the chassis. See Figure 3-18. |
116 |
Figure 3-18. Removing and Installing an Expansion-Card Riser |
117 |
Installing an Expansion-Card Riser |
118 |
1 To install an expansion-card riser, align the riser guides with the riser guide posts on the system board. See Figure 3-18. |
118 |
2 Lower the expansion-card riser into place until the expansion-card riser connector is fully seated. |
118 |
3 If applicable, reinstall the expansion card. See \ |
118 |
4 Reinstall the storage controller card. See \ |
118 |
5 Reconnect all cables. |
118 |
6 Replace the cooling shroud. See \ |
118 |
7 Close the system. See \ |
118 |
8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
118 |
Integrated Storage Controller Card |
119 |
Removing the Storage Controller Card |
119 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
119 |
2 Open the system. See \ |
119 |
3 If installed, remove the expansion card. See \ |
119 |
4 Disconnect the SAS cables connected to the card. |
119 |
5 Disconnect the cable connecting the card to the expansion-card riser. |
119 |
6 For a battery-cached RAID controller, disconnect the cable connecting the card to the RAID battery. |
119 |
7 Bend both the card-edge guides outward and pull the storage controller card out of the connector. |
119 |
Figure 3-19. Removing and Installing the Storage Controller Card |
120 |
Installing the Storage Controller Card |
121 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
121 |
2 Open the system. See \ |
121 |
3 If installed, remove the expansion card. See \ |
121 |
4 Route the cables in the cable path under the storage controller card slot on the expansion card riser. |
121 |
5 With the storage controller card edge facing the riser, insert one side of the card into the black card-edge guide. |
121 |
6 Bend outward on the blue card-edge guide, lower the card onto the blue card-edge guide, and release the guide. See Figure 3-19. |
121 |
7 Slide the storage controller’s card edge connector into the card slot on the riser until the card is fully seated. |
121 |
8 Connect the two SAS data cable connectors, CNTRL 0 and CNTRL 1, to the storage controller card. See Figure 3-19. |
121 |
9 For a battery-cached RAID controller, connect the RAID battery cable to the controller card. |
121 |
10 Replace the expansion card. See \ |
122 |
11 Close the system. See \ |
122 |
12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
122 |
iDRAC6 Express Card (Optional) |
122 |
Installing an iDRAC6 Express Card |
122 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
122 |
2 Open the system. See \ |
122 |
3 If installed, remove all expansion cards from expansion-card riser. \ |
122 |
4 Insert the notch on the iDRAC6 Express card into the clip on the system board. |
122 |
5 Align the front edge of the card with the connector on the system board. See Figure 6-1 for the location of the connector. |
122 |
6 Press the card down until it is fully seated. See Figure 3-20. |
122 |
Figure 3-20. Removing and Installing an iDRAC6 Express Card |
123 |
7 Reinstall all expansion cards in the expansion-card riser. See \ |
123 |
8 Close the system. See \ |
123 |
9 Reconnect the system and peripherals to their power sources, and turn them on. |
123 |
Removing an iDRAC6 Express Card |
123 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
123 |
2 Open the system. See \ |
123 |
3 Pull back slightly on the retention standoff tab at the front edge of the card and gently lift the card off the retention standoff. See Figure 3-20. |
124 |
4 Angle the card so that the notch on the card slips through the clip on the system board. |
124 |
5 Replace the expansion cards. See \ |
124 |
6 Close the system. See \ |
124 |
7 Reconnect the system and peripherals to their power sources, and turn them on. |
124 |
iDRAC6 Enterprise Card (Optional) |
124 |
Installing an iDRAC6 Enterprise Card |
124 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
124 |
2 Open the system. See \ |
124 |
3 Remove the cooling shroud. See \ |
124 |
4 Remove the plastic filler plug of the iDRAC6 Enterprise port from the system back panel. |
124 |
5 Angle the card so that the RJ-45 connector fits through the back-panel opening. See Figure 3-21. |
124 |
6 Align the front edge of the card with the two front plastic retention standoffs next to the iDRAC6 connector on the system board, and lower the card into place. See Figure 3-21. |
124 |
Figure 3-21. Removing and Installing an iDRAC6 Enterprise Card |
125 |
7 If applicable, install the VFlash media card. See \ |
125 |
8 Close the system. See \ |
125 |
9 Reconnect the system and peripherals to their power sources, and turn them on. |
125 |
Removing an iDRAC6 Enterprise Card |
126 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
126 |
2 If present, disconnect the Ethernet cable from the iDRAC6 enterprise card connector on the system back panel. See Figure 1-5. |
126 |
3 Open the system. See \ |
126 |
4 Remove the cooling shroud. See \ |
126 |
5 Remove the VFlash media card (if installed) from the iDRAC6 enterprise card. See \ |
126 |
6 Pull back slightly on the two tabs at the front edge of the card and gently lift the front edge of the card off of the retention standoffs. |
126 |
7 Slide the card away from the back of the system until the RJ-45 connector is clear of the back panel, then lift the card out of the system. |
126 |
8 Replace the plastic filler plug over the port at the system back panel. See \ |
126 |
9 Replace the cooling shroud. See \ |
126 |
10 Close the system. See \ |
126 |
11 Reconnect the system and peripherals to their power sources, and turn them on. |
126 |
VFlash Media (Optional) |
127 |
Installing a VFlash Media Card |
127 |
1 Locate the VFlash media slot at the back of the system. |
127 |
2 With the label side facing up, insert the contact-pin end of the SD card into the card slot on the module. |
127 |
3 Press inward on the card to lock it into the slot. |
127 |
Removing a VFlash Media Card |
127 |
Internal USB Memory Key |
127 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
127 |
2 Open the system. See \ |
127 |
3 Locate the USB connector on the control panel or SAS backplane, based on your system configuration. See Figure 3-28 or Figure 3-30. |
127 |
4 Insert the USB memory key into the USB connector. See Figure 3-22. |
128 |
5 Close the system. See \ |
128 |
6 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
128 |
7 Enter the System Setup program and verify that the USB key has been detected by the system. See \ |
128 |
Figure 3-22. Removing and Installing a USB Memory Key |
128 |
Processors |
128 |
Removing a Processor |
128 |
1 Prior to upgrading your system, download the latest system BIOS version on support.dell.com. |
128 |
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
128 |
3 Open the system. See \ |
129 |
4 Remove the cooling shroud. See \ |
129 |
5 Using a #2 Phillips screwdriver, loosen one of the heat-sink retention screws. See Figure 3-23. |
129 |
6 Wait 30 seconds for the heat sink to loosen from the processor. |
129 |
7 Loosen the other three heat-sink retention screws. |
129 |
8 Gently lift the heat sink off of the processor and set the heat sink aside with thermal grease side facing up. |
129 |
9 Position your thumb firmly over the processor socket-release lever and release the lever from the locked position. Rotate the lever 90 degrees upward until the processor is released from the socket. See Figure 3-24. |
129 |
Figure 3-23. Removing and Installing the Heat Sink |
130 |
10 Rotate the processor shield upward and out of the way. See Figure 3-24. |
130 |
11 Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor. |
130 |
Figure 3-24. Removing and Installing a Processor |
131 |
Installing a Processor |
132 |
1 If you are upgrading your processors, prior to upgrading your system, download and install the latest system BIOS version from support.dell.com. Follow the instructions included in the file download to install the update on your system. |
132 |
2 Unpack the processor if it has not been used previously. |
132 |
3 Align the processor with the socket keys on the ZIF socket. See Figure 3-24. |
132 |
4 With the release lever on the processor socket in the open position, align the processor with the socket keys and set the processor lightly in the socket. |
132 |
5 Close the processor shield. |
132 |
6 Rotate the socket release lever down until it snaps into place. |
132 |
7 Using a clean lint-free cloth, remove the thermal grease from the heat sink. |
132 |
8 Open the grease packet included with your processor kit and apply thermal grease evenly to the center of the top of the new processor. |
132 |
9 Place the heat sink on the processor. See Figure 3-23. |
132 |
10 Using a #2 Phillips screwdriver, tighten the heat-sink retention screws. See Figure 3-23. |
133 |
11 Replace the cooling shroud. See \ |
133 |
12 Close the system. See \ |
133 |
13 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
133 |
14 Press <F2> to enter the System Setup program, and check that the processor information matches the new system configuration. See \ |
133 |
15 Run the system diagnostics to verify that the new processor operates correctly. |
133 |
System Battery |
133 |
Replacing the System Battery |
133 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
133 |
2 Open the system. See \ |
133 |
3 Remove the cooling shroud. See \ |
133 |
Figure 3-25. Replacing the System Battery |
134 |
4 If installed, remove the expansion card from the expansion-card slot. See \ |
134 |
5 If installed, remove the storage controller card. See \ |
134 |
6 Remove the expansion-card riser. See \ |
134 |
7 Locate the battery socket. See \ |
134 |
8 Support the battery connector by firmly holding the positive side of the connector. |
134 |
9 Press the battery toward the negative side of the connector and lift it out of the securing tab. |
135 |
10 Support the battery connector by pressing down firmly on the positive side of the connector. |
135 |
11 Hold the new battery with the \ |
135 |
12 Press the battery straight down into the connector until it snaps into place. |
135 |
13 Replace the expansion-card riser. See \ |
135 |
14 Replace the storage controller card. See \ |
135 |
15 Replace the expansion card from the expansion-card slot. See \ |
135 |
16 Replace the cooling shroud. See \ |
135 |
17 Close the system. See \ |
135 |
18 Reconnect the system to the electrical outlet and turn the system on, including any attached peripherals. |
135 |
19 Enter the System Setup program to confirm that the battery is operating properly. See \ |
135 |
20 Enter the correct time and date in the System Setup program's Time and Date fields. |
135 |
21 Exit the System Setup program. |
135 |
RAID Battery (Optional) |
136 |
Removing the RAID Battery |
136 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
136 |
2 Open the system. See \ |
136 |
3 Disconnect the RAID battery cable by gently pulling the cable connector out of the connector. See Figure 3-26. |
136 |
4 Pull back gently on the two tabs holding the RAID battery and lift the RAID battery from the battery carrier. See Figure 3-26. |
136 |
Figure 3-26. Removing and Installing the RAID Battery |
136 |
Installing the RAID Battery |
137 |
1 Insert the RAID battery into the battery carrier until it locks into place. See Figure 3-26. |
137 |
2 Connect the cable to the battery. See Figure 3-26. |
137 |
3 Close the system. See \ |
137 |
4 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
137 |
Control Panel Assembly-LED |
137 |
Removing the Control-Panel Module-LED |
137 |
1 If applicable, remove the front bezel. See \ |
137 |
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. |
137 |
3 Remove the single screw securing the bracket to the module and remove the bracket. |
137 |
4 Disconnect the control-panel cable at back of the module by using the pull tab. See Figure 3-27. |
137 |
5 Remove the screw securing the power button board to the control-panel module. See Figure 3-27. |
138 |
6 Remove the power button board and power button from the control-panel module. |
138 |
Figure 3-27. Removing and Installing the Control Panel-LED |
138 |
Installing the Control-Panel Module-LED |
139 |
1 Assemble the power button and power button board in the control-panel module. |
139 |
2 Tighten the screw to secure the power button board to the control-panel module. See Figure 3-27. |
139 |
3 Connect the control-panel cable to the control-panel module. |
139 |
4 Replace the bracket and tighten the single screw to secure the bracket to the back of the control-panel module. |
139 |
5 Reconnect the system to the power source and turn on the system and attached peripherals. |
139 |
6 If applicable, replace the front bezel. See \ |
139 |
Control Panel Assembly-LCD (Optional) |
140 |
Removing the Control Panel Display Module |
140 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. |
140 |
2 If applicable, remove the front bezel. See \ |
140 |
3 Open the system. See \ |
140 |
4 Disconnect the display module cable from the control panel board. See Figure 3-28. |
140 |
5 Using a knife or a small flat-blade screwdriver, insert the blade beneath the front panel of the display and slide the blade across the bottom to lift the panel outward. See Figure 3-28. |
140 |
6 Remove the front panel plate until it separates from the display module to allow access to the mounting screws. |
140 |
7 Remove the two screws that secure the display module to the system chassis. |
140 |
8 Remove the display module from the chassis cutout. |
140 |
Installing the Control Panel Display Module |
141 |
1 Insert the display module into the chassis cutout and secure it with the Torx screw. See Figure 3-28. |
141 |
2 Attach the replacement panel to the front of the display module. |
141 |
3 Connect the display module cable to the control panel board. |
141 |
4 Close the system. See \ |
141 |
5 Reconnect the system to the power source and turn on the system and attached peripherals. |
141 |
6 If applicable, install the front bezel. See \ |
141 |
Removing the Control Panel Assembly |
141 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. |
141 |
2 Open the system. See \ |
141 |
3 Disconnect the control panel cable at the back of the control panel board by pressing the metal tabs on the ends of the cable connector and gently working the connector out of the socket. |
141 |
4 Disconnect the USB cable at the back of the control panel board. See Figure 3-28. |
141 |
5 Disconnect the display module cable from the control panel board. See Figure 3-28. |
142 |
6 Remove the two screws that secure the control panel board to the system chassis and remove the board. |
142 |
Figure 3-28. Removing and Installing the Control Panel-LCD |
142 |
Installing the Control Panel Assembly |
143 |
1 Install the control panel board in the system chassis and secure it with the two screws. See Figure 3-28. |
143 |
2 Connect the display module cable to the control panel board. See Figure 3-28. |
143 |
3 Connect the control panel cable to the control panel board. See Figure 3-28. |
143 |
4 Connect the USB cable to the control panel board. See Figure 3-28. |
143 |
5 Close the system. See \ |
143 |
6 Reconnect the system to the power source and turn on the system and attached peripherals. |
143 |
SAS Backplane |
143 |
Removing the SAS Backplane |
143 |
1 If applicable, remove the front bezel. See \ |
143 |
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
143 |
3 Open the system. See \ |
144 |
4 Remove all hard drives. See \ |
144 |
5 Disconnect the power cable from the end of the SAS backplane. |
144 |
6 Disconnect the SAS data cables from the backplane. |
144 |
7 Disconnect the optical-drive cable, USB cable, and the control-panel cable. |
144 |
8 While pressing the two blue latches toward each other, lift the backplane upward. See Figure 3-30. |
144 |
9 When the backplane cannot slide upward any farther, pull the backplane toward the back of the system to remove it from the retention hooks. |
144 |
10 Lift the board out of the system, being careful to avoid damaging components on the face of the board. |
144 |
11 Place the SAS backplane face down on a work surface. |
144 |
Figure 3-29. Removing and Installing a SAS Backplane (Eight-Hard-Drive System) |
145 |
Figure 3-30. Removing and Installing a SAS Backplane (Twelve-Hard-Drive System) |
146 |
Installing the SAS Backplane |
147 |
1 Lower the backplane into the system, being careful to avoid damaging components on the face of the board. |
147 |
2 Align the slots in the backplane with the retention hooks on the back of the drive bays, then move the backplane forward until the retention hooks fit through the slots in the backplane. See Figure 3-30. |
147 |
3 Slide the backplane downward until the two blue retention latches snap into place. |
147 |
4 Connect the SAS data and power cables to the SAS backplane. |
147 |
5 Install the hard drives in their original locations. |
147 |
6 Connect the optical drive cable, USB cable, and the control panel cable to the system board. |
147 |
7 Close the system. See \ |
147 |
8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
147 |
9 If applicable, install the front bezel. See \ |
147 |
Power Distribution Board |
148 |
Removing the Power Distribution Board |
148 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
148 |
2 Open the system. See \ |
148 |
3 If applicable, remove the internal hard drive bay and support carrier. See \ |
148 |
4 If applicable, remove the thumb screw on the support bracket and lift it up and out of the system. |
148 |
5 Remove the power supplies from the system. See \ |
148 |
6 Remove the expansion cards. See \ |
148 |
7 Remove the expansion card riser. See \ |
148 |
8 Disconnect power distribution cables from the system board (see \ |
148 |
9 Disconnect the fan cable. |
148 |
10 Remove the screws securing the power distribution board to the chassis. See Figure 3-31 and Figure 3-32. |
148 |
11 Pull the blue tab, lift the power distribution board, and move it toward the front of the system to disengage from the tabs on the power supply bay. See Figure 3-31 and Figure 3-32. |
149 |
Figure 3-31. Removing and Installing the Power Distribution Board (Eight-Hard-Drive System) |
149 |
Figure 3-32. Removing and Installing the Power Distribution Board (Twelve-Hard- Drive System) |
150 |
Replacing the Power Distribution Board |
151 |
1 Unpack the new power distribution board assembly. |
151 |
2 Align the power distribution board with the tabs on the chassis and slide it in place until the blue tab snaps over the edge of the board. See Figure 3-32. |
151 |
3 Install the four screws that secure the power distribution board to the chassis. See Figure 3-31 and Figure 3-32. |
151 |
4 Connect the power distribution cables to the system board (see \ |
151 |
5 If applicable, align the support bracket over the power distribution board and secure in place with the screw. |
151 |
6 If applicable, install the internal hard-drive bay. See \ |
151 |
7 Install the power supplies in the system. See \ |
151 |
8 Replace the expansion-card riser. See \ |
151 |
9 Replace the expansion cards. See \ |
151 |
10 Close the system. See \ |
151 |
11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
151 |
System Board |
152 |
Removing the System Board |
152 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
152 |
2 Open the system. See \ |
152 |
3 Remove the cooling shroud. See \ |
152 |
4 Remove the power supplies. See \ |
152 |
5 Remove all expansion cards and, if applicable, the storage controller card. See \ |
152 |
6 Remove the expansion-card riser. See \ |
152 |
7 Remove the heat sinks, processors, and heat-sink blanks. See \ |
152 |
8 If installed, remove the iDRAC6 Enterprise card. See \ |
152 |
9 If installed, remove the iDRAC6 Express card. See \ |
152 |
10 Disconnect all cables from the system board. |
152 |
11 Remove the nine screws securing the system board to the chassis and then slide the system board assembly toward the front end of the chassis. |
153 |
12 Grasp the system board assembly by the edges and lift the system board assembly away from the chassis. See Figure 3-33. |
153 |
Figure 3-33. Removing and Installing the System Board |
153 |
Installing the System Board |
154 |
1 Unpack the new system board. |
154 |
2 Remove the labels from the processor shield and affix them to the system identification panel on the front of the system. See Figure 1-1. |
154 |
3 Holding the system board by the edges, lower it into the chassis. |
154 |
4 Slightly lift up the front of the system board and maneuver the system board to the bottom of the chassis until it lays completely flat. |
154 |
5 Push the system board toward the back of the chassis until the board is in place. |
154 |
6 Tighten the nine screws that secure the system board to the chassis. See Figure 3-33. |
154 |
7 Transfer the processors to the new system board. See \ |
154 |
8 Remove the memory modules and transfer them to the same locations on the new board. See \ |
154 |
9 Connect the cables to the system board. See Figure 6-1 for the locations of the connectors on the system board. |
154 |
10 Replace the expansion-card riser. See \ |
154 |
11 Install all expansion cards. See \ |
154 |
12 If applicable, reinstall the storage controller card. See \ |
154 |
13 If applicable, install the iDRAC6 Enterprise card. See \ |
155 |
14 If applicable, install the iDRAC6 Express card. See \ |
155 |
15 Replace the cooling shroud. See \ |
155 |
16 Close the system. See \ |
155 |
17 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. |
155 |
4 |
157 |
Troubleshooting Your System |
157 |
Safety First-For You and Your System |
157 |
Troubleshooting System Startup Failure |
157 |
Troubleshooting External Connections |
157 |
Troubleshooting the Video Subsystem |
158 |
1 Check the system and power connections to the monitor. |
158 |
2 Check the video interface cabling from the system to the monitor. |
158 |
3 Run the appropriate online diagnostic test. See \ |
158 |
Troubleshooting a USB Device |
158 |
1 Disconnect the keyboard and mouse cables from the system briefly and reconnect them. |
158 |
2 Connect the keyboard/mouse to the USB port(s) on the opposite side of the system. |
158 |
3 If the problem is resolved, restart the system, enter the System Setup program, and check if the nonfunctioning USB ports are enabled. |
158 |
4 Replace the keyboard/mouse with another working keyboard/mouse. |
158 |
5 Power down all attached USB devices and disconnect them from the system. |
158 |
6 Restart the system and, if your keyboard is functioning, enter the system setup program. Verify that all USB ports are enabled. See \ |
158 |
7 Reconnect and power on each USB device one at a time. |
159 |
8 If a device causes the same problem, power down the device, replace the USB cable, and power up the device. |
159 |
Troubleshooting a Serial I/O Device |
159 |
1 Turn off the system and any peripheral devices connected to the serial port. |
159 |
2 Swap the serial interface cable with another working cable, and turn on the system and the serial device. |
159 |
3 Turn off the system and the serial device, and swap the device with a comparable device. |
159 |
4 Turn on the system and the serial device. |
159 |
Troubleshooting a NIC |
159 |
1 Run the appropriate online diagnostic test. See \ |
159 |
2 Restart the system and check for any system messages pertaining to the NIC controller. |
159 |
3 Check the appropriate indicator on the NIC connector. See \ |
159 |
4 Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation. |
160 |
5 Enter the System Setup program and confirm that the NIC ports are enabled. See \ |
160 |
6 Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the documentation for each network device. |
160 |
7 Ensure that all network cables are of the proper type and do not exceed the maximum length. |
160 |
Troubleshooting a Wet System |
160 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
160 |
2 Open the system. See \ |
160 |
3 Disassemble components from the system. See \ |
160 |
4 Let the system dry thoroughly for at least 24 hours. |
161 |
5 Reinstall the components you removed in step 3. |
161 |
6 Close the system. See \ |
161 |
7 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
161 |
8 If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See \ |
161 |
9 Run the appropriate online diagnostic test. See \ |
161 |
Troubleshooting a Damaged System |
162 |
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
162 |
2 Open the system. See \ |
162 |
3 Ensure that the following components are properly installed: |
162 |
4 Ensure that all cables are properly connected. |
162 |
5 Close the system. See \ |
162 |
6 Run the system board tests in the system diagnostics. See \ |
162 |
Troubleshooting the System Battery |
162 |
1 Re-enter the time and date through the System Setup program. See \ |
162 |
2 Turn off the system and disconnect it from the electrical outlet for at least one hour. |
162 |
3 Reconnect the system to the electrical outlet and turn on the system. |
163 |
4 Enter the System Setup program. |
163 |
Troubleshooting Power Supplies |
163 |
1 Identify the faulty power supply by the power supply's fault indicator. See \ |
163 |
2 Reseat the power supply by removing and reinstalling it. See \ |
163 |
3 If all troubleshooting fails, see \ |
163 |
Troubleshooting System Cooling Problems |
163 |
Troubleshooting a Fan |
164 |
1 Locate the faulty fan indicated by the LCD panel or the diagnostic software. |
164 |
2 Turn off the system and all attached peripherals. |
164 |
3 Open the system. See \ |
164 |
4 Reseat the fan's power cable. |
164 |
5 Restart the system. |
164 |
6 If the fan does not function, turn off the system and install a new fan. See \ |
164 |
7 Restart the system. |
164 |
Troubleshooting System Memory |
165 |
1 If the system is operational, run the appropriate online diagnostic test. See \ |
165 |
2 If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least 10 seconds and then reconnect the system to power. |
165 |
3 Turn on the system and attached peripherals and note the messages on the screen. |
165 |
4 Enter the System Setup program and check the system memory setting. See \ |
165 |
5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
165 |
6 Open the system. See \ |
165 |
7 Remove the cooling shroud. See \ |
165 |
8 Check the memory channels and ensure that they are populated correctly. See \ |
165 |
9 Reseat the memory modules in their sockets. See \ |
166 |
10 Replace the cooling shroud. See \ |
166 |
11 Close the system. See \ |
166 |
12 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. |
166 |
13 Enter the System Setup program and check the system memory setting. See \ |
166 |
14 Turn off the system and attached peripherals, and disconnect the system from the power source. |
166 |
15 Open the system. See \ |
166 |
16 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module. |
166 |
17 To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a module of the same type and capacity. See \ |
166 |
18 Close the system. See \ |
166 |
19 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. |
166 |
20 As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system. |
166 |
21 If the memory problem is still indicated, repeat step 14 through step 20 for each memory module installed. |
166 |
Troubleshooting an Internal USB Key |
167 |
1 Enter the System Setup program and ensure that the USB key port is enabled. See \ |
167 |
2 Turn off the system and attached peripherals. |
167 |
3 Open the system. See \ |
167 |
4 Locate the USB key and reseat it. See \ |
167 |
5 Close the system. See \ |
167 |
6 Turn on the system and attached peripherals and check if the USB key is functioning. |
167 |
7 If the problem is not resolved, repeat step 2 and step 3. |
167 |
8 Insert a different USB key that you know works properly. |
167 |
9 Close the system. See \ |
167 |
10 Turn on the system and attached peripherals and check if the USB key is functioning. |
167 |
11 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
167 |
Troubleshooting an Optical Drive |
168 |
1 If applicable, remove the front bezel. See \ |
168 |
2 Try using a different CD or DVD. |
168 |
3 Enter the System Setup program and ensure that the integrated SATA controller and the drive's SATA port are enabled. See \ |
168 |
4 Run the appropriate online diagnostic test. See \ |
168 |
5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
168 |
6 Open the system. See \ |
168 |
7 Ensure that the interface cable is securely connected to the optical drive and to the system board. |
168 |
8 Ensure that a power cable is properly connected to the drive. |
168 |
9 Close the system. See \ |
168 |
10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
168 |
Troubleshooting a Hard Drive |
169 |
1 Run the appropriate online diagnostics test. See \ |
169 |
2 If applicable, remove the front bezel. See \ |
169 |
3 If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps: |
169 |
a Restart the system and enter the host adapter configuration utility program by pressing <Ctrl><R> for a PERC controller or <Ctrl><C> for a SAS controller. |
169 |
b Ensure that the hard drive(s) have been configured correctly for the RAID array. |
169 |
c Take the hard drive offline and reseat the drive. See \ |
169 |
d Exit the configuration utility and allow the system to boot to the operating system. |
169 |
4 Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information. |
169 |
5 Restart the system, enter the System Setup program, and verify that the controller is enabled and the drives appear in the System Setup program. See \ |
170 |
6 Replace the front bezel. See \ |
170 |
Troubleshooting an Internal Hard Drive |
170 |
1 Run the appropriate online diagnostics test. See \ |
170 |
2 If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps: |
170 |
a Restart the system and enter the host adapter configuration utility program by pressing <Ctrl><R> for a PERC controller or <Ctrl><C> for a SAS controller. |
170 |
b Ensure that the hard drive(s) have been configured correctly for the RAID array. |
170 |
c Take the hard drive offline and reseat the drive. See \ |
170 |
d Exit the configuration utility and allow the system to boot to the operating system. |
170 |
3 Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information. |
171 |
4 Restart the system, enter the System Setup program, and verify that the controller is enabled and the drives appear in the System Setup program. See \ |
171 |
Troubleshooting a Storage Controller |
171 |
1 Run the appropriate online diagnostic test. See \ |
171 |
2 Enter the System Setup program and ensure that the SAS or PERC controller is enabled. See \ |
171 |
3 Restart the system and press the applicable key sequence to enter the configuration utility program. |
171 |
4 Check the configuration settings, make any necessary corrections, and restart the system. |
171 |
5 If applicable, remove the front bezel. See \ |
171 |
6 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet. |
171 |
7 Open the system. See \ |
172 |
8 Ensure that the controller card is firmly seated into the system board connector. See \ |
172 |
9 If you have a battery-cached PERC controller, ensure that the RAID battery is properly connected and, if applicable, the memory module on the PERC card is properly seated. |
172 |
10 Verify that the cable connections between the SAS backplane(s) and the integrated storage controller are correct. See \ |
172 |
11 Close the system. See \ |
172 |
12 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. |
172 |
13 If applicable, replace the front bezel. See \ |
172 |
Troubleshooting Expansion Cards |
172 |
1 Run the appropriate online diagnostic test. See \ |
172 |
2 If applicable, remove the front bezel. See \ |
172 |
3 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
172 |
4 Open the system. See \ |
173 |
5 Ensure that each expansion card is firmly seated in its connector. See \ |
173 |
6 Ensure that each expansion-card riser is firmly seated in its connector. See \ |
173 |
7 Close the system. See \ |
173 |
8 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
173 |
9 If problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
173 |
10 Open the system. See \ |
173 |
11 Remove all expansion cards installed in the system. See \ |
173 |
12 Close the system. See \ |
173 |
13 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
173 |
14 Run the appropriate online diagnostic test. See \ |
173 |
15 For each expansion card you removed in step 11, perform the following steps: |
173 |
a Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
173 |
b Open the system. See \ |
173 |
c Reinstall one of the expansion cards. |
173 |
d Close the system. See \ |
173 |
e Run the appropriate diagnostic test. |
173 |
Troubleshooting Processors |
174 |
1 Run the appropriate online diagnostics test. See \ |
174 |
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
174 |
3 Open the system. See \ |
174 |
4 Ensure that each processor and heat sink are properly installed. See \ |
174 |
5 Close the system. See \ |
174 |
6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
174 |
7 Run the appropriate online diagnostic test. See \ |
174 |
8 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
174 |
9 Open the system. See \ |
174 |
10 Remove processor 2. See \ |
174 |
11 Close the system. See \ |
174 |
12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. |
174 |
13 Run the appropriate online diagnostic test. See \ |
174 |
14 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. |
174 |
15 Open the system. See \ |
174 |
16 Replace processor 1 with processor 2. See \ |
175 |
17 Repeat step 11 through step 13. |
175 |
5 |
177 |
Running the System Diagnostics |
177 |
Using Online Diagnostics |
177 |
Embedded System Diagnostics Features |
177 |
When to Use the Embedded System Diagnostics |
178 |
Running the Embedded System Diagnostics |
178 |
1 As the system boots, press <F10> to start the controller. |
178 |
2 Click Diagnostics in the left pane and click Launch Diagnostics in the right pane. |
178 |
Embedded System Diagnostics Testing Options |
179 |
Using the Custom Test Options |
179 |
Selecting Devices for Testing |
179 |
Selecting Diagnostics Options |
179 |
Viewing Information and Results |
180 |
6 |
181 |
Jumpers and Connectors |
181 |
System Board Jumpers |
181 |
Table 6-1. System Board Jumper Settings |
181 |
System Board Connectors |
182 |
Figure 6-1. System Board Connectors |
182 |
Table 6-2. System Board Connectors |
183 |
Disabling a Forgotten Password |
184 |
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
184 |
2 Open the system. See \ |
184 |
3 Move the password jumper to the \ |
184 |
4 Close the system. See \ |
184 |
5 Reconnect your system and peripherals to their electrical outlets, and turn on the system. |
185 |
6 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. |
185 |
7 Open the system. See \ |
185 |
8 Move the password jumper back to the enabled position to restore the password function. See Table 6-1. |
185 |
9 Close the system. See \ |
185 |
10 Reconnect your system and peripherals to their electrical outlets, and turn on the system. |
185 |
11 Assign a new system and/or setup password. |
185 |
7 |
187 |
Getting Help |
187 |
Contacting Dell |
187 |
1 Visit support.dell.com. |
187 |
2 Verify your country or region in the Choose A Country/Region drop-down menu at the bottom of the page. |
187 |
3 Click Contact Us on the left side of the page. |
187 |
4 Select the appropriate service or support link based on your need. |
187 |
5 Choose the method of contacting Dell that is convenient for you. |