Dell PowerEdge R720xd Intel 320 Series SSD User's Information for Dell PowerEd - Page 7
Controller BIOS Configuration Utility Behavior, OMSA Drive Information - removable storage
View all Dell PowerEdge R720xd manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
SSD Drive Status Indicator Pattern (RAID Only) Condition NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time. Blinks green and off Blinks green slowly Steady green Blinks green three seconds and off six seconds Predicted drive failure Drive rebuilding Drive online Rebuild aborted Controller BIOS Configuration Utility Behavior The BIOS Configuration Utility is a storage management application embedded on PowerEdge Raid Controller (PERC) cards that configures and maintains RAID disk groups and virtual disks. (For more information on the utility, see the Dell PowerEdge RAID Controller User's Guide.) The utility's Physical Disk Management screen displays physical disk information and action menus. On the right side of the screen, the SSD's Certified field will be set to "No." This is normal behavior and does not indicate an issue with the drive. Figure 2. Controller BIOS configuration utility OMSA Drive Information Page SMART Predictive Failure Notification Support SMART trips for actual drive errors will be noted on the Physical Disks page of the OpenManage Server Administrator (OMSA) Storage subsection. If such an error occurs, "Yes" will be displayed in the Failure Predicted column of this page. 7