9. Is there data integrity risk during sudden power off? If volatile write cache is disabled: • 512n and 4kn HDD, there is no data loss during sudden power off. • Enterprise 512e HDD with NVC and/or MBC/MC feature (see section 5) also does not have data integrity risk. • For 512e without NVC or MBC/MC (Client grade HDD), there is a risk of data integrity during sudden power loss. If volatile write cache is enabled, then sudden power loss will result in data cache loss regardless of the HDD format types. 6 4K Sector HDD FAQ | Dell Inc., 2014

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

6
4K Sector HDD FAQ | Dell Inc., 2014
9.
Is there data integrity risk during sudden power off?
If volatile write cache is disabled:
512n and 4kn HDD, there is no data loss during sudden power off.
Enterprise 512e HDD with NVC and/or MBC/MC feature (see section 5) also does not have
data integrity risk.
For 512e without NVC or MBC/MC (Client grade HDD), there is a risk of data integrity
during sudden power loss.
If volatile write cache is enabled, then sudden power loss will result in data cache loss regardless