Dell PowerEdge R940 EMC Boot Optimized Server Storage-S1 Users Guide - Page 26

Troubleshooting, Importing BOSS ESXi CLI offline bundle may fail in VSphere Lifecycle manager

Page 26 highlights

7 Troubleshooting To get help with your Dell BOSS-S1 card, you can contact your Dell Technical Service representative or see www.dell.com/support. Topics: • Importing BOSS ESXi CLI offline bundle may fail in VSphere Lifecycle manager • BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 • M.2 drive firmware update from iDRAC fails on unconfigured drives with an existing adapter key on the BOSS-S1 controller • Unconfigured drives in BOSS-S1 controller is unavailable for OS installation with an existing adapter key • ROM version for BOSS reported as firmware version in iDRAC interface • Firmware update of M.2 drive on BOSS-S1 controller fails • BOSS-S1 CLI displays No Adapter Found error in Linux • LC log displays fan unavailability error • Updating BOSS-S1 controller firmware using iDRAC or LC fails • Physical disk size not updated in iDRAC • Physical disk/Virtual disk missing in iDRAC • Back Ground Activity task progress in HII does not report real-time status • Virtual disk state will be generated twice • Character limitation while naming a virtual disk • VMFS datastore is disabled on the 14th generation of PowerEdge systems that are shipped with VMware ESXi installed on BOSS-S1 • Physical disk not visible to operating system • Virtual disk not visible to operating system • Drive replacement • Controller replacement • Controller failure • Unable to boot to M.2 drive installed in slot 1 • CLI reports unsupported features • Failure to install ESXi on RAID 1 • System not responding • Management port not responding Importing BOSS ESXi CLI offline bundle may fail in VSphere Lifecycle manager Issue: Importing BOSS ESXi CLI offline bundle into vSphere Lifecycle Manager fails through the vSphere Web Client. For more information, see https://kb.vmware.com/s/article/78688. Corrective Action: This issue is resolved. Deployments and upgrades of vCenter Server 7.0 conducted after April 18, 2020 are not impacted by this issue. For more information, see https://kb.vmware.com/s/article/2147284. BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 Issue: When upgrading from vSphere versions of 6.7.x to version 7.0, sas-raid_boss-cli package update fails. Corrective Action: Remove the driver packages before attempting an upgrade using the command esxcli software vib remove -n . 26 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Troubleshooting
To get help with your Dell BOSS-S1 card, you can contact your Dell Technical Service representative or see
www.dell.com/support
.
Topics:
Importing BOSS ESXi CLI offline bundle may fail in VSphere Lifecycle manager
BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0
M.2 drive firmware update from iDRAC fails on unconfigured drives with an existing adapter key on the BOSS-S1 controller
Unconfigured drives in BOSS-S1 controller is unavailable for OS installation with an existing adapter key
ROM version for BOSS reported as firmware version in iDRAC interface
Firmware update of M.2 drive on BOSS-S1 controller fails
BOSS-S1 CLI displays No Adapter Found error in Linux
LC log displays fan unavailability error
Updating BOSS-S1 controller firmware using iDRAC or LC fails
Physical disk size not updated in iDRAC
Physical disk/Virtual disk missing in iDRAC
Back Ground Activity task progress in HII does not report real-time status
Virtual disk state will be generated twice
Character limitation while naming a virtual disk
VMFS datastore is disabled on the 14th generation of PowerEdge systems that are shipped with VMware ESXi installed on BOSS-S1
Physical disk not visible to operating system
Virtual disk not visible to operating system
Drive replacement
Controller replacement
Controller failure
Unable to boot to M.2 drive installed in slot 1
CLI reports unsupported features
Failure to install ESXi on RAID 1
System not responding
Management port not responding
Importing BOSS ESXi CLI offline bundle may fail in
VSphere Lifecycle manager
Issue:
Importing BOSS ESXi CLI offline bundle into vSphere Lifecycle Manager fails through the vSphere Web Client. For
more information, see
.
Corrective Action:
This issue is resolved. Deployments and upgrades of vCenter Server 7.0 conducted after April 18, 2020 are not
impacted by this issue. For more information, see
.
BOSS ESXi CLI package fails when upgrading from
Dell EMC customized versions of 6.7.x to version
7.0
Issue:
When upgrading from vSphere versions of 6.7.x to version 7.0,
sas-raid_boss-cli
package update fails.
Corrective Action:
Remove the driver packages before attempting an upgrade using the command
esxcli software vib
remove -n <vib name>
.
7
26
Troubleshooting