Dell PowerEdge R940 385TB Data Warehouse Fast Track Reference Architecture for - Page 16

Dwft-4s - Sqllog

Page 16 highlights

Storage configuration volume assigned to each controller. If the volumes are created and mapped to the server, one right after the other, the array should automatically distribute the volumes evenly across the controllers. Otherwise, the controller can be manually selected using the advanced options when mapping the volume to the server. To achieve optimal results, the SQL Server data and tempdb volumes must be evenly distributed across the controllers. SC Series volumes created for the reference architecture Volume name Storage profile Volume purpose DWFT-4S - MPHost Recommended (All Tiers) Mount point host DWFT-4S - SQLSystem Recommended (All Tiers) SQL Server system databases and files DWFT-4S - SQLLog Recommended (All Tiers) Transaction log files for tempdb and the data warehouse DWFT-4S - SQLData01 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData02 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData03 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData04 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData05 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData06 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData07 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLData08 RAID 5 All Tiers Data files for the data warehouse DWFT-4S - SQLTempdb01 Recommended (All Tiers) Data files for tempdb DWFT-4S - SQLTempdb02 Recommended (All Tiers) Data files for tempdb 16 385TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000 | 4032-RA-SQL

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Storage configuration
16
385TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC
PowerEdge R940 and SC9000 | 4032-RA-SQL
volume assigned to each controller. If the volumes are created and mapped to the server, one right after the
other, the array should automatically distribute the volumes evenly across the controllers. Otherwise, the
controller can be manually selected using the advanced options when mapping the volume to the server. To
achieve optimal results, the SQL Server data and tempdb volumes must be evenly distributed across the
controllers.
SC Series volumes created for the reference architecture
Volume name
Storage profile
Volume purpose
DWFT-4S - MPHost
Recommended (All Tiers)
Mount point host
DWFT-4S - SQLSystem
Recommended (All Tiers)
SQL Server system databases and files
DWFT-4S - SQLLog
Recommended (All Tiers)
Transaction log files for tempdb and the
data warehouse
DWFT-4S - SQLData01
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData02
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData03
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData04
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData05
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData06
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData07
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLData08
RAID 5 All Tiers
Data files for the data warehouse
DWFT-4S - SQLTempdb01
Recommended (All Tiers)
Data files for tempdb
DWFT-4S - SQLTempdb02
Recommended (All Tiers)
Data files for tempdb