Dell™ PowerEdge™ SC 1430 Systems Information Update Installing a Fourth Hard Drive A fourth hard drive requires an optional hard-drive carrier with a cooling fan. Installation steps are described in "Installing an Optional Fourth Hard Drive" in your Hardware Owner's Manual. When performing this procedure, note the following additional information: NOTE: If a second processor is installed in your system, do not route the fan cable through the narrow space between the air baffle and the processor heat sink. Open the processor access door on the air baffle and push the fan cable underneath the heat sink fins to prevent damage to the cable. System Messages Table 1 provides an additional system message that your system may display on the screen. See "System Messages" in your Hardware Owner's Manual for information about other system messages. Table 1. System Messages Message The FBD link to the following DIMM failed to train: DIMM x Causes Faulty or improperly installed memory module. Corrective Actions Ensure that only Dell-qualified memory is used. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility. Reseat memory modules. See "Memory" in your Hardware Owner's Manual. If the problem persists, see "Troubleshooting System Memory" in your Hardware Owner's Manual. October 2006

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

Dell™ PowerEdge™
SC
1430 Systems
Information Update
Installing a Fourth Hard Drive
A fourth hard drive requires an optional hard-drive carrier with a cooling fan. Installation steps are
described in "Installing an Optional Fourth Hard Drive" in your
Hardware Owner’s Manual
. When
performing this procedure, note the following additional information:
NOTE:
If a second processor is installed in your system, do not route the fan cable through the narrow space
between the air baffle and the processor heat sink. Open the processor access door on the air baffle and push
the fan cable underneath the heat sink fins to prevent damage to the cable.
System Messages
Table 1 provides an additional system message that your system may display on the screen.
See "System Messages" in your
Hardware Owner’s Manual
for information about
other system messages.
Table 1.
System Messages
Message
Causes
Corrective Actions
The FBD link to the
following DIMM failed
to train: DIMM x
Faulty or improperly installed
memory module.
Ensure that only Dell-qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com
or your Dell sales agent
to ensure compatibility.
Reseat memory modules. See "Memory"
in your
Hardware Owner’s Manual
.
If the problem persists, see
"Troubleshooting System Memory"
in your
Hardware Owner’s Manual
.
October 2006