Dell PowerVault MD3000i Getting Started Guide - Page 14

Power Supplies, Available Physical Disk Power Per Slot, Physical, Environmental Enclosure - storage

Page 14 highlights

Power Supplies Wattage Voltage Frequency Amperage 488 W maximum continuous; 550 W peak 100-240 V rated (actual 90-264 V) 47-63 Hz 7.2 A at 100 V, 3.6 A at 200 V Available Physical Disk Power (Per Slot) Supported physical-disk power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height Width Depth Weight (maximum configuration) 13.11 cm (5.16 in) 44.63 cm (17.57 in) 48.01 cm (18.9 in) 35.37 kg (78 lb) Environmental (Enclosure) NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets Temperature Operating 10° to 35°C (50° to 95°F) Storage -40° to 65°C (-40° to 149°F) Relative humidity Operating 5% to 80% (noncondensing) Storage 5% to 95% (noncondensing) Altitude Operating -16 to 3048 m (-50 to 10,000 ft) Storage -16 to 10,600 m (-50 to 35,000 ft) BTU per hour 1430 (maximum) 12 Getting Started With Your System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

12
Getting Started With Your System
Power Supplies
Wattage
488 W maximum continuous; 550 W
peak
Voltage
100–240 V rated (actual 90–264 V)
Frequency
47–63 Hz
Amperage
7.2 A at 100 V, 3.6 A at 200 V
Available Physical Disk Power (Per Slot)
Supported physical-disk power
consumption
up to 1.3 A at +12 V
up to 1.5 A at +5 V
Physical
Height
13.11 cm (5.16 in)
Width
44.63 cm (17.57 in)
Depth
48.01 cm (18.9 in)
Weight (maximum configuration)
35.37 kg (78 lb)
Environmental (Enclosure)
NOTE:
For additional information about environmental measurements for specific
system configurations, see
dell.com/environmental_datasheets
Temperature
Operating
10° to 35°C (50° to 95°F)
Storage
–40° to 65°C (–40° to 149°F)
Relative humidity
Operating
5% to 80% (noncondensing)
Storage
5% to 95% (noncondensing)
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
Storage
–16 to 10,600 m (–50 to 35,000 ft)
BTU per hour
1430 (maximum)