Dell PowerVault MD3000i Information Update - Page 6
Initiator Configuration
View all Dell PowerVault MD3000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Figure 1. Initiator Configuration host iSCSI initiator network interfaces if1 if2 IP Addresses Host If1: IP_Addr_If1 If2: IP_Addr_If2 MD3000i Controller 0 P0: IP_Addr_C0_P0 P1: IP_Addr_C0_P1 IP Network 1 IP Network 2 MD3000i Controller 1 P0: IP_Addr_C1_P0 P1: IP_Addr_C1_P1 TCP Connections To MD3000i Controller 0 T01: IP_Addr_If1 / IP_Addr_C0_P0 T02: IP_Addr_If2 / IP_Addr_C1_P1 P0 P1 controller 0 P0 P1 controller 1 To MD3000i Controller 1 T11: IP_Addr_If1 / IP_Addr_C1_P0 T12: IP_Addr_If2 / IP_Addr_C1_P1 MD3000i iSCSI Sessions To MD3000i Controller 0 Session 00: T01 Session 01: T02 To MD3000i Controller 1 Session 10: T11 Session 11: T12 Two sessions with one TCP connection are configured from the host to each controller (one session per port), for a total of four sessions. The multi-path failover driver will balance I/O access across the sessions to the ports on the same controller. In a duplex configuration, with virtual disks on each controller, creating sessions using each of the iSCSI data ports of both controllers increases bandwidth and provides load-balancing. 4 Information Update