Dell PowerVault TL4000 Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS bridge iSC
Dell PowerVault TL4000 Manual
View all Dell PowerVault TL4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerVault TL4000 manual content summary:
- Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 1
Dell™ Model TL2000/TL4000 1GB iSCSI to SAS bridge iSCSI initiators Table of Contents Install the iSCSI Initiator Software (iSCSI-attached Host Servers Only 3 Installing the iSCSI Initiator on a Windows Host Server 3 Installing the iSCSI Initiator on a Linux Host Server 3 Installing the iSCSI - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 2
Connect to the TL2000/TL4000 from the Host Server 9 If you are using Windows Server 2008 Core Version discovered by RH5 12 Avoiding duplicate iSCSI devices discovered by RH4 13 Viewing the status of your iSCSI connections 13 Performing Hardware Maintenance with your iSCSI solution 14 Reference - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 3
support.dell.com for the latest version and download location of the Microsoft iSCSI Software Initiator software 2) From the host server, download the iSCSI Initiator software 3) Once the installation begins and the Microsoft iSCSI Initiator Installation setup panel appears, select Initiator Service - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 4
the Server or Client subdirectory. 2) Run the following command: rpm -i /path/to/media/Server/iscsiinitiatorutils.rpm Installing the iSCSI Initiator on a SLES 9 System You can install the iSCSI initiator software on SUSE® Linux Enterprise Servers (SLES) 9 SP3 systems either during or after operating - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 5
Software Installation 23 4) When the open-iscsi and yast2-iscsi-client modules are displayed, select them. 5) Click Accept. Perform Target Discovery from the iSCSI Initiator This step identifies the iSCSI ports on the TL2000/TL4000 Port number. The default is 3260. 5) troubleshooting not supported. e) - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 6
by modifying the /etc/iscsi.conf file, which is installed by default when you installed the iSCSI initiator. The /etc/iscsi.conf file needs From the console, restart the iSCSI service with the following command: service iscsi start 3) Verify that the iSCSI service is running during boot using the - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 7
data or header information be compiled during transmission to assist in troubleshooting. g) CHAP logon information: Enter the target CHAP authentication username IPSec is not supported. 7) Click OK. Using Windows Server 2008 Core Version 1) Set the iSCSI initiator services to start automatically ( - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 8
CHAP node.session.auth.username = iqn.2005-03.com.redhat01.78b1b8cad821 node.session.auth.password = password_1 node.session.auth.username_in= iqn.198405.com.dell:powervault.123456 node.session.auth.password_in = test1234567890 discovery.sendtargets.auth.authmethod = CHAP discovery.sendtargets.auth - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 9
password. 11) Repeat step 7 for each target until at least one connection is logged in for each controller. 12) Go to Connected Targets. 13) Verify that the targets are connected and show a status of true. Connect to the TL2000/TL4000 in troubleshooting. e) IPSec is not supported. 7) Click OK service - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 10
: , and Software Initiator 2.x User's Guide Driver Version ...4:0.1.11-3(02-May-2006 TARGET NAME : iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292 TARGET ALIAS : HOST ID : 2 BUS ID : 0 TARGET ID : 0 TARGET ADDRESS : 192.168.0.110:3260,1 SESSION STATUS - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 11
of each iSCSI port connected to the iSCSI to SAS Bridge. The specific steps depend on whether you are using a Dynamic Host Configuration Protocol (DHCP addressing, Domain Name System (DNS) server, or Windows Internet Name Service (WINS) server. NOTE: The server IP addresses must be configured for - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 12
IP address and netmask of each iSCSI port connected to the .The specific steps depend on whether you are configuring TCP/IP using Dynamic Host network services using the following command: /etc/init.d/network restart Configuring TCP/IP on Linux using a Static IP address (root users only) - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 13
iscsi-kill-session -i 68 If you run the 'iscsi-ls' again, you should only see a single instance for the drive, and a single instance for the library. Note: every time you restart the iscsi services, all the sessions will be opened back up again. Also, the session ID's change, so it will be necessary - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 14
the following: 1) Backup applications are down (close the application or stop the services) 2) Open the iSCSI initiator 3) Log out of the current targets 4) Delete the target IP address targets 5) Perform your HW update 6) Re-configure your iSCSI initiator 7) Re-configure you ISV Note: To delete - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 15
or loss of data and tells you how to avoid the problem. Understanding CHAP Authentication Before proceeding to either Step 5: Configure CHAP Service) Server, supported only on Windows iSCSI environments, eliminates the need to manually configure each individual iSCSI to SAS bridge with a specific - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1GB iSCSI to SAS
bridge iSC - Page 16
Inc. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo are trademarks of Dell Inc.; SUSE is a registered trademark of Novell Inc. in the United States and other countries
Page 1
Dellâ„¢ Model TL2000/TL4000 1GB
iSCSI to SAS bridge iSCSI initiators
Table of Contents
Install the iSCSI Initiator Software (iSCSI-attached Host Servers Only)
.......................................
3
Installing the iSCSI Initiator on a Windows Host Server
............................................................
3
Installing the iSCSI Initiator on a Linux Host Server
..................................................................
3
Installing the iSCSI initiator during RHEL 4 installation
.........................................................
3
Installing the iSCSI initiator after RHEL 4 installation:
...........................................................
3
Installing the iSCSI Initiator on a RHEL 5 System
.....................................................................
4
Installing the iSCSI initiator during RHEL 5 installation:
........................................................
4
Installing the iSCSI initiator after RHEL 5 installation:
...........................................................
4
Installing the iSCSI initiator after RHEL 5 installation via the command line:
........................
4
Installing the iSCSI Initiator on a SLES 9 System
.....................................................................
4
Installing the iSCSI initiator during SLES 9 installation:
.........................................................
4
Installing the iSCSI initiator after SLES 9 installation:
............................................................
4
Installing the iSCSI Initiator on a SLES 10 SP1 System
...........................................................
5
Install the iSCSI initiator during SLES 10 SP1 installation:
....................................................
5
Installing the iSCSI initiator after SLES 10 SP1 installation:
..................................................
5
Perform Target Discovery from the iSCSI Initiator
........................................................................
5
Using Windows Server 2003 or Windows Server 2008 GUI version
.........................................
5
Using Windows Server 2008 Core Version
...............................................................................
6
Using Linux Server
....................................................................................................................
6
Using RHEL 5 or SLES 10 SP1
................................................................................................
6
Configure CHAP Authentication on the Host Server (optional)
.....................................................
7
Using Windows Server 2003 or Windows Server 2008 GUI version
.........................................
7
Using Windows Server 2008 Core Version
...............................................................................
7
Using Linux Server
....................................................................................................................
8
If you are using RHEL 5 or SLES 10 SP1
.................................................................................
8
If you are using SLES10 SP1 via the GUI
.................................................................................
8