Dell Unity 500 Unity SNMP Alert Messages Reference Guide - Page 13

Processor SP. If the I/O module, An I/O module in your Disk

Page 13 highlights

14:603e8 14:603ee 14:603f7 14:603f8 14:603f9 14:6044c 14:6044d 14:60450 14:60451 CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL Platform SNMP Alert Messages An I/O module in your Disk Processor Enclosure has faulted and needs to be replaced. An I/O module in your Disk Processor Enclosure is the wrong model type. Replace it with a supported model. The I/O module is powered off. Try rebooting the Storage Processor (SP). If the I/O module remains powered off after a reboot, you may need to replace the I/O module. The system was unable to power on this I/O module. Replace the I/O module. This I/O module will remain unsupported until the current software version is committed. Reboot the system to commit the software version. The Storage Processor (SP) has faulted. Try rebooting the SP. If the fault persists or occurs repeatedly, the SP needs to be replaced. A Storage Processor is missing and needs to be reinstalled. An issue has occurred with the system software on this Storage Processor (SP). Before you proceed, collect service information. Ensure that the cables are connected securely and not damaged, and then reboot the SP. If rebooting the SP does not resolve the issue, reimage the SP. If the problem still persists, contact your service provider. You may have manually put the Storage Processor (SP) in Service Mode or the SP entered Service %2 has faulted (Part Number %3, Serial Number %4) %2 is not supported %2 is powered off. %2 failed to power on. %2 is not supported. Storage Processor %2 has faulted (Part Number %3, Serial Number %4) Storage Processor %2 has been removed The system software on Storage Processor %2 has encountered a problem Storage Processor %2 has faulted and is in Service TRUE TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE SNMP Alert Messages Reference Guide 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Platform SNMP Alert Messages
13
SNMP Alert Messages Reference Guide
14:603e8
CRITICAL
An I/O module in your Disk
Processor Enclosure has faulted
and needs to be replaced.
%2 has faulted (Part
Number %3, Serial
Number %4)
TRUE
14:603ee
CRITICAL
An I/O module in your Disk
Processor Enclosure is the wrong
model type. Replace it with a
supported model.
%2 is not supported
TRUE
14:603f7
CRITICAL
The I/O module is powered off.
Try rebooting the Storage
Processor (SP). If the I/O module
remains powered off after a
reboot, you may need to replace
the I/O module.
%2 is powered off.
TRUE
14:603f8
CRITICAL
The system was unable to power
on this I/O module. Replace the
I/O module.
%2 failed to power on.
TRUE
14:603f9
CRITICAL
This I/O module will remain
unsupported until the current
software version is committed.
Reboot the system to commit
the software version.
%2 is not supported.
TRUE
14:6044c
CRITICAL
The Storage Processor (SP) has
faulted. Try rebooting the SP. If
the fault persists or occurs
repeatedly, the SP needs to be
replaced.
Storage Processor %2 has
faulted (Part Number %3,
Serial Number %4)
TRUE
14:6044d
CRITICAL
A Storage Processor is missing
and needs to be reinstalled.
Storage Processor %2 has
been removed
FALSE
14:60450
CRITICAL
An issue has occurred with the
system software on this Storage
Processor (SP). Before you
proceed, collect service
information. Ensure that the
cables are connected securely
and not damaged, and then
reboot the SP. If rebooting the
SP does not resolve the issue,
reimage the SP. If the problem
still persists, contact your service
provider.
The system software on
Storage Processor %2 has
encountered a problem
TRUE
14:60451
CRITICAL
You may have manually put the
Storage Processor (SP) in Service
Mode or the SP entered Service
Storage Processor %2 has
faulted and is in Service
TRUE