Dell VNXe3200 Disk Support Matrix - Page 2

Settings, Configuration, Update Software, Software, Software Version

Page 2 highlights

Before installing a new disk in a storage system, use EMC Unisphere® to determine the OE revision running on the storage system. In Unisphere, the OE revision can be found by navigating to Settings --> More Configuration --> Update Software. The OE revision appears on the Software tab in the Software Version dialog box. If this revision is lower than the minimum revision required for the disk, as listed in Table 1 or Table 2, you must upgrade the OE on the storage system before installing the disk. EMC recommends that you upgrade the OE from the Update Software page in EMC Unisphere, though you can use the Unisphere CLI. Note 1: VNXe3200 drives do not support Spin Down. Note 2: All drives listed in this document are RoHS compliant. Table 1 VNXe3200 3.5" 12-Slot Enclosures: Disk Capacity 100 GB 100 GB Model Number (NEBS Model) Part Number NEBS? V6-PS6F-100 (N6-PS6F-200) 005050427 005050873 005050506 005051392 005051391 005052190 005052191 005053279 005053280 YES YES YES NO NO YES YES YES YES 005050424 V6-PS6FX-100 (N6-PS6FX-100) 005050537 005051802 005051801 005052201 YES YES NO NO YES Drive Type Spindle Speed Platform Minimum OE Software Revision 6Gb SAS SSD N/A VNXe3200 3.0.0.2960754 6Gb SAS SSD N/A VNXe3200 3.0.0.2960754 2 VNXe Series Storage Systems Disk and OE Matrix

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

2
VNXe Series Storage Systems Disk and OE Matrix
Before installing a new disk in a storage system, use EMC Unisphere
®
to
determine the OE revision running on the storage system. In Unisphere,
the OE revision can be found by navigating to
Settings
-->
More
Configuration
-->
Update Software
. The OE revision appears on the
Software
tab in the
Software Version
dialog box. If this revision is
lower than the minimum revision required for the disk, as listed in Table
1 or Table 2, you must upgrade the OE on the storage system before
installing the disk. EMC recommends that you upgrade the OE from the
Update Software
page in EMC Unisphere, though you can use the
Unisphere CLI.
Note 1: VNXe3200 drives do not support Spin Down.
Note 2: All drives listed in this document are RoHS compliant.
Table 1
VNXe3200
3.5”
12-Slot Enclosures:
Disk
Capacity
Model
Number
(NEBS Model)
Part
Number
NEBS?
Drive
Type
Spindle
Speed
Platform
Minimum OE
Software
Revision
100 GB
V6-PS6F-100
(N6-PS6F-200)
005050427
005050873
005050506
005051392
005051391
005052190
005052191
005053279
005053280
YES
YES
YES
NO
NO
YES
YES
YES
YES
6Gb SAS
SSD
N/A
VNXe3200
3.0.0.2960754
100 GB
V6-PS6FX-100
(N6-PS6FX-100)
005050424
005050537
005051802
005051801
005052201
YES
YES
NO
NO
YES
6Gb SAS
SSD
N/A
VNXe3200
3.0.0.2960754