Denon AVR-2106 Serial Protocol - Page 10
EVENTor RESPONSE and PARAMETER list
View all Denon AVR-2106 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
EVENT(or RESPONSE) and PARAMETER list EVENT PW MV CV PARAMETER ON STANDBY ** FL ** FR ** function POWER ON/STANDBY change MASTER VOLUME change , **:00 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB 00 = -80dB 99 = ---(MIN) CHANNEL VOLUME change , **:00,32 to 62 by ASCII 62 = +12dB(MAX) example PWON PWSTANDBY MV80 CVFL 50 CVFR 50 C ** SW ** SL ** SR ** SBL ** 50 = 0dB 38 = -12dB(MIN) 00 = OFF (define ONLY SWch.) (at SBch 2SP) CVC 50 CVSW 50 CVSL 50 CVSR 50 CVSBL 50 SBR ** (at SBch 2SP) SB ** (at SBch 1SP) MU ON OUTPUT MUTE ON/OFF change CVSBR 50 CVSB 50 MUON OFF SI PHONO INPUT source change MUOFF SIPHONO CD TUNER DVD ---Select DVD/VDP function at AVR-2106 SICD SITUNER SIDVD VDP TV DBS/SAT VCR-1 VCR-2 ---Invalid at AVR-2106 ---Select TV/DBS function at AVR 2106 ---Invalid at AVR-2106 SIVDP SITV SIDBS/SAT SIVCR-1 SIVCR-2 VCR-3 V.AUX CDR/TAPE1 ---Invalid at AVR-2106 ---Select CDR/TAPE function at AVR-2106 SIVCR-3 SIV.AUX SICDR/TAPE1 MD/TAPE2 ---Invalid at AVR-2106 SIMD/TAPE2 *RES. : NOT returns '*' parameters as RESPONSE. The PARAMETER of MV , CV COMMAND : "*" parameter uses two or three ASCII characters. (see page4 (J) section) *RES. -247-