Denon AVR-3803 Serial Protocol - Page 10

Z2OFF<CR&gt

Page 10 highlights

EVENT ZM Z1 Z2 SR TF PARAMETER ON OFF PHONO | CDR/TAPE1 SOURCE ** ON OFF PHONO | CDR/TAPE1 SOURCE ** ON OFF PHONO | CDR/TAPE1 SOURCE ****** (6 digits) function MAIN-ZONE ON/OFF change MULTI ZONE-1 source change ---The name of PARAMETER is the same as that of the time of SI COMMAND. MULTI ZONE-1 mode cancel MULTI ZONE-1 VOLUME change , **:00 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB 10 = -70dB 00 = ---(MIN) MULTI ZONE-1 ON/OFF change ---means MULTI ZONE functions at AVR-2803/3803 MULTI ZONE-2 source change ---The name of PARAMETER is the same as that of the time of SI COMMAND. MULTI ZONE-2 mode cancel MULTI ZONE-2 VOLUME change , **:00 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB 10 = -70dB 00 = ---(MIN) MULTI ZONE-2 ON/OFF change ---Invalid at AVR-2803/3803 REC SELECT source change ---The name of PARAMETER is the same as that of the time of SI COMMAND. REC SELECT mode cancel TUNER Frequency change kHz at AM band ****.** MHz at FM band example ZMON ZMOFF Z1PHONO | Z1CDR/TAPE1 Z1SOURCE Z180 Z1ON Z1OFF Z2PHONO | Z2CDR/TAPE1 Z2SOURCE Z280 Z2ON Z2OFF SRPHONO | SRCDR/TAPE1 SRSOURCE TF105000 (1050.00kHz at AM) *RES. * * * * * * - 10 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

- 10 -
EVENT
PARAMETER
function
example
*RES.
ZM
ON
MAIN-ZONE ON/OFF change
ZMON<CR>
OFF
ZMOFF<CR>
Z1
PHONO
MULTI ZONE-1 source change
Z1PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND. Z1CDR/TAPE1<CR>
SOURCE
MULTI ZONE-1 mode cancel
Z1SOURCE<CR>
**
MULTI ZONE-1 VOLUME change , **:00 to 99 by ASCII
Z180<CR>
*
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
00 = ---(MIN)
ON
MULTI ZONE-1 ON/OFF change
Z1ON<CR>
*
OFF
Z1OFF<CR>
*
---means MULTI ZONE functions at AVR-2803/3803
Z2
PHONO
MULTI ZONE-2 source change
Z2PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND. Z2CDR/TAPE1<CR>
SOURCE
MULTI ZONE-2 mode cancel
Z2SOURCE<CR>
**
MULTI ZONE-2 VOLUME change , **:00 to 99 by ASCII
Z280<CR>
*
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
00 = ---(MIN)
ON
MULTI ZONE-2 ON/OFF change
Z2ON<CR>
*
OFF
Z2OFF<CR>
*
---Invalid at AVR-2803/3803
SR
PHONO
REC SELECT source change
SRPHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND. SRCDR/TAPE1<CR>
SOURCE
REC SELECT mode cancel
SRSOURCE<CR>
TF
****** (6 digits) TUNER Frequency change
TF105000<CR>
--- ****.** kHz at AM band
(1050.00kHz at AM)
****.** MHz at FM band