Denon AVR 3806 Serial Protocol - Page 6

Command, Parameter

Page 6 highlights

COMMAND PARAMETER function example CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP SB DOWN CVSB DOWN SB ** **:00 to 99 by ASCII , 50=0dB CVSB 50 MU ON OUTPUT MUTE ON/OFF change MUON OFF MUOFF SI PHONO Select INPUT source SIPHONO CD SICD TUNER SITUNER DVD SIDVD VDP SIVDP TV SITV DBS SIDBS VCR-1 SIVCR-1 VCR-2 SIVCR-2 VCR-3 ---Invalid at AVR-3806 SIVCR-3 V.AUX SIV.AUX CDR/TAPE SICDR/TAPE ZM ON MAIN-ZONE ON/OFF change at AVR-3806 ZMON OFF ZMOFF Z2 PHONO MULTI ZONE-2 mode set , and select source at AVR-3806 Z2PHONO | ---The name of PARAMETER is | CDR/TAPE the same as that of the time of SI COMMAND. Z2CDR/TAPE SOURCE MULTI ZONE-2 mode cancel at AVR-3806 Z2SOURCE UP MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB Z2UP DOWN at AVR-3806 Z2DOWN ** **:10 to 99 by ASCII , 80=0dB, 99=---(MIN) Z280 ON MULTI ZONE-2 ON/OFF change at AVR-3806 Z2ON OFF Z2OFF Z2MU ON ZONE2 OUTPUT MUTE ON/OFF change Z2MUON OFF Z2MUOFF CV , Z2 COMMAND : "*" parameter uses two ASCII characters. (see page4 J) section) - 6 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

- 6 -
COMMAND
PARAMETER
function
example
CV
SB UP
---SURROUND BACKch
(SBch 1SP)
CVSB UP<CR>
SB DOWN
CVSB DOWN<CR>
SB **
**:00 to 99 by ASCII , 50=0dB
CVSB 50<CR>
MU
ON
OUTPUT MUTE ON/OFF change
MUON<CR>
OFF
MUOFF<CR>
SI
PHONO
Select INPUT source
SIPHONO<CR>
CD
SICD<CR>
TUNER
SITUNER<CR>
DVD
SIDVD<CR>
VDP
SIVDP<CR>
TV
SITV<CR>
DBS
SIDBS<CR>
VCR-1
SIVCR-1<CR>
VCR-2
SIVCR-2<CR>
VCR-3
---Invalid at AVR-3806
SIVCR-3<CR>
V.AUX
SIV.AUX<CR>
CDR/TAPE
SICDR/TAPE<CR>
ZM
ON
MAIN-ZONE ON/OFF change at AVR-3806
ZMON<CR>
OFF
ZMOFF<CR>
Z2
PHONO
MULTI ZONE-2 mode set , and select source at AVR-3806 Z2PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE
the same as that of the time of SI COMMAND. Z2CDR/TAPE
SOURCE
MULTI ZONE-2 mode cancel at AVR-3806
Z2SOURCE<CR>
UP
MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB
Z2UP<CR>
DOWN
at AVR-3806
Z2DOWN<CR>
**
**:10 to 99 by ASCII , 80=0dB, 99=---(MIN)
Z280<CR>
ON
MULTI ZONE-2 ON/OFF change at AVR-3806
Z2ON<CR>
OFF
Z2OFF<CR>
Z2MU
ON
ZONE2 OUTPUT MUTE ON/OFF change
Z2MUON<CR>
OFF
Z2MUOFF<CR>
CV , Z2
COMMAND
: "*" parameter uses two
ASCII characters. (see page4 J) section)