Denon POA-3012CI Serial Protocol

Denon POA-3012CI - Multi-Zone Audio Distribution Power Amplifier Manual

Denon POA-3012CI manual content summary:

  • Denon POA-3012CI | Serial Protocol - Page 1
    DENON control protocol Application model : POA-3012CI Application terminal: RS-232C/ Ethernet Connector specification Ⅰ. RS-232C Connector type: DB-9pin female type, slave straight connection (DCE type) ( 1pin : GND , 2pin : TxD , 3pin :
  • Denon POA-3012CI | Serial Protocol - Page 2
    Connector type : RJ-45(10BASE-T/100BASE-TX) Example ① Ethernet PC Cross cable POA-3012CI Example ② PC HUB Ethernet Straight cable Ethernet Straight cable POA-3012CI Communication format : Communication system Communication speed Communication port Communication data length : A half
  • Denon POA-3012CI | Serial Protocol - Page 3
    configuration", then Menu appears on FL-display. (2)Set parameters described below. "ON LINE"---Use this setting when using the POA-3012CI connected in a network. "MASTER TRIGGER" or "POWER BUTTON"--- Use this setting when not using the POA-3012CI connected in a network. This setting is reducing the
  • Denon POA-3012CI | Serial Protocol - Page 4
    to a controller (Touch Panel etc.) from a system (POA-3012CI) The result is sent, when a system is operated expression *ASCII CODE which can be used is from 0x20 to 0x7F: the alphabet and the number PW : system Power setting CHANNEL : ASCII CODE of 2 characters (00 to 12) Ex. 09 : channel number 00
  • Denon POA-3012CI | Serial Protocol - Page 5
    of 0x0D. SI09BUSL : Select Input source "BUS L" at channel 9. SO06BRIDGED : Set Operation Mode to bridged mode at channel 5 & 6. SV02UP : Master Volume UP at channel 2. PW00ON : system PoWer ON PW00STANDBY : system PoWer STANDBY SI04? : Request command for now playing
  • Denon POA-3012CI | Serial Protocol - Page 6
    of MASTER VOLUME defines "99". D) If the MASTER VOLUME & CHANNEL VOLUME set with 0.5dB step, the PARAMETER (with COMMAND and RESPONSE SV00 ---.-dB : SV99 * At the **.0dB step, only uses two ASCII characters as PARAMETER, same as usual. K) Four seconds later, please transmit
  • Denon POA-3012CI | Serial Protocol - Page 7
    ONLI ON LINE ST00ONLI ? Return Power ON status ST00? SV COMMAND : "*" parameter uses two or three ASCII characters. (see page6 D) section) *01-12 : The ZONE that "Normal mode" was selected, odd and even CHANNEL selectable. If the ZONE that "BRIDGED mode" was selected, only an
  • Denon POA-3012CI | Serial Protocol - Page 8
    SD 00 TI 02-12(EVEN) 00 AI 02-12(EVEN) PR 00 02-12(EVEN) PARAMETER BRI DIM DAR OFF ? ? ? ? TR? IN? TM? PR? OH? function FL display's dimmer level change Return dimmer status Return channel trigger input Return master trigger inputs Return channel audio signal input Return system(Main
  • Denon POA-3012CI | Serial Protocol - Page 9
    ) YES NO 00 YES NO AI 02-12(EVEN) YES NO 90 = 0dB(MAX) 00 = -90dB 99 = ---(MIN) OPERATION MODE change Channel Low Cut Filter OFF/ON change Channel INPUT source change Zone turn on mode change Power configuration change Dimmer level change Zone trigger input YES/NO change Master trigger input
  • Denon POA-3012CI | Serial Protocol - Page 10
    EVENT PR CHANNEL 00 02-12(EVEN) PARAMETER TROHWARN TROHNONE INOHWARN INOHNONE TMOHTR01****** TMOHTR02****** | TMOHTR20****** TMOHIN01 , 001120 = 11hour20min ZONE POWER MODULE PROTECTION WARNING ZONE POWER MODULE PROTECTION NONE ZONE POWER MODULE OVER HEAT WARNING ZONE POWER MODULE OVER HEAT NONE
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

- 1 -
DENON control protocol
Ver. 5.1.7
Application model :
POA-3012CI
Application terminal: RS-232C/
Ethernet
Connector specification
. RS-232C
Connector type:
DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format:
Synchronous system
: Tone step synchronization
Communication system
: A half duplex
Communication speed
: 9600bps
Character length
: 8 bits
Parity control
: None
Start bit
: 1 bit
Stop bit
: 1 bit
Communication procedure
: Non procedural
Communication data length
: 135 bytes (maximum)