Denon POA-3012CI Serial Protocol - Page 7
COMMAND and PARAMETER list - 12 channel
![]() |
UPC - 083795000196
View all Denon POA-3012CI manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
COMMAND and PARAMETER list COMMAND CHANNEL PARAMETER function example PW 00 ON POWER ON/STANDBY change PW00ON STANDBY PW00STANDBY ? Return PW Status PW00? SV *01-12 UP CHANNEL VOLUME UP/DOWN , direct change to **dB SV01UP DOWN SV01DOWN ** **:00 to 99 by ASCII , 90=0dB, 99=---(MIN) SV0180 ? Return channel volume Status SV01? SO 02-12(EVEN) NOR Operation mode NORMAL/BRIDGED change SO02NOR BRI SO02BRI ? Return operation mode status SO02? SF *01-12 OFF Channel Low Cut Filter OFF/ON change SF05OFF ON SF05ON ? Return channel Low Cut Filter status SF05? SI *01-12 BUSL Select input "BUS L" SI06BUSL BUSR BUS R SI06BUSR BUSM BUS MONO(L+R) SI06BUSM AUX AUX SI06AUX ? Return channel Input status SI06? ST 02-12(EVEN) CONT constant ST08CONT TRIG Trigger in ST08TRIG ASIG Audio signal ST08ASIG OFF Off ST08OFF ? Return Zone Turn On status ST08? 00 PBTN Power button ST00PBTN TRIG MASTER TRIGGER ST00TRIG ONLI ON LINE ST00ONLI ? Return Power ON status ST00? SV COMMAND : "*" parameter uses two or three ASCII characters. (see page6 D) section) *01-12 : The ZONE that "Normal mode" was selected, odd and even CHANNEL selectable. If the ZONE that "BRIDGED mode" was selected, only an even number CHANNEL selectable. - 7 -