EMC CX600 Configuration Guide - Page 74

Windows 2000 Single Fabric Connections

Page 74 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Windows 2000 Single Fabric Connections See General Configuration Rules (page 6) and Switch Topology Rules (page 20). Servers: Multiple with same or different operating systems. See Fan-Out Rule (page 9), Paths from a Server to an SP (page 10), Clustered Server Configuration Rules (page 14), Failover Configuration Rules (page 15). Storage Systems: Multiple CX200, CX400, CX600, FC4500, FC4700, or FC5300 (FC5300 configuration available from selected channels; MIA required for optical connect). See Fan-In Rule (page 9). For the failover software supported for a storage system, see Failover Configuration Rules (page 15). Fabric: See Storage Area Network (SAN) Configuration Rules (page 9) and General Switch Topology Rules (page 20). Configurations: Storage Systems CX200 CX400 CX600 FC4500 FC4700 FC5300 CX200 CX400 CX600 FC4700 CX200 CX400 CX600 FC4500 FC4700 FC5300 CX400 CX600 FC4700 CX200 CX400 CX600 FC4500 FC4700 FC5300 CX400 CX600 FC4700 Servers Single Multiple Multiple Multiple Multiple Multiple HBAs Ports per Server Multiple Multiple 1 1 PowerPath, ATF multiple PowerPath Base - 1 or 2 Utility Kit PowerPath, CDE - 1 PowerPath, ATF multiple PowerPath Base - 1 or 2 Utility Kit PowerPath, CDE - 1 Ports Used per SP PowerPath - multiple, except for CX200, FC4500, FC5300 ATF- multiple (FC4700) or 1 (FC4500, FC5300) PowerPath Base - 1 PowerPath - multiple except for CX200 ATF- multiple PowerPath Base - 1 1 PowerPath, ATF multiple Utility Kit PowerPath, CDE - 1 PowerPath - multiple except for CX200, FC4500, FC5300 ATF- multiple (FC4700) or 1 (FC4500, FC5300) PowerPath Base, Utility Kit PowerPath, CDE - 1 PowerPath, ATF - multiple Utility Kit PowerPath, CDE - 1 Requirements/Comments PowerPath, PowerPath Base, or ATF. Optional multiple paths from server to each SP. Clusters not applicable. Access Logix required for CX200, FC4500, FC5300, and optional SnapView (CX400, CX600, FC4700). PowerPath, PowerPath Base, or ATF. Clusters required. Access Logix required for optional SnapView (CX400, CX600, FC4700) and optional MirrorView (CX400, CX600, FC4700). PowerPath, PowerPath Base, Utility Kit PowerPath, ATF, or CDE. Clusters optional for servers - Microsoft Cluster Server or Oracle9iRAC. Access Logix, optional SnapView (CX400, CX600, FC4700), optional MirrorView (CX400, CX600, FC4700). PowerPath, Utility Kit PowerPath, ATF, or CDE. Clusters optional - Microsoft Cluster Server or Oracle9iRAC. Access Logix, optional SnapView, optional MirrorView. PowerPath, PowerPath Base, Utility Kit PowerPath, ATF, or CDE. Clusters optional for servers - Microsoft Cluster Server or Oracle9iRAC. Access Logix, optional SnapView (CX400, CX600, FC4700), optional MirrorView (CX400, CX600, FC4700). PowerPath, PowerPath Base, Utility Kit PowerPath, ATF, or CDE. Optional multiple paths from multiple HBA-port non-clustered server to each SP. Clusters optional - Microsoft Cluster Server or Oracle9iRAC. Access Logix, optional SnapView, optional MirrorView. Diagrams 1 on page 89 2 on page 90 3 on page 91 4 on page 92 5 on page 93 6 on page 95 Document Rev 19 Page 74 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 74
EMC Confidential
Windows 2000 Single Fabric Connections
See
General Configuration Rules
(page 6) and
Switch Topology Rules
(page 20).
Servers:
Multiple with same or different operating systems.
See
Fan-Out Rule
(page 9),
Paths from a Server to an SP (
page 10
)
,
Clustered Server Configuration Rules
(page 14),
Failover Configuration Rules
(page 15).
Storage Systems:
Multiple
CX200, CX400, CX600, FC4500, FC4700, or FC5300 (FC5300 configuration available from
selected channels; MIA required for optical connect).
See
Fan-In Rule
(page 9). For the failover software supported for a storage system, see
Failover Configuration Rules
(page 15).
Fabric:
See
Storage Area Network (SAN) Configuration Rules
(page 9) and
General Switch Topology Rules
(page 20).
Configurations:
Storage
Systems
Servers
HBAs Ports
per Server
Ports Used
per SP
Requirements/Comments
Diagrams
CX200
CX400
CX600
FC4500
FC4700
FC5300
Single
Multiple
PowerPath - multiple,
except for CX200,
FC4500, FC5300
ATF- multiple
(FC4700) or
1 (FC4500, FC5300)
PowerPath Base - 1
PowerPath, PowerPath Base, or ATF.
Optional multiple paths from server to each SP.
Clusters not applicable.
Access Logix required for CX200, FC4500, FC5300, and
optional SnapView (CX400, CX600, FC4700).
1 on page 89
CX200
CX400
CX600
FC4700
Multiple
Multiple
PowerPath - multiple
except for CX200
ATF- multiple
PowerPath Base - 1
PowerPath, PowerPath Base, or ATF.
Clusters required.
Access Logix required for optional SnapView
(CX400,
CX600, FC4700) and optional MirrorView (CX400,
CX600, FC4700).
2 on page 90
CX200
CX400
CX600
FC4500
FC4700
FC5300
Multiple
1
1
PowerPath, PowerPath Base, Utility Kit PowerPath, ATF, or
CDE.
Clusters optional for servers
- Microsoft Cluster Server or
Oracle9iRAC.
Access Logix, optional SnapView (CX400, CX600,
FC4700),
optional MirrorView (CX400, CX600, FC4700)
.
3 on page 91
CX400
CX600
FC4700
Multiple
1
PowerPath, ATF -
multiple
Utility Kit PowerPath,
CDE - 1
PowerPath, Utility Kit PowerPath, ATF, or CDE.
Clusters optional - Microsoft Cluster Server or
Oracle9iRAC.
Access Logix, optional SnapView, optional MirrorView.
4 on page 92
CX200
CX400
CX600
FC4500
FC4700
FC5300
Multiple
PowerPath, ATF -
multiple
PowerPath Base - 1 or
2
Utility Kit PowerPath,
CDE - 1
PowerPath - multiple
except for CX200,
FC4500, FC5300
ATF- multiple
(FC4700) or
1 (FC4500, FC5300)
PowerPath Base,
Utility Kit PowerPath,
CDE - 1
PowerPath, PowerPath Base, Utility Kit PowerPath, ATF, or
CDE.
Clusters optional for servers - Microsoft Cluster Server or
Oracle9iRAC.
Access Logix, optional SnapView (CX400, CX600,
FC4700), optional MirrorView (CX400, CX600, FC4700).
5 on page 93
CX400
CX600
FC4700
Multiple
PowerPath, ATF -
multiple
PowerPath Base - 1
or 2
Utility Kit PowerPath,
CDE - 1
PowerPath, ATF -
multiple
Utility Kit PowerPath,
CDE - 1
PowerPath,
PowerPath Base
, Utility Kit PowerPath, ATF, or
CDE.
Optional multiple paths from multiple HBA-port
non-clustered server to each SP.
Clusters optional - Microsoft Cluster Server or
Oracle9iRAC.
Access Logix, optional SnapView, optional MirrorView.
6 on page 95