EdgeStar AP550Z Owner's Manual - Page 6

Electrical, Control, panel

Page 6 highlights

Electrical Control panel ATA4 4. &A ZIT sia *:lima ON/OFF. Starts or Stops the appliance If power to the unit is interrupted, the unit will re-start automatically3 minutes after power is resumed. NOTE: If the Unit "beeps" several times in a row and the power light blinks, the internal safety shut-off has been activated and the unit must be drained. This is a rare occurrence and should rarely or never happen. MODE Control: Select the functions of the unit for: AUTO, COOL, DRY and HEAT. The appliance will go AUTO function the first time it is switched on and will remain in this mode until another program is chosen. AUTO (automatic mode): press the MODE key to select AUTO, and the microprocessor will select an ideal temperature and optimal function. "AUTO" is shown on the display and the light comes on. If the temperature of room is 76°F or above, "COOL" mode is activated automatically and the optimal fan speed is activated. If the room temperature is 75°F or below, the "FAN" mode is selected automatically and the optimal fan speed is activated. COOL (cooling mode): press the MODE key to select COOL and the "COOL" light will come on. USE the "UP" and "DOWN" keys to set the temperature desired. If the room temperature is higher than that selected, the appliance activates cooling. The compressor will start after 3minutes (during which only the ventilation function is active) If the room temperature is lower than that selected, the appliance activates the ventilation function. DRY (dehumidification mode): press the MODE key to select DRY and the "DRY" light comes on. The compressor will start and run for 10 minutes and stop for 4 minutes. The fan will go into middle speed first and thereafter the speed is adjustable. HEAT (heating mode): This is an optional function for appliances with heat pumps. Press the MODE key to select HEAT, and the "HEAT" light comes on. USE the "UP" and "DOWN" keys to set the temperature required. If the temperature of the air in the room is lower than that selected, the appliance activates the heating. SPEED option: press the "SPEED" key to adjust the fan speed (High/Medium) TIMER (timer mode) press the timer to program time and the "TIMER" light comes on while the timer is programmed. Before programming, make sure that the timer function has not been activated (the light must be off)! The following timer programs are available. a) Delayed power-on function (when the appliance is in stand-by [off] status) USE the "TIMER" keys to set the time period (0-24 hours) The appliance will start once time reaches setting value. b) Delayed power-off function (the appliances is in working status) The appliance will stop once time reach setting value. SLEEP (sleeping mode): To select "SLEEP", press the "SLEEP" key and the light will come on. Once the SLEEP function is selected, the selected temperature required will be increase by 2°F each hour to maximum of 4°F over two hours and then maintain at that temperature for the balance of the time set. OSC. (oscillating function): press the MODE key to select OSC. and the "OSC" light comes on. Once the OSC is selected, louvers will be oscillating from left and right automatically. WATER EVAPORATION. This appliance has a built-in Z-spray condensate exhaust system. All water collected under normal operating conditions will be evaporated out the exhaust hose. Please note this means that the air coming out of the exhaust hose will be laden with water vapor and moisture droplets. Be mindful of this when choosing your location to vent this hot air. Additionally, if the self-evaporation system is overcome by excessive moisture, the air conditioner will automatically shut off. The power light will blink and the air conditioner will beep repeatedly. Drain the tank by removing the black drain plug on the rear of the unit to restore normal operation.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Electrical
Control
panel
A
TA
4
4
.
ZIT
&A
s
ia
:lima
*
ON/OFF.
Starts
or
Stops
the
appliance
If
power
to
the
unit
is
interrupted,
the
unit
will
re
-start
automatically3
minutes
after
power
is
resumed.
NOTE:
If
the
Unit
"beeps"
several
times
in
a
row
and
the
power
light
blinks,
the
internal
safety
shut-off
has
been
activated
and
the
unit
must
be
drained.
This
is
a
rare
occurrence
and
should
rarely
or
never
happen.
MODE
Control:
Select
the
functions
of
the
unit
for:
AUTO,
COOL,
DRY
and
HEAT.
The
appliance
will
go
AUTO
function
the
first
time
it
is
switched
on
and
will
remain
in
this
mode
until
another
program
is
chosen.
AUTO
(automatic
mode):
press
the
MODE
key
to
select
AUTO,
and
the
microprocessor
will
select
an
ideal
temperature
and
optimal
function.
"AUTO"
is
shown
on
the
display
and
the
light
comes
on.
If
the
temperature
of
room
is
76
°
F
or
above,
"COOL"
mode
is
activated
automatically
and
the
optimal
fan
speed
is
activated.
If
the
room
temperature
is
75
°
F
or
below,
the
"FAN"
mode
is
selected
automatically
and
the
optimal
fan
speed
is
activated.
COOL
(cooling
mode):
press
the
MODE
key
to
select
COOL
and
the
"COOL"
light
will
come
on.
USE
the
"UP"
and
"DOWN"
keys
to
set
the
temperature
desired.
If
the
room
temperature
is
higher
than
that
selected,
the
appliance
activates
cooling.
The
compressor
will
start
after
3minutes
(during
which
only
the
ventilation
function
is
active)
If
the
room
temperature
is
lower
than
that
selected,
the
appliance
activates
the
ventilation
function.
DRY
(dehumidification
mode):
press
the
MODE
key
to
select
DRY
and
the
"DRY"
light
comes
on.
The
compressor
will
start
and
run
for
10
minutes
and
stop
for
4
minutes.
The
fan
will
go
into
middle
speed
first
and
thereafter
the
speed
is
adjustable.
HEAT
(heating
mode):
This
is
an
optional
function
for
appliances
with
heat
pumps.
Press
the
MODE
key
to
select
HEAT,
and
the
"HEAT"
light
comes
on.
USE
the
"UP"
and
"DOWN"
keys
to
set
the
temperature
required.
If
the
temperature
of
the
air
in
the
room
is
lower
than
that
selected,
the
appliance
activates
the
heating.
SPEED
option:
press
the
"SPEED"
key
to
adjust
the
fan
speed
(High/Medium)
TIMER
(timer
mode)
press
the
timer
to
program
time
and
the
"TIMER"
light
comes
on
while
the
timer
is
programmed.
Before
programming,
make
sure
that
the
timer
function
has
not
been
activated
(the
light
must
be
off)!
The
following
timer
programs
are
available.
a)
Delayed
power
-on
function
(when
the
appliance
is
in
stand-by
[off]
status)
USE
the
"TIMER"
keys
to
set
the
time
period
(0-24
hours)
The
appliance
will
start
once
time
reaches
setting
value.
b)
Delayed
power
-off
function
(the
appliances
is
in
working
status)
The
appliance
will
stop
once
time
reach
setting
value.
SLEEP
(sleeping
mode):
To
select
"SLEEP",
press
the
"SLEEP"
key
and
the
light
will
come
on.
Once
the
SLEEP
function
is
selected,
the
selected
temperature
required
will
be
increase
by
2
°
F
each
hour
to
maximum
of
4
°
F
over
two
hours
and
then
maintain
at
that
temperature
for
the
balance
of
the
time
set.
OSC.
(oscillating
function):
press
the
MODE
key
to
select
OSC.
and
the
"OSC"
light
comes
on.
Once
the
OSC
is
selected,
louvers
will
be
oscillating
from
left
and
right
automatically.
WATER
EVAPORATION.
This
appliance
has
a
built-in
Z
-spray
condensate
exhaust
system.
All
water
collected
under
normal
operating
conditions
will
be
evaporated
out
the
exhaust
hose.
Please
note
this
means
that
the
air
coming
out
of
the
exhaust
hose
will
be
laden
with
water
vapor
and
moisture
droplets.
Be
mindful
of
this
when
choosing
your
location
to
vent
this
hot
air.
Additionally,
if
the
self
-evaporation
system
is
overcome
by
excessive
moisture,
the
air
conditioner
will
automatically
shut
off.
The
power
light
will
blink
and
the
air
conditioner
will
beep
repeatedly.
Drain
the
tank
by
removing
the
black
drain
plug
on
the
rear
of
the
unit
to
restore
normal
operation.