1. Operating Environment This switch must be installed and operated within the operating limits of temperature (0 to 40°C, 32 to 104°F) and humidity (10 to 90% non-condensing).  Do not place objects on top of the unit.  Do not obstruct any vents on the sides of the unit.  Do not position the unit near any heat sources, such as heaters, radiators, or direct exposure to the sun. Prevent water and moisture from entering the unit. If necessary, use a dehumidifier to reduce humidity. 2. Connecting to network devices The RJ-45 ports on the switch support auto-MDI/MDIX, which allows straight-through cross-over type cables to connect this switch to a workstation or hub. Connect one end of the network cable to the RJ-45 port on the rear panel, and connect the other end of the network cable to the RJ-45 port on the network device. Follow the same procedure to connect other RJ-45 ports on the switch. The UTP network cables must comply with EIA/TIA 568 specifications and Category 5 standards for data transmission. Maximum length for UTP cable is 100 meters (300 feet) between the switch and connected devices. Once the network cable is connected at both ends and the attached network device is powered on, the green LINK/ACT LED should be lit. 3. Connecting the power Connect the power adapter to the power connector of the unit; the green Power LED on the front panel should be lit.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

1.
Operating Environment
This switch must be installed and operated within the operating limits of
temperature (0 to 40
°
C, 32 to 104
°
F) and humidity (10 to 90%
non-condensing).
Do not place objects on top of the unit.
Do not obstruct any vents on the sides of the unit.
Do not position the unit near any heat sources, such as heaters, radiators,
or direct exposure to the sun.
Prevent water and moisture from entering the unit. If necessary, use a
dehumidifier to reduce humidity.
2.
Connecting to network devices
The RJ-45 ports on the switch support auto-MDI/MDIX, which allows
straight-through cross-over type cables to connect this switch to a workstation
or hub.
Connect one end of the network cable to the RJ-45 port on the rear panel, and
connect the other end of the network cable to the RJ-45 port on the network
device. Follow the same procedure to connect other RJ-45 ports on the switch.
The UTP network cables must comply with EIA/TIA 568 specifications and
Category 5 standards for data transmission. Maximum length for UTP cable is
100 meters (300 feet) between the switch and connected devices.
Once the network cable is connected at both ends and the attached network
device is powered on, the green LINK/ACT LED should be lit.
3.
Connecting the power
Connect the power adapter to the power connector of the unit; the green
Power LED on the front panel should be lit.