Electrolux E30EC65ESS Specification sheet - Page 2

Electrolux Major Appliances, N.A. - specifications

Page 2 highlights

Electric Drop-In Cooktop E30EC65ESS 30 3/4" 13" max. cabinet depth 30 3/4" Side inset 3/8" 2" min. recommended 10" distance between rear edge of cutout and nearest combustible 4" x 8" opening to route armored cable surface above countertop 12" 21 1/2" 30" min. for unprotected cabinet 24" min. for protected surface 4" 18" min. 6" min. 7 1/2" min. to nearest combustible wall (either side of unit) 20 1/4" min. 25" min. 20 1/2" max. 2 1/2" 24" max. Approximate location of junction box 29 5/8" min. 30" max. 30" Electric Drop-In Cooktop Specifications • Product Weight - 35 Lbs. • Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. • Connected Load (kW Rating) @ 240 / 208 Volts = 8.76 / 6.58 kW • Amps @ 240 / 208 Volts = 36.2 / 31.4 Amps • Always consult local and national electric codes. • Allow 2" space below armored cable opening to clear electrical cable and allow space for installation of junction box on wall at back of cooktop. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 2" minimum clearance between rear edge of cutout and nearest combustible surface above countertop. • Allow 7-1/2" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • It is recommended that drawers not be used beneath cooktop. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Electric Drop-In Cooktop model E30EC65ESS is NOT approved to be used over any Electrolux ICON® Single Wall Oven. • Electric Drop-In Cooktop model E30EC65ESS is approved to be used in combination with an Electrolux ICON® 30" Downdraft Vent. (Refer to Drop-In Cooktop / Downdraft Vent Countertop Preparation page on web for detailed installation specifications.) Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Optional Accessories • Granite Countertop Installation Kit - (PN # 903061-9010). Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E30EC65ESS 04/10 © 2010 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2
  • 3

Electric Drop-In Cooktop
E30EC65ESS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E30EC65ESS
04/10
© 2010 Electrolux Home Products, Inc.
Printed in the U.S.A.
30" Electric Drop-In Cooktop Specifications
Product Weight – 35 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz AC
only electrical supply with ground required on separate circuit fused on
both sides of line.
Connected Load (kW Rating) @ 240/208 Volts = 8.76/6.58kW
Amps @ 240/208 Volts = 36.2/31.4 Amps
Always consult local and national electric codes.
Allow 2" space below armored cable opening to clear electrical
cable and allow space for installation of junction box on wall at back
of cooktop.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 2" minimum clearance between rear edge of cutout and nearest
combustible surface above countertop.
Allow 7-1/2" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Electric Drop-In Cooktop model E30EC65ESS is NOT approved to be
used over any Electrolux ICON
®
Single Wall Oven.
Electric Drop-In Cooktop model E30EC65ESS is approved to be used in
combination with an Electrolux ICON
®
30” Downdraft Vent.
(Refer to
Drop-In Cooktop/Downdraft Vent Countertop Preparation page on web
for detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN# 903061-9010).
29
5
/
8
"min.
30"max.
4"
6" min.
25"min.
30
3
/
4
"
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
24"
2" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
20
1
/
4
" min.
20
1
/
2
" max.
2
1
/
2
"
max.
21
1
/
2
"
30
3
/
4
"
10"
12"
Side inset
3
/
8
"
Approximate location
of junction box
4"x 8" opening to route
armored cable