Electrolux E30GC70FSS Specification sheet - Page 2

Electrolux Major Appliances, N.A. - icon

Page 2 highlights

Gas Drop-In, Deep Sump Cooktop E30GC70FSS 13" max. cabinet depth 2 1/2" minimum distance between rear edge of cutout and nearest vertical combustible surface 30" 30" 213/4" 30" min. for unprotected cabinet 18" min. 24" min. for protected surface 4 1/4" 7" min. to nearest combustible wall 19" 27" (either side of unit) 8" min.* 19 1/8" min. 25" min. 19 3/4" max. 24" Opening to route 48" power cable & gas supply 27 1/4" min. 28 1/2" max. * Includes a 5" space beneath cooktop for connection to gas supply line 30" Gas Drop-In, Deep Sump Cooktop Specifications • Product Weight - 43 Lbs. • Voltage Rating - 120V / 60 Hz / 15 Amps • Connected Load (kW Rating) @ 120 Volts = 0.001 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 0.008 Amps • Always consult local and /or national electric and gas codes. • Recommended location for grounded 120V outlet is on rear wall in an 8" wide by 10" high area, positioned 22" above floor surface and 12" to right side of cooktop centerline. Access to underside of cooktop and junction box must be provided for inspection and service. • Cooktop ships with 3/4" factory regulator. • LP Gas conversion kit supplied. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 2-1/2" minimum distance between rear edge of cutout to nearest combustible surface above countertop. • Allow 7" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • Drawers cannot be installed beneath this cooktop. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved to be used over any Electrolux ICON® Single Wall Oven. (Refer to Gas Cooktop Installation Over 30" Electric Single Wall Oven Specifications page on web.) • Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved to be used in combination with an Electrolux ICON® 30" Downdraft Vent. (Refer to Drop-In Cooktop / Downdraft Vent Countertop Preparation page on web for detailed installation specifications.) Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Optional Accessories • Granite Countertop Installation Kit - (PN # 903103-9010). • Grill / Griddle - (PN # 318251603). • Simmer Plate - (PN # 318254200). • Wok Ring - (PN # 318254301). • Black Burner Knob Kit - (PN # 318242222). Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E30GC70FSS 01/09 © 2009 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2
  • 3
  • 4

Gas Drop-In, Deep Sump Cooktop
E30GC70FSS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E30GC70FSS
01/09
© 2009 Electrolux Home Products, Inc.
Printed in the U.S.A.
30" Gas Drop-In, Deep Sump Cooktop Specifications
Product Weight – 43 Lbs.
Voltage Rating –120V/60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 0.001kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @120 Volts = 0.008 Amps
Always consult local and/or national electric and gas codes.
Recommended location for grounded 120V outlet is on rear wall in an
8" wide by 10" high area, positioned 22" above floor surface and
12" to right side of cooktop centerline. Access to underside of cooktop
and junction box must be provided for inspection and service.
Cooktop ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 2-1/2" minimum distance between rear edge of cutout to nearest
combustible surface above countertop.
Allow 7" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
Drawers cannot be installed beneath this cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved to
be used over any Electrolux ICON
®
Single Wall Oven.
(Refer to Gas
Cooktop Installation Over 30" Electric Single Wall Oven Specifications
page on web.)
Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved
to be used in combination with an Electrolux ICON
®
30” Downdraft
Vent.
(Refer to Drop-In Cooktop / Downdraft Vent Countertop
Preparation page on web for detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN # 903103-9010).
Grill / Griddle – (PN # 318251603).
Simmer Plate – (PN # 318254200).
Wok Ring – (PN # 318254301).
Black Burner Knob Kit – (PN # 318242222).
8" min.*
25"min.
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
24"
Opening to route 48" power
cable & gas supply
2
1
/
2
" minimum distance between
rear edge of cutout and nearest
vertical combustible surface
7" min. to nearest
combustible wall
(either side of unit)
19
1
/
8
" min.
19
3
/
4
" max.
*Includes a 5"space beneath
cooktop for connection to
gas supply line
19"
27"
30"
21
3
/
4
"
30"
27
1
/
4
"min.
28
1
/
2
"max.
4
1
/
4
"