Electrolux E30IC80ISS Specification sheet - Page 2

Electrolux Major Appliances, N.A. - installation

Page 2 highlights

Induction Cooktop E30IC80ISS 30 3/4" 13" max. cabinet depth 1/4" 30 3/4" 211/2" 4 3/8" to service panel 19 7/8" 11/2" min. recommended distance between rear edge of cutout and nearest combustible surface above countertop Approximate location of junction box 12" 28 7/8" 10" 4 1/2" 30" min. for unprotected cabinet 24" min. for protected surface 3" 18" min. 7 1/2" min. to nearest combustible wall (either side of unit) 20 3/8" min. 25" min. 20 1/2" max. 24" 2 1/2" min. from edge of cutout to front edge of countertop 4" x 8" opening to route armored cable 29 5/8" min. 29 3/4" max. Side View Countertop Countertop Cooktop 3" Front 1/4" 4 3/8" Rear 7" 11" Service panel 30" Induction Cooktop Specifications • Product Weight - 44 Lbs. • Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz, fused on both sides of line with ground. • Connected Load (kW Rating) @ 240 / 208 Volts = 7.7 / 6.7 kW • Amps @ 240 / 208 Volts = 32.0 / 32.0 Amps • Recommended Circuit Breaker - 40 Amps • Always consult local and national electric codes. • Allow 2" space below armored cable opening to clear electrical cable and allow space for installation of junction box on wall at back of cooktop. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 1-1/2" minimum clearance between rear edge of cutout and nearest combustible surface above countertop. • Allow 7-1/2" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • It is recommended that drawers not be used beneath cooktop. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Induction Drop-In Cooktop model E30IC80ISS is approved to be used over any Electrolux ICON® Single Wall Oven. (Refer to Electric Cooktop Installation Over 30" Electric Single Wall Oven Specifications page on web.) • Induction Drop-In Cooktop model E30IC80ISS is approved to be used in combination with an Electrolux ICON® 30" Downdraft Vent. (Refer to Drop-In Cooktop / Downdraft Vent Countertop Preparation page on web for detailed installation specifications.) Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Optional Accessories • Granite Countertop Installation Kit - (PN # 903061-9010). Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E30IC80ISS 04/10 © 2010 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2
  • 3
  • 4

Induction Cooktop
E30IC80ISS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E30IC80ISS
04/10
© 2010 Electrolux Home Products, Inc.
Printed in the U.S.A.
30" Induction Cooktop Specifications
Product Weight – 44 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz,
fused on both sides of line with ground.
Connected Load (kW Rating) @ 240/208 Volts = 7.7/6.7kW
Amps @ 240/208 Volts = 32.0/32.0 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Allow 2"space below armored cable opening to clear electrical
cable and allow space for installation of junction box on wall at
back of cooktop.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 1-1/2" minimum clearance between rear edge of cutout and
nearest combustible surface above countertop.
Allow 7-1/2" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
Induction Drop-In Cooktop model E30IC80ISS is approved to be
used over any Electrolux ICON
®
Single Wall Oven.
(Refer to Electric
Cooktop Installation Over 30" Electric Single Wall Oven Specifications
page on web.)
Induction Drop-In Cooktop model E30IC80ISS is approved to be
used in combination with an Electrolux ICON
®
30" Downdraft Vent.
(Refer to Drop-In Cooktop / Downdraft Vent Countertop Preparation
page on web for detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN# 903061-9010).
4
1
/
2
"
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
24"
1
1
/
2
" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
10"
12"
Approximate location
of junction box
2
1
/
2
" min. from edge of cutout
to front edge of countertop
4"x 8" opening
to route armored cable
25"min.
20
3
/
8
" min.
20
1
/
2
" max.
29
5
/
8
"min.
29
3
/
4
"max.
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
30
3
/
4
"
1
/
4
"
21
1
/
2
"
3"
28
7
/
8
"
30
3
/
4
"
19
7
/
8
"
4
3
/
8
" to
service
panel
Countertop
4
3
/
8
"
7"
11"
Front
Rear
Side View
1
/
4
"
Service panel
Cooktop
Countertop
3"