16 Installation MAKING THE ELECTRICAL CONNECTION ! WARNING • Ensure that the power supply is disconnected before proceeding. • Verify that the power supply matches the ratings found on the appliance data plate before proceeding. • The complete appliance must be properly grounded at all times when electrical power is applied. • Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. • If aluminum house supply wiring is used, splice the appliance copper wires to the aluminum house wiring with special connectors designed and agency-certified for this purpose. Follow the connector manufacturer's recommended procedure carefully. Improper connection can result in a fire hazard. • Failure to complete electrical connections properly may result in a damaged or nonfunctional system. Follow the wiring diagrams carefully to ensure a proper installation. Figure 13 L1 BLK N1 WHT Gnd GRN 120VAC, 60Hz, 15A Supply power from dedicated circuit breaker Hood Wiring Diagram Electrical power source wiring can be connected through the top or back of the hood. Access the wiring inside the hood canopy in the area to the right side of the power ventilator. Connect the pre-wired 12" long black, white and green wires to the corresponding black, white and ground (green) wire from the power source wiring. Use wire nut connectors to secure the connections.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

16
Installation
MAKING THE ELECTRICAL CONNECTION
Electrical power source wiring can be
connected through the top or back of the
hood. Access the wiring inside the hood
canopy in the area to the right side of the
power ventilator.
Connect the pre-wired 12” long black, white
and green wires to the corresponding
black, white and ground (green) wire from
the power source wiring. Use wire nut
connectors to secure the connections.
!
WARNING
WARNING
WARNING
WARNING
WARNING
Ensure that the power supply is disconnected before proceeding.
Verify that the power supply matches the ratings found on the appliance data
plate before proceeding.
The complete appliance must be properly grounded at all times when electrical
power is applied.
Do not ground the appliance with the neutral (white) house supply wire. A
separate ground wire must be utilized.
If aluminum house supply wiring is used, splice the appliance copper wires to the
aluminum house wiring with special connectors designed and agency-certified
for this purpose. Follow the connector manufacturer’s recommended procedure
carefully. Improper connection can result in a fire hazard.
Failure to complete electrical connections properly may result in a damaged or
nonfunctional system. Follow the wiring diagrams carefully to ensure a proper
installation.
Figure 13
Hood Wiring Diagram
L1
N1
Gnd
d
GRN
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
BLK