Making The Electrical Connection
View all Electrolux E368WV60ES manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
16 Installation MAKING THE ELECTRICAL CONNECTION ! WARNING • Ensure that the power supply is disconnected before proceeding. • Verify that the power supply matches the ratings found on the appliance data plate before proceeding. • The complete appliance must be properly grounded at all times when electrical power is applied. • Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. • If aluminum house supply wiring is used, splice the appliance copper wires to the aluminum house wiring with special connectors designed and agency-certified for this purpose. Follow the connector manufacturer's recommended procedure carefully. Improper connection can result in a fire hazard. • Failure to complete electrical connections properly may result in a damaged or nonfunctional system. Follow the wiring diagrams carefully to ensure a proper installation. Figure 13 L1 BLK N1 WHT Gnd GRN 120VAC, 60Hz, 15A Supply power from dedicated circuit breaker Hood Wiring Diagram Electrical power source wiring can be connected through the top or back of the hood. Access the wiring inside the hood canopy in the area to the right side of the power ventilator. Connect the pre-wired 12" long black, white and green wires to the corresponding black, white and ground (green) wire from the power source wiring. Use wire nut connectors to secure the connections.