EleGcatrsoSlluidxe-IInCCOoNokPtorpofessional E36GC76PRS professional series 13" 2" max. cabinet depth 36" min. 35 7/8" 30" min. for unprotected cabinet 18" min. 24" min. with 25" protected bottomsurface Optional 9" stainless steel backguard (attaches to wall) 2" min. recommended distance between rear edge of cutout and nearest combustible surface above countertop 3515/16" ** 3" 2" 2" dia. opening to route 2 1/2" power cable 22" 35 1/8" 11/8" 24" max. 1" countertop overhang 4" x 4" opening to route gas supply 7 3/4" **Applies only in case of countertop backwall 9" min. to nearest combustible wall (either side of unit) 7 1/2" 7 1/4" 35 3/16" * 3515/16" * *Both cutout dimensions are critical to proper cooktop installation. Due to variations in countertop materials it is recommended to undercut finished dimension 3515/16" and adjust upon installation of cooktop. 36" Gas Slide-In Cooktop Specifications • Product Weight - 115 Lbs. • Voltage Rating - 120V / 60 Hz • Connected Load (kW Rating) @ 120 Volts = 0.12 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 0.008 A • Always consult local and national electric and gas codes. • Cooktop ships with 3/4" factory regulator. • LP Gas conversion kit supplied. • Plan installation to have electrical connection, gas shutoff valve, and pressure regulator accessible from front of cabinet. Locate 120V grounded outlet in a 4"W x 5"H area on rear wall, 16" above floor, aligned center with cooktop. • Cabinet and/or countertop must completely enclose recessed portion of cooktop. Respect cutout dimensions and clearances and ensure that all contact surfaces are solid and level. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No.28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 2" minimum clearance between rear edge of cooktop and nearest combustible surface above countertop. If required clearance can not be maintained, then optional stainless steel backguard or noncombustible backguard material must be used - otherwise installation will require custom cabinet and countertop dimensions. • Allow 9" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • It is recommended that drawers not be used beneath cooktop. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 7" beyond bottom of cabinets. • Gas Slide-In Cooktop model E36GC76PPS is NOT approved to be used over any Electrolux ICON® Single Wall Oven. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Optional Accessories • When replacing an existing cooktop with countertop cutout deeper than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler Kit - (PN# 903051-9010). • 9" Stainless Steel Backguard - (PN# 903048-9010). Electrolux Major Appliances, N.A. USA • 10200 David Taylor Drive • Charlotte, NC 28262­­• 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E36GC76PRS 03/16 © 2016 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice.

  • 1
  • 2
  • 3

High standards of quality at Electrolux Home Products, Inc.
mean we are constantly working to improve our products.
We reserve the right to change specifications or
discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
• 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) •
electroluxicon.com
CANADA
• 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 •
electroluxicon.ca
36" Gas Slide-In Cooktop Specifications
Product Weight – 115 Lbs.
Voltage Rating – 120V / 60 Hz
Connected Load (kW Rating) @ 120 Volts = 0.12 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @ 120 Volts = 0.008 A
Always consult local and national electric and gas codes.
Cooktop ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Plan installation to have electrical connection, gas shutoff valve, and
pressure regulator accessible from front of cabinet. Locate 120V
grounded outlet in a 4"W x 5"H area on rear wall, 16" above floor,
aligned center with cooktop.
Cabinet and/or countertop must completely enclose recessed portion
of cooktop. Respect cutout dimensions and clearances and ensure that
all contact surfaces are solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No.28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
Allow 2" minimum clearance between rear edge of cooktop and nearest
combustible surface above countertop. If required clearance can not be
maintained, then optional stainless steel backguard or noncombustible
backguard material must be used — otherwise installation will require
custom cabinet and countertop dimensions.
Allow 9" minimum clearance from edge of cooktop to nearest combustible
wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 7" beyond bottom
of cabinets.
Gas Slide-In Cooktop model E36GC76PPS is NOT approved to be used
over any Electrolux ICON
®
Single Wall Oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
When replacing an existing cooktop with countertop cutout deeper
than 7-1/4" and less than 8-1/2", order free Depth Adjustment
Filler Kit – (PN# 903051-9010).
9" Stainless Steel Backguard – (PN# 903048-9010).
25"
35
7
/
8
"
2"
7
3
/
4
"
Optional 9" stainless
steel backguard
(attaches to wall)
36" min.
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. with
protected
bottomsurface
**Applies only in case of
countertop backwall
35
15
/
16
"
*
*
1
1
/
8
"
max.
7
1
/
2
"
35
3
/
16
"
*
35
15
/
16
"
*
1" countertop
overhang
*Both cutout dimensions are
critical to proper cooktop installation.
Due to variations in countertop materials it is
recommended to undercut finished dimension
35
15
/
16
" and adjust upon installation of cooktop.
24"
2" min. recommended distance between
rear edge of cutout and nearest combustible
surface above countertop
2"
3"
2" dia.
opening to route
power cable
2
1
/
2
"
9" min. to nearest
combustible wall
(either side of unit)
4" x 4" opening to
route gas supply
22"
35
1
/
8
"
7
1
/
4
"
E36GC76PRS 03/16
© 2016 Electrolux Home Products, Inc.
Gas Slide-In Cooktop
E36GC76PRS
professional series