Electrolux E42BS75EPS Specification sheet - Page 2

Door-Swing Clearances, Cutout, Dimensions - e42bs75ep refrigerator

Page 2 highlights

Built-In Refrigerator E42BS75EPS professional series Power cord location (right top rear) 41" case width 25 3/8" * 83 3/4" at rear 84" from floor to top frame Cutout Dimensions (A) Finished opening: A 831/2" min. 841/2" max. (B) 411/2" (C) 24" B 3" C Water 31/2" supply 5" 7"x 7" electrical area 74" from floor to bottom of electrical area 31/2" 26 7/8" (including handle) 42" frame to frame Water line inlet location (left bottom front) * Shipping height. (Front height may be adjusted from 83-1/2" to 84-1/2" by adjusting leveling legs a max. of 1".) Door-Swing Clearances Refrigerator equipped with 2-position door stop. Factory set to 130°, adjustable to 90° if clearance to adjacent cabinets or wall is restricted. 123/16" 41" 130° 16" Door Swing Notes: A 4" min. door clearance is required when using 90° door stop position. Drawer access is maintained, but removal is restricted. To determine door swing interaction with adjacent cabinets and countertops refer to Product Installation Guide on web at electroluxicon.com. 41" 90° Door Swing 23 7/8" behind frame 24" 4" min. to wall 42" Built-In Refrigerator Specifications • Product Weight - 610 Lbs. • Voltage Rating - 120V / 60 Hz / 15 or 20 Amps • Connected Load (kW Rating) @ 120 Volts = 0.65 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 5.4 Amps • Always consult local and /or national electric & plumbing codes. • Cutout must be prepared with electrical and water supply located as shown. When possible, recess copper water line and electrical outlet. • Water line can enter opening through floor or rear wall. Copper tubing recommended between cold water line and water connection location. Water line tubing recommended is 48" minimum length by 1/4" diameter. Installation of easily accessible shutoff valve in water line required. • Optimum door swing factory set for 130°. When installing next to wall where handle may make contact, allow 4" minimum clearance for 90° door swing. At 90° door stop position, drawer access will be maintained but removal will be restricted. • Refrigerator must be placed on level surface of hard material, same height as flooring. Surface must support approximately 1500 Lbs. when fully loaded. Unit equipped with 4-point leveling. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E42BS75EPS 01/09 © 2009 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2

Built-In Refrigerator
E42BS75EPS
professional series
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E42BS75EPS
01/09
© 2009 Electrolux Home Products, Inc.
Printed in the U.S.A.
42" Built-In Refrigerator Specifications
Product Weight – 610 Lbs.
Voltage Rating –120V/60Hz/15 or 20 Amps
Connected Load (kW Rating) @120 Volts = 0.65kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @120 Volts = 5.4 Amps
Always consult local and/or national electric & plumbing codes.
Cutout must be prepared with electrical and water supply located as
shown. When possible, recess copper water line and electrical outlet.
Water line can enter opening through floor or rear wall. Copper tubing
recommended between cold water line and water connection location.
Water line tubing recommended is 48" minimum length by 1/4" diameter.
Installation of easily accessible shutoff valve in water line required.
Optimum door swing factory set for 130°. When installing next to wall
where handle may make contact, allow 4" minimum clearance for 90°
door swing. At 90° door stop position, drawer access will be maintained
but removal will be restricted.
Refrigerator must be placed on level surface of hard material, same
height as flooring. Surface must support approximately 1500 Lbs. when
fully loaded. Unit equipped with 4-point leveling.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Door-Swing Clearances
Refrigerator equipped with 2-position door
stop. Factory set to 130
°
, adjustable to
90
°
if clearance to adjacent cabinets or
wall is restricted.
130
°
Door Swing
12
3
/
16
"
41"
16"
24"
23
7
/
8
"
behind
frame
41"
90
°
Door Swing
4"min. to wall
Notes:
A 4" min. door clearance is required when
using 90
°
door stop position. Drawer access
is maintained, but removal is restricted.
To determine door swing interaction with
adjacent cabinets and countertops refer to
Product Installation Guide on web at
electroluxicon.com
.
B
7"x 7"
electrical
area
74"from
floor to
bottom of
electrical
area
Water
supply
A
5"
C
3"
3
1
/
2
"
3
1
/
2
"
Cutout
Dimensions
(A) Finished
opening:
83
1
/
2
"min.
84
1
/
2
"max.
(B) 41
1
/
2
"
(C) 24"
26
7
/
8
"
(including
handle)
*Shipping height. (Front height may be adjusted from 83-1/2"
to 84-1/2" by adjusting leveling legs a max. of 1".)
Water line inlet location
(left bottom front)
42"
frame to frame
*83
3
/
4
"
at rear
41"case width
Power cord location (right top rear)
25
3
/
8
"
84"
from
floor
to
top
frame