Electrolux EFDC317TIW Wiring Diagram English - Page 1

Electrolux EFDC317TIW Manual

Page 1 highlights

Dryer Tech Data Sheet This information is intended for Qualified Technicians Only. TABLE OF CONTENTS Dryer Tech Data Sheet 1 Diagnostic Mode Tests/Demo Mode 2 Dryer Error Codes 3 Notes 10 Wiring Diagrams 11 1 Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described below: This symbol alerts you to situations that may WARNING cause serious body harm, death or property damage. CAUTION This symbol alerts you to situations that may cause bodily injury or property damage. CAUTION Unless otherwise directed, disconnect electrical current before servicing. Push Button Cycle Select Dryer User Interface 1 2 3 Rotary Dial Cycle Select Dryer User Interface 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 power 2 cycle status display 3 cycle selector 4 temperature 5 dryness level 6 drying time 7 options 8 set 9 cancel 10 start/pause Entering Diagnostic Mode: 1. Press power and look for console light up. 2. Rotate cycle selector ring (on some models) or repeatedly press cycle button (on other models) to set cycle to normal. 3. Press the start button. 4. Power off machine by pressing the power button. 5. Power on machine by pressing the power button again. 6. Within 10 seconds, simultaneously hold temp + set buttons together for 3 seconds. 7. Diagnostic Mode is active when LED's start blinking in sequence. This is the pre-test position " " which tests the lights and buttons. 8. Press the start button. Scrolling through Diagnostic Mode tests: Tests are selected by using the same method used to select cycles. Models with the cycle selection button uses the cycles button to move forward, holding a little longer for the test " " (cycle lights) to " " transition and press the temp key to go back to the previous test. Models with the rotary cycle selector use the rotary selector ring to go forward and back. Test numbers are briefly displayed when each test is selected. The test numbers also correspond to the selector LEDs numbered from 1 at the top going down. Exiting Diagnostic Mode: Hold the power key for 3 seconds, when not in " Buttons, or unplug the unit. " test step Lights/ USA 1-877-435-3287 www.electroluxappliances.com A07020402 (1901) Canada 1-800-265-8352

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

1
Canada 1-800-265-8352
1
power
2
cycle status display
3
cycle selector
4
temperature
5
dryness level
6
drying time
7
options
8
set
9
cancel
10
start/pause
2
7
1
6
3
8
5
4
9
10
Push Button Cycle Select Dryer User Interface
Rotary Dial Cycle Select Dryer User Interface
2
7
1
6
3
9
8
5
4
10
A07020402
(1901)
USA 1-877-435-3287
This information is intended for Qualified Technicians Only.
TABLE OF CONTENTS
Entering Diagnostic Mode:
1.
Press
power
and look for console light up.
2.
Rotate cycle selector ring (on some models) or repeatedly press
cycle button (on other models) to set cycle to
normal
.
3.
Press the
start
button.
4.
Power off machine by pressing the
power
button.
5.
Power on machine by pressing the
power
button again.
6.
Within
10
seconds, simultaneously hold
temp + set
buttons
together for
3
seconds.
7.
Diagnostic Mode
is active when LED’s start blinking in sequence.
This is the pre-test position “
which tests the lights and buttons.
8.
Press the
start
button.
Safety items throughout this manual are labeled with a
WARNING
or
CAUTION
based on the risk type as described below:
This symbol alerts you to situations that may
cause bodily injury or property damage.
This symbol alerts you to situations that may
cause serious body harm, death or property
damage.
Dryer Tech Data Sheet
Scrolling through Diagnostic Mode tests:
Tests are selected by using the same method used to select cycles.
Models with the cycle selection button uses the
cycles
button to move
forward, holding a little longer for the test “
(cycle lights) to “
transition and press the
temp
key to go back to the previous test.
Models with the rotary cycle selector use the rotary selector ring to go
forward and back.
Test numbers are briefly displayed when each test is selected. The test
numbers also correspond to the selector LEDs numbered from 1 at the
top going down.
Exiting Diagnostic Mode:
Hold the
power
key for
3
seconds, when not in “
test step Lights/
Buttons, or unplug the unit.
www.electroluxappliances.com
CAUTION
WARNING
CAUTION
Unless otherwise directed, disconnect electrical current before
servicing.
Dryer Tech Data Sheet
................................................................
1
Diagnostic Mode Tests/Demo Mode
...........................................
2
Dryer Error Codes
.......................................................................
3
Notes
.......................................................................................
10
Wiring Diagrams
.......................................................................
11