Electrolux EFMG627UTT Product Specifications Sheet English - Page 3

Built-In Installations

Page 3 highlights

Front Load Gas Dryers GEFMAG6S27UFTRT /EE OIWFlNeMTcLtGrO4oA2lDu7xDUR_YEEFRMG527U_EFMG627U (steam) Front 27" 3/4" hose clearance required 31 1/2" Left 50 5/8" Rear 2 1/4" Wall Water inlet 2 1/2" 38" (75 3/4" min. for stacked units) Reversible Door Swing 8 1/2" 120V Power cord 3 3/4" 1 7/16" 15" Pedestal Drawer Installation Elevates dryer height to 53 1/4". For detailed pedestal installation, refer to instructions included with pedestal or on web. Pedestal Installation may require modified utility hookup locations. For details, refer to Product Installation Guide on web. 27" Built-In Installations 0" min. 0" min. 0" min.* 1" min. Front Vented door Side 3" 60" sq. in. min. Front 26 1/2" Side Overall depth with drawer fully extended - 421/2" 60" 15" sq. in. min. 3" *Steam dryer requires additional 3/4" hose clearance. 15 1/4" Closet Installation: If washer and dryer are installed in same closet, door(s) MUST be vented with 120 sq.in. minimum louvered opening, equally divided, located 3" from top and bottom of door. Louvered door(s) with equivalent air openings for full-length of door is acceptable. Air openings MUST remain unobstructed with door(s) installed. 3 7/16" 13 1/2" Gas supply pipe Installation Clearances: Dryer can be built in alone or with washer (side by side or stacked) in closet, recess or under counter installation with 0" minimum clearance required around sides and back of unit(s). To achieve 0" minimum rear clearance, dryer MUST be vented straight back or with quick-turn 90° elbow. Steam dryer requires additional 3/4" steam hose clearance at back of unit(s). Installation of closet door(s) requires additional 1" minimum clearance between front of unit(s) and door(s). Location of plumbing, exhaust and utility hookups MUST be considered when planning any built-in installation. For additional installation details, refer to Product Installation Guides on web. Under Counter Installation: Installation of dryer alone or side by side with washer under counter, requires custom-built countertop and/or cabinetry to accommodate unit(s) height. Stacking Units: Stacking dryer above washer requires use of optional Stacking Kit (PN# STACKIT7X) with modified utility hookup locations for dryer. For complete installation details, refer to instructions included with Stacking Kit or on web. Gas Dryer Specifications • Product Weight - 130 Lbs. / Shipping Weight - 140 Lbs. • An electrical supply with grounded three-prong receptacle is required. The power supply circuit must be installed in accordance with current edition of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances. (Do not use same circuit as washer.) • Voltage Rating - 120V / 60 Hz • Connected Load (kW Rating) @ 120 Volts = 0.835 kW • Amps @ 120V = 9A • Equipped with 120V 3-wire power supply cord, approx. 60" long. • Always consult local and national electric, gas & plumbing codes. • Can be installed alone, with or without optional 15" pedestal drawer, or stacked above matching Electrolux Washer, which requires installation of optional dryer stacking kit. (For installation details, refer to instructions included with optional pedestal or stacking kit or on web.) • Can be built in alone or with matching Electrolux Washer (side by side or stacked) in closet, recess or under counter installation with 0" minimum clearance required around sides and back of unit(s). To achieve 0" minimum rear clearance, dryer MUST be vented straight back or with quick-turn 90° elbow. Steam dryer requires additional 3/4" steam hose clearance at back of unit(s). Installation of closet door(s) requires additional 1" minimum clearance between front of unit(s) and door(s). Location of plumbing, exhaust and utility hookups MUST be considered when planning any built-in installation. • Under-counter installation requires custom-built countertop and/or cabinetry to accommodate unit(s) height. • Do NOT install in area exposed to dripping water or outdoor weather conditions, or where gasoline or other flammables, including automobiles, are kept or stored. Electrolux Major Appliances, N.A. • For garage installation, dryer MUST be located minimum 18" above floor. • Floor MUST be solid with 1" maximum slope. To ensure vibration or movement does not occur, reinforcement of floor may be necessary. Do NOT install on carpeted surface. • Dryer MUST exhaust to outside of building, NOT into any concealed space. • Dryer equipped for 4-way venting and approved for up to 125-foot-equivalent of duct length, determined by length of run and number of elbows needed. • Exhaust installation requires minimum 4"-diameter rigid or semi-rigid metal duct with approved, unobstructed vent hood having swing-out damper(s). If installing rigid metal duct (preferred), do not exceed MAXIMUM venting run length of 125 ft., allow deductions for elbows and vents. If installing semi-rigid metal duct, do not exceed MAXIMUM venting run length of 8 ft., always allow deductions for elbows and vents (Refer to Product Installation Guide on web for additional information). Do NOT use flexible plastic or metal foil duct and use shortest run possible. • Gas supply line should be 1/2" pipe and MUST have individual shutoff valve. • Leveling legs supplied to level dryer properly and reduce excessive noise and vibration. • Water inlet hose for steam setting connects to cold water supply with "Y" connector and requires 3/4" clearance between back of unit and wall. Note: F or planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions. Optional Accessories • Pedestal Drawers - Titanium (PN # EPWD257UTT), Island White (PN # EPWD257UIW). • Dryer Stacking Kit - (PN # STACKIT7X). • LP Gas Conversion Kit - (PN # PCK4200). • Drying Rack - (PN # A04840701). • Assembly Hose Kit - (PN # 5304495002). USA • 10200 David Taylor Drive • Charlotte, NC 28262­­• 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca EFMG627U 0518 © 2018 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice.

  • 1
  • 2
  • 3

High standards of quality at Electrolux Home Products, Inc.
mean we are constantly working to improve our products.
We reserve the right to change specifications or
discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
3
/
4
" hose
clearance
required
Wall
38"
(75
3
/
4
"
min.
for stacked
units)
27"
Front
Rear
15"
Pedestal Drawer
Installation
Elevates dryer height to 53
1
/
4
"
.
For detailed pedestal installation,
refer to instructions included
with pedestal or on web.
Pedestal Installation may require
modified utility hookup locations.
For details, refer to Product
Installation Guide on web.
Installation Clearances:
Dryer can be built in alone or with washer
(side by side or stacked)
in closet, recess or
under counter installation with 0"
minimum
clearance required around sides and back of
unit(s).
To achieve 0"
minimum rear clearance,
dryer MUST be vented straight back or with
quick-turn 90
°
elbow. Steam dryer requires
additional 3/4" steam hose clearance at back of
unit(s). Installation of closet door(s) requires
additional 1"
minimum clearance between front
of unit(s) and door(s). Location of plumbing,
exhaust and utility hookups MUST be considered
when planning any built-in installation. For
additional installation details, refer to Product
Installation Guides on web.
Under Counter Installation:
Installation of dryer alone or side by side
with washer under counter, requires custom-built
countertop and/or cabinetry to accommodate
unit(s) height.
Stacking Units:
Stacking dryer above washer requires use of
optional Stacking Kit (PN# STACKIT7X) with
modified utility hookup locations for dryer. For
complete installation details, refer to instructions
included with Stacking Kit or on web.
Vented door
3"
3"
60"
sq.
in.
min.
60"
sq.
in.
min.
Closet Installation:
If washer and dryer are installed in same closet, door(s)
MUST be vented with 120 sq.
in. minimum louvered
opening, equally divided, located 3" from top and bottom
of door. Louvered door(s) with equivalent air openings for
full-length of door is acceptable. Air openings MUST
remain unobstructed with door(s) installed.
Built-In Installations
Side
0"min.
0"min.
0"min.*
1"min.
Front
*Steam dryer requires additional 3/4" hose clearance.
26
1
/
2
"
Overall depth with drawer
fully extended – 42
1
/
2
"
15
1
/
4
"
Side
27"
15"
Front
3
3
/
4
"
1
7
/
16
"
120V
Power cord
13
1
/
2
"
8
1
/
2
"
3
7
/
16
"
2
1
/
4
"
2
1
/
2
"
Water inlet
Gas supply pipe
Left
50
5
/
8
"
31
1
/
2
"
Reversible
Door Swing
For garage installation, dryer MUST be located minimum 18" above floor.
Floor MUST be solid with 1" maximum slope. To ensure vibration or movement
does not occur, reinforcement of floor may be necessary. Do NOT install on
carpeted surface.
Dryer MUST exhaust to outside of building, NOT into any concealed space.
Dryer equipped for 4-way venting and approved for up to 125-foot-equivalent
of duct length, determined by length of run and number of elbows needed.
Exhaust installation requires minimum 4"-diameter rigid or semi-rigid metal duct
with approved, unobstructed vent hood having swing-out damper(s). If installing
rigid metal duct (preferred), do not exceed MAXIMUM venting run length of 125 ft.,
allow deductions for elbows and vents. If installing semi-rigid metal duct, do not
exceed MAXIMUM venting run length of 8 ft., always allow deductions for elbows
and vents
(Refer to Product Installation Guide on web for additional information)
.
Do NOT use flexible plastic or metal foil duct and use shortest run possible.
Gas supply line should be 1/2" pipe and MUST have individual shutoff valve.
Leveling legs supplied to level dryer properly and reduce excessive noise and
vibration.
Water inlet hose for steam setting connects to cold water supply with “Y”
connector and requires 3/4" clearance between back of unit and wall.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Pedestal Drawers – Titanium (PN #
EPWD257U
TT), Island White (PN #
EPWD257U
IW).
Dryer Stacking Kit – (PN # STACKIT7X).
LP Gas Conversion Kit – (PN # PCK4200).
Drying Rack – (PN # A04840701).
Assembly Hose Kit – (PN # 5304495002).
Gas Dryer Specifications
Product Weight – 130 Lbs. / Shipping Weight – 140 Lbs.
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current edition
of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.
(Do not use same circuit as washer.)
Voltage Rating – 120V / 60 Hz
Connected Load (kW Rating) @ 120 Volts = 0.835 kW
Amps @ 120V = 9A
Equipped with 120V 3-wire power supply cord, approx. 60" long.
Always consult local and national electric, gas & plumbing codes.
Can be installed alone, with or without optional 15" pedestal drawer, or
stacked above matching Electrolux Washer, which requires installation of
optional dryer stacking kit.
(For installation details, refer to instructions
included with optional pedestal or stacking kit or on web.)
Can be built in alone or with matching Electrolux Washer
(side by side or stacked)
in closet, recess or under counter installation with 0" minimum clearance
required around sides and back of unit(s). To achieve 0" minimum rear clearance,
dryer MUST be vented straight back or with quick-turn 90° elbow. Steam dryer
requires additional 3/4" steam hose clearance at back of unit(s). Installation
of closet door(s) requires additional 1" minimum clearance between front of
unit(s) and door(s). Location of plumbing, exhaust and utility hookups MUST be
considered when planning any built-in installation.
Under-counter installation requires custom-built countertop and/or cabinetry
to accommodate unit(s) height.
Do NOT install in area exposed to dripping water or outdoor weather
conditions, or where gasoline or other flammables, including automobiles,
are kept or stored.
EFMG627U 0518
© 2018 Electrolux Home Products, Inc.
GAS FRONT LOAD DRYER
EFMG627U TT / IW