Electrolux EI23BC35KB Wiring Diagram (English Español França - Page 1
Electrolux EI23BC35KB Manual
![]() |
View all Electrolux EI23BC35KB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor Operating Time 65°F (18°C) Ambient 90 to 100% 90°F (32°C) Ambient 100% Freezer Temperature Refrigerator Temperature Low Side Pressure High Side Pressure (last 1/3 cycle) Wattage (last 1/3 cycle) Amps (running) -5° to 2°F (-20° to -17°C) 34° to 39°F (1° to 4°C) -2 to 6 psig ( -14 to 41 kPa) 85 to 105 psig (586 to 724 kPa) 30 to 50 .4 to .8 -1° to 3°F (-18° to -16°C) 34° to 39°F (1° to 4°C) -2 to 6 psig (-14 to 41 kPa) 120 to 135 psig (827 to 931 kPa) 50 to 70 .7 to .9 Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS Cabinet Size Thermostat Cut-in Cut-out Heater Watts 26' & 28' SD, 23' CD 25°F (-4°C) 47°F (8°C) 500 Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR Ohms 26.5 Watts 3.1 RPM 1100 CW Opposite Shaft Amps 0.03 Running FREEZER ICE MAKER SPECIFICATIONS Electrical 115 vac (127 vac max) Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) Heater Voltage 115 vac FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green / Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral LINE POWER NEUTRAL ICE MAKER LT. BLUE ICE MAKER BLK BRN P-3 THERMAL CUT-OUT WATER VALVE ICE MAKER BLK RED MOTOR RED HOLD SWITCH NO LT. BLUE RED C NC THERMOSTAT P-4 NO BLK BLU NC C MOLD HEATER 165 WATTS SHUTOFF NO SWITCH GRN / YEL P-1 MOLD MOUNTING PLATE ICE MAKER NC C WATER FILL SWITCH YELLOW P-2 CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. SERVICE DATA SHEET 242199100 ICE & WATER - AUTOMATIC DEFROST BOTTOM FREEZER - R134a IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Error Codes Special Modes Display FZ FF Interpretation Mode Display FZ FF Activate/Deactivate (press for up to 10 sec. simultaneously) -- OP Open FF Thermistor Manual Defrost d F FF UP and FF DOWN / same to deactivate OP -- Open FZ Thermistor Display / Showroom 77 77 FZ UP and FF DOWN / Power-on-Reset (POR) -- SH Shorted FF Thermistor Sabbath Sb Sb FZ DOWN and FF UP / same to deactivate Shorted FZ Thermistor System Diagnostic No FF or FZ display, FZ UP and FZ DOWN / FF UP to deactivate SH -- all UI LEDs on. UI to Main Control FFIM Diagnostic SY CF Board communication failure; on start up Numerical display of first test FZ UP and FF UP together to activate / press and hold FF UP to deactivate UI Main Control Board Notes: SY CE communication error; • Always check for pin back-outs, pinched or damaged wires before replacing components. after a period in operation • Determine whether failure is caused by the component, main control board or wiring. Contact SY EF Evaporator Fan Failure TID before replacing main control board. • Refer to Service Manual for additional information. Fresh Food Ice Maker Diagnostic Mode Activate: Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously. Press FF UP or FF DOWN to move forward or backward through tests. Deactivate: Press FF UP for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity. NOTE: Silence alarm. Test To activate test Passing Result 52C Ice Maker Thermistor Activates FZ display shows temperature sensed by Ice Maker Thermistor. automatically "OP" if open; "SH" if short 55C Water Valve Press power Remove ice tray to collect water into a measuring container to measure wa- on-off ter fill. If collecting water into ice tray, first perform test 63C to empty ice tray. 57C Evaporator Fan (FFIM) Press power "On" on FZ display when fan activated, "OFF" when deactivated. on-off Ice Level Sensor 58C Activates automatically Remove ice bucket. Allow bail arm to drop freely. Pass if no alarm when tray returns to "home" position. Hold bail arm up. Pass if alarm sounds when tray returns to "home" position. This test runs continuously until another test is selected. 63C Twist Tray Press power Remove ice bucket. on-off FZ display shows "1" and "GOOD". Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows: → Check at the connector from the power cord harness into the inverter board, located in the machine compartment. (PUR and WHT wires) Is Inverter Board receiving 115 VAC from power supply? → Check at Inverter Board on Compressor yes (BLK and RED wires) Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board? → Remove inverter box from the compressor and check resistance yes across compressor winding pairs as shown. Is resistance across all winding pairs equal? no no no → Check connections from Inverter Board to Compressor yes Are connections from Inverter Board to Compressor intact? no • Check voltage supply. • Check and repair power cord harness wiring and connections. → Check at Main Control Board (BLK/WHT and RED/BLK wires) no Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board? yes Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. Replace Compressor and Inverter Board. Replace Main Control Board. Identify and repair damaged wires or poor connections between Inverter Board and Compressor. yes VCC Resistance Check Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. Replace Inverter Board FREEZER ICE MAKER INFORMATION (Where Applicable) Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Water Fill Adjustment Motor Gear Mounting Plate Screw N TUR Mounting Plate Screws Timing Gear System Diagnostic Mode Activate: Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously. Press FF UP to advance through tests. Deactivate: Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. • Tests marked with "*" may not be applicable to this unit and will not be displayed in System Diagnostic Mode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. Test To activate test: Passing result -- First Screen -- All LED lights on UI illuminated -- Second Screen -- All segments on UI temperature displays illuminated -- Third Screen -- Blank UI display, no lights illuminated, no shadowing; "-" and "+" blinking on FF display side to show location. 28 Dispenser Paddle Press disp. paddle "on" on UI when depressed; "off" when released 1* Standard Compressor Press power on-off Compressor running when "on"; stopped when "off" 2 Defrost Heater Press power on-off Defrost limit switch must be closed; verify "CL" in test 26. Feel for heat from defrost heater when "on". If "OP" in test 26, heater will not activate. 3 FF Light Press power on-off With FF door open, FF lights on when "on"; off when "off" 8 Water Valve (Dispenser) Press power on-off FF door must be closed. Be prepared to collect water at dispenser. Water dispenses when "on"; stops when "off" 9 FZ Light Press power on-off With FZ door open, FZ lights on when "on", off when "off" 10 Auger Motor Press power on-off FF door must be closed. Motor running when "on"; motor stopped when "off" 11 Cube/Crush Solenoid Press power on-off FF door must be closed. Do not leave solenoid in activated state. Solenoid activated when "on"; deactivated when "off" 41* Perfect Temp Drawer Press power on-off (PTD) PTD UI illuminated when "on", off when "off" 12* VCC Condenser Fan Press power on-off Fan running when "on"; stopped when "off" 38* VCC Compressor Press power on-off Compressor running when "on"; stopped when "off" 15 Evaporator Fan Press power on-off Fan running for minimum of 10 sec. when "LO" or "HI"; stopped when "off". Feedback failure if fan starts but runs less than 10 sec. Listen for speed change from "LO" to "HI". 22 Damper Press power on-off With inspection mirror, observe damper open when "OP"; closed when "CL" 23 FF Door Open/close FF door "CL" on UI when door closed; "OP" when open 24 FZ Door Open/close FZ door "CL" on UI when door closed; "OP" when open 26 Defrost Limit Switch Activates automatically "CL" on UI when closed; "OP" when open 36 Ice Chute Door Depress ice chute door "OP" on UI when manually opened; "CL" when closed. Or, using "power onor press power on-off off", "OP" on UI when solenoid activated, "CL" when deactivated 29 FF Thermistor Midlevel Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at mid-level FF thermistor location. "OP-" if open; "SH-" if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location. "OP" if open; "SH" if short 33 Ambient Thermistor Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of @ Main Board temperature measured with gauge at main board location. "OP" if open; "SH" if short 35* FF Thermistor Upper-Level Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F of temperature measured with gauge at upper-level FF thermistor location. "OP¯" if open; "SH¯" if short 34* Ambient Thermistor Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera- @ UI ture measured with gauge at UI location. "OP" if open; "SH" if short 0- Firmware Parameters Press power on-off Displays digit sequence; record 2- Main Board Firmware Press power on-off Displays digit sequence; record 4- UI Firmware Press power on-off Displays digit sequence; record IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
![](/manual_guide/products/electrolux-ei23bc35ks-wiring-diagram-english-espa241ol-fran231ais-facad3d/1.png)