Page 35 highlights
Solutions to Common Problems 35 Dispenser (Ice & Water--continued) Concern Potential Cause Ice dispenser is jammed. • Ice has melted and frozen around auger due to infrequent use, temperature fluctuations, and/or power outages. • Ice cubes are frozen together. • Ice cubes are smaller than normal. Dispenser will not dispense water. • Dispenser lock out is engaged. • Water filter not seated properly. • Water filter is clogged. • Household water line valve is not open. Water has an odd taste and/or odor. Water pressure is extremely low. • Water has not been dispensed for an extended period of time. • Unit not properly connected to cold water line. • Cut-off and cut-on pressures are too low (well systems only). • Reverse osmosis system is in regenerative phase. Common Solution • Remove ice bin, thaw, and empty the contents. Clean bin, wipe dry, and replace in proper position. When new ice is made, dispenser should operate. • Use the dispenser often so that cubes do not freeze together. • The ice & water filter cartridge could be clogged. Replace the filter cartridge. Dispensing system operates best at 30100 psi water pressure. Well water pressures should fall within this range. • Press and hold control lock for three (3) seconds. • Remove and reinstall the water filter. Be sure to push the filter firmly so that you hear it lock solidly into position. • Replace filter cartridge. Be sure to remove protective caps and push the filter firmly so that you hear it lock solidly into position. • Open household water line valve. See Problem section, Ice Maker Is Not Making Ice. • Draw and discard 10-12 glasses of water to freshen the supply and completely rinse out the tank. • Connect unit to cold water line that supplies water to the kitchen faucet. • Have someone turn up the cut-off and cut-on pressure on the water pump system (well systems only). • It is normal for a reverse osmosis system to be below 20 psi during the regenerative phase. Light Is Not On Concern Potential Cause Light is not on. • Light bulb is burned out or LED light is damaged. • No electric current is reaching refrigerator. • Control system has disabled lights because one or both doors were left open too long. Common Solution • See Replacing Light Bulbs or LED lights in Care and Cleaning section. • See "Problem" section, "Running Your Refrigerator". • Close and reopen door(s) to enable lights. Odors In Refrigerator Concern Potential Cause Interior is dirty. Odors • Interior needs to be cleaned. • Food with strong odors is stored in refrigerator. Common Solution • See Care & Cleaning Tips. • Cover food tightly. Turn on air filtration system. Air filter may need to be changed more frequently if foods with strong odors are routinely stored in refrigerator. Opening/Closing Of Doors/Drawers Concern Potential Cause Door(s) will not close. • Refrigerator is not level. It rocks on the floor when moved slightly. Drawers are • Food is touching shelf on top of drawer. difficult to move. • Drawer is overloaded Common Solution • Ensure floor is level and solid, and can adequately support the refrigerator. Contact a carpenter to correct a sagging or sloping floor. • Keep less food in drawer. • Remove or redistribute food.