Electrolux EI36DD10KS Product Specifications Sheet (English) - Page 2

Electrolux Major Appliances, N.A. - home products

Page 2 highlights

Downdraft Vent EI36DD10K S Downdraft Vent Specifications • Downdraft Vent requires installation with Blower Motor System Kit - 1600 CFM Remote option or 600 CFM Integrated option (kit ordered separately). Vent ships with transition duct pre-attached to chassis housing for Remote Blower Motor installation and is removable for Integrated Blower Motor installation. For Blower Motor System planning information, refer to specific kit's specifications page; for complete installation details and specifications, refer to specific Product Installation Guides on web. • Voltage Rating - 120V / 60 Hz / 15 Amps • Connected Load (kW Rating) and Amps @ 120 Volts - Refer to specific Blower Motor System Kit specification page. • Do not use same circuit as cooktop. • Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale. • Locate grounded electrical outlet for 28"- long power cord within reachable distance. When installing vent in 36"- wide cabinet, outlet cannot be located on back wall of cabinet, but can be wall-mounted with access hole in cabinet. • Downdraft Vent designed for installation with cooktop in island, peninsula or conventional installation. (Cutout template provided, packed with vent.) • To ensure proper installation with cooktop, refer to model-specific cooktop installation guide on web for dimensions, countertop cutout dimensions and cabinet requirements; oversized cabinets recommended for ease of installation. Due to varying cooktop depths, tight fit is possible between cooktop and vent, depending on overall depth of countertop. • Pre-formed countertops with raised lip and /or backsplash may not allow enough flat area for proper installation. Minimum 2-5/16" of flat countertop required behind cooktop and 2-1/16" necessary between back edge of cooktop and inside of cabinet back. • To ensure adequate clearance for air vent when raised /lowered, 1/8" gap needed between back edge of cooktop and front of downdraft top trim. • Vent exhaust air outside only. • Exhaust Duct Required - Refer to specific Blower Motor System Kit specifications page. • Three blower discharge direction options available. Pre-positioned with discharge facing down; left or right discharge requires 90-degree transition duct rotation. Transition duct can also be mounted to back of chassis housing with minimum 3-3/4" clearance to back of cabinet wall. • Consider ductwork location before cutting hole in cabinet. • For maximum efficiency, use shortest and straightest duct run possible. System operates most efficiently with up to 60 equivalent feet of duct; Downdraft Vent operates properly with ductwork up to 100 equivalent feet. (Refer to Calculating Duct Length Table in Product Installation Guide.) • Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required. • Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. Cold weather installations should have additional backdraft damper installed. • High level of airflow may affect gas flame on some gas cooktop models. Blower Motor System Options • 1600 CFM Remote Blower Motor System Kit - (PN # EI16DDPRKS). • 600 CFM Integrated Blower Motor System Kit - (PN # EI06DDPIKS). Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions. Electrolux Major Appliances, N.A. USA • 10200 David Taylor Drive • Charlotte, NC 28262­­• 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca EI36DD10K 07/12 © 2012 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice.

  • 1
  • 2
  • 3
  • 4

Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
EI36DD10K
07/12
© 2012 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Downdraft Vent
EI36DD10K S
Downdraft Vent Specifications
Downdraft Vent requires installation with Blower Motor System Kit –
1600 CFM Remote option or 600 CFM Integrated option (kit ordered
separately). Vent ships with transition duct pre-attached to chassis housing
for Remote Blower Motor installation and is removable for Integrated Blower
Motor installation. For Blower Motor System planning information, refer
to specific kit’s specifications page; for complete installation details and
specifications, refer to specific Product Installation Guides on web.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) and Amps @ 120 Volts – Refer to specific
Blower Motor System Kit specification page.
Do not use same circuit as cooktop.
Always consult local and national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
Locate grounded electrical outlet for 28"- long power cord within reachable
distance. When installing vent in 36"- wide cabinet, outlet cannot be
located on back wall of cabinet, but can be wall-mounted with access
hole in cabinet.
Downdraft Vent designed for installation with cooktop in island, peninsula
or conventional installation.
(Cutout template provided, packed with vent.)
To ensure proper installation with cooktop, refer to model-specific
cooktop installation guide on web for dimensions, countertop cutout
dimensions and cabinet requirements; oversized cabinets recommended
for ease of installation. Due to varying cooktop depths, tight fit is possible
between cooktop and vent, depending on overall depth of countertop.
Pre-formed countertops with raised lip and /or backsplash may not
allow enough flat area for proper installation. Minimum 2-5/16" of flat
countertop required behind cooktop and 2-1/16" necessary between
back edge of cooktop and inside of cabinet back.
To ensure adequate clearance for air vent when raised /lowered, 1/8" gap
needed between back edge of cooktop and front of downdraft top trim.
Vent exhaust air outside only.
Exhaust Duct Required – Refer to specific Blower Motor System Kit
specifications page.
Three blower discharge direction options available. Pre-positioned with
discharge facing down; left or right discharge requires 90-degree transition
duct rotation. Transition duct can also be mounted to back of chassis
housing with minimum 3-3/4" clearance to back of cabinet wall.
Consider ductwork location before cutting hole in cabinet.
For maximum efficiency, use shortest and straightest duct run possible.
System operates most efficiently with up to 60 equivalent feet of duct;
Downdraft Vent operates properly with ductwork up to 100 equivalent
feet.
(Refer to Calculating Duct Length Table in Product Installation Guide.)
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
Thermal breaks such as short section of nonmetallic duct, should be used
in areas of extreme cold. Cold weather installations should have additional
backdraft damper installed.
High level of airflow may affect gas flame on some gas cooktop models.
Blower Motor System Options
1600 CFM Remote Blower Motor System Kit – (PN # EI16DDPRKS).
600 CFM Integrated Blower Motor System Kit – (PN # EI06DDPIKS).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.