Electrolux EIED55HIW Product Specifications Sheet (English) - Page 2

Front, Built-In Installations - installation instructions

Page 2 highlights

Electric Front Load Dryers EIED55H MB, EIED55H IW Front 27" 31 1/2"* Left 50 5/8"* Reversible Door Swing Rear 38" (53" with pedestal) 6 1/2" 19 1/8" 12 1/2" 240V Power supply 27" Front 26 7/16" Left 15" 15" Drawer Pedestal Installation Elevates dryer height to 53". For detailed pedestal installation, refer to instructions included with pedestal or on web. Note: Pedestal Installation requires modified utility hookup locations. For details, refer to Product Installation Guide on web. 4" 23 1/2" 3 7/16" Built-In Installations For built-in installations, NO minimum clearance required around sides or backs of units. For closet installation, allow 1" clearance between fronts of units and door. Location of plumbing, exhaust and utility hookups MUST be considered in built-in installations. For additional installation details, refer to Product Installation Guides on web. 13 1/2" 90° 90° 753/4" min. Dryer 90° Countertop 54" min. 90° 38" min. Washer Dryer 311/2"* Side-by-Side Units in Under-Counter Installation Requires custom-built countertop and/or cabinetry. * To achieve minimal depth dimensions or clearances, dryer MUST be vented straight back or with quick-turn 90° elbow. Washer 311/2" min.* 27" min. Stacked Units in Recessed or Closet Installation For detailed stacked installation, refer to instructions included with Stacking Kit or on web. Note: Stacked installation requires modified utility hookup locations for dryer. For details, refer to Product Installation Guide on web. Electric Dryer Specifications • Product Weight - 130 Lbs. • Voltage Rating - 240V / 60 Hz / 30 Amps • Single phase 3- or 4-wire cable, 240 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. (Do not use same circuit as washer.) • Connected Load (kW Rating) @ 240 Volts = 6.48 kW • Amps @ 240 Volts = 27 Amps • Dryer MUST employ a 3-conductor NEMA 10-30 type SRDT or 4-conductor NEMA 14-30 type SRDT or ST (as required), rated at 240 volt AC minimum, 30 amp power supply cord marked for use with clothes dryers (not supplied). • Grounding through neutral link prohibited in specific applications and certain locales, requiring use of 4-wire system. (For detailed electrical requirements, refer to Product Installation Guide on web.) • Always consult local and /or national electric codes. • Can be installed alone, with or without optional 15" drawer pedestal, or stacked above matching Electrolux Washer, which requires stacking kit included with dryer. (For installation details, refer to instructions included with optional pedestal or stacking kit or on web.) • Can be built in with matching Electrolux Washer in under-counter, recessed or closet installation. Installations requiring countertop and / or cabinetry will require custom building. (Refer to Built-In Installations on this page for cutout dimensions. For additional installation details, refer to Product Installation Guide on web.) • Closet installation requires vented door with 2 unobstructed louvered openings, minimum 60 sq. in. each, located 3" from top and bottom of door. Full-length 120 sq. in. opening also acceptable. Allow 1" clearance between door and fronts of units. • Do NOT install in area exposed to dripping water or outdoor weather conditions, or where gasoline or other flammables, including automobiles, are kept or stored. • Floor MUST be solid with 1" maximum slope. To ensure vibration or movement does not occur, reinforcement of floor may be necessary. Do NOT install on carpeted surface. • Dryer MUST exhaust to outside of building, NOT into any concealed space. • Exhaust installation requires minimum 4"-diameter rigid or flexible metal duct with approved vent hood having swing-out damper(s). Do NOT use flexible plastic or metal foil duct and use shortest run possible. • Leveling legs supplied to level dryer properly and reduce excessive noise and vibration. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions. Optional Accessories • Drawer Pedestals - Mediterranean Blue (EPWD15MB), Island White (EPWD15IW). • Mobile Home Installation Kit - (137067200). Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca EIED55H 08/08 © 2008 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2

Electric Front Load Dryers
EIED55H MB, EIED55H IW
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
EIED55H
08/08
© 2008 Electrolux Home Products, Inc.
Printed in the U.S.A.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electric Dryer Specifications
Product Weight – 130 Lbs.
Voltage Rating – 240V/60Hz/30 Amps
Single phase 3- or 4-wire cable, 240 Volt, 60 Hertz AC only electrical
supply with ground required on separate circuit fused on both sides
of line.
(Do not use same circuit as washer.)
Connected Load (kW Rating) @ 240 Volts = 6.48kW
Amps @ 240 Volts = 27 Amps
Dryer MUST employ a 3-conductor NEMA 10-30 type SRDT or
4-conductor NEMA 14-30 type SRDT or ST
(as required),
rated at
240 volt AC minimum, 30 amp power supply cord marked for use
with clothes dryers
(not supplied)
.
Grounding through neutral link prohibited in specific applications and
certain locales, requiring use of 4-wire system.
(For detailed electrical
requirements, refer to Product Installation Guide on web.)
Always consult local and/or national electric codes.
Can be installed alone, with or without optional 15" drawer pedestal,
or stacked above matching Electrolux Washer, which requires stacking
kit included with dryer.
(For installation details, refer to instructions
included with optional pedestal or stacking kit or on web.)
Can be built in with matching Electrolux Washer in under-counter,
recessed or closet installation. Installations requiring countertop and/
or cabinetry will require custom building.
(Refer to Built-In Installations
on this page for cutout dimensions. For additional installation details,
refer to Product Installation Guide on web.)
Closet installation requires vented door with 2 unobstructed louvered
openings, minimum 60 sq.in. each, located 3" from top and bottom of
door. Full-length120 sq.in. opening also acceptable. Allow 1" clearance
between door and fronts of units.
Do NOT install in area exposed to dripping water or outdoor weather
conditions, or where gasoline or other flammables, including automobiles,
are kept or stored.
Floor MUST be solid with 1" maximum slope. To ensure vibration or
movement does not occur, reinforcement of floor may be necessary.
Do NOT install on carpeted surface.
Dryer MUST exhaust to outside of building, NOT into any concealed space.
Exhaust installation requires minimum 4"-diameter rigid or flexible metal
duct with approved vent hood having swing-out damper(s). Do NOT use
flexible plastic or metal foil duct and use shortest run possible.
Leveling legs supplied to level dryer properly and reduce excessive
noise and vibration.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Drawer Pedestals – Mediterranean Blue (EPWD15MB),
Island White (EPWD15IW).
Mobile Home Installation Kit – (137067200).
15"Drawer
Pedestal Installation
Elevates dryer height to 53".
For detailed pedestal installation,
refer to instructions included
with pedestal or on web.
Note:
Pedestal Installation
requires modified utility hookup
locations. For details, refer to
Product Installation Guide
on web.
26
7
/
16
"
Left
15"
27"
Front
27"
Front
38"
(53"with
pedestal)
Rear
13
1
/
2
"
12
1
/
2
"
3
7
/
16
"
6
1
/
2
"
240V
Power
supply
Stacked Units in Recessed
or Closet Installation
For detailed stacked installation, refer
to instructions included with Stacking
Kit or on web.
Note:
Stacked installation
requires modified utility hookup locations
for dryer. For details, refer to Product
Installation Guide on web.
* To achieve minimal depth dimensions or clearances, dryer
MUST be vented straight back or with quick-turn 90
°
elbow.
Built-In Installations
For built-in installations, NO minimum clearance required
around sides or backs of units. For closet installation, allow
1" clearance between fronts of units and door. Location of
plumbing, exhaust and utility hookups MUST be considered in
built-in installations. For additional installation details, refer
to Product Installation Guides on web.
Side-by-Side Units in Under-Counter Installation
Requires custom-built countertop and/or cabinetry.
54"min.
90
°
38"
min.
90
°
Countertop
Dryer
Washer
31
1
/
2
"*
27" min.
90
°
75
3
/
4
"
min.
31
1
/
2
"min.*
Dryer
Washer
90
°
23
1
/
2
"
50
5
/
8
"*
31
1
/
2
"*
Left
Reversible
Door Swing
4"
19
1
/
8
"