Electrolux RH36PC60GS Product Specifications Sheet (English) - Page 2

Glass Canopy Island Ceiling-Mount Hood - range hood

Page 2 highlights

Glass Canopy Island Ceiling-Mount Hood RH36PC60G S 36" Glass Canopy Island Ceiling-Mount Hood Specifications • Product Weight - 84 Lbs. • Island / Peninsula Installation • Ventilation system is preset to exhaust air outside. If outside ducting is not possible, optional Duct-Free Kit (PN # RHDFP60GS) is available to convert ventilation to allow air to recirculate inside. (Refer to Ducted Option Specifications for outside ventilation.) • Sones Rating - 9.9 • Voltage Rating - 120V / 60 Hz / 15 Amps • Connected Load (kW Rating) @ 120 Volts = 0.516 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 4.16 Amps • Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale. • Minimum installation height allowed from bottom of hood to cooking surface is 24" - 30" for electric and 30" for gas. (NOT more than 36" recommended.) • To prepare mounting surface, adequate structure and support must be provided, capable of supporting 150 lbs. Ducted Option Specifications • For outside ventilation. • Exhaust Duct Required - 8" round • For most efficient airflow exhaust, use a straight run or as few elbows as possible. • Use metallic flex ducting only to connect rigid duct directly to transitions (if allowed by code). • Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. • Cold weather installations should have additional backdraft damper installed. • Refer to installation instructions on web for detailed exhaust duct preparation and converting vent blower system for recirculating inside. Pre-Installation Calculations • Select hood preference height (P) that is comfortable for user (24" - 30" minimum allowed, NOT more than 36" recommended). • Calculate hood height (H) for installation (H = K-C-P). • Confirm that (H) is within minimum to maximum range for hood. If not, adjust installation. • Calculate chimney structure height (S). Use formulas, check dimensions of hood. Save calculation for use later in installation. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.ca for detailed instructions. Optional Accessories • Duct-Free Kit (Single Pack) - (PN # RHDFP60GS). Electrolux Major Appliances, N.A. CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca RH36PC60GS 12/10 © 2010 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in Canada

  • 1
  • 2

Glass Canopy Island Ceiling-Mount Hood
RH36PC60G S
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
RH36PC60GS
12/10
© 2010 Electrolux Home Products, Inc.
Printed in Canada
36" Glass Canopy Island
Ceiling-Mount Hood Specifications
Product Weight – 84 Lbs.
Island / Peninsula Installation
Ventilation system is preset to exhaust air outside. If outside ducting is
not possible, optional Duct-Free Kit (PN # RHDFP60GS) is available to
convert ventilation to allow air to recirculate inside.
(Refer to Ducted
Option Specifications for outside ventilation.)
Sones Rating – 9.9
Voltage Rating –120V /60 Hz/15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.516 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 4.16 Amps
Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
Minimum installation height allowed from bottom of hood to cooking
surface is 24"- 30" for electric and 30" for gas.
(NOT more than 36"
recommended.)
To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 150 lbs.
Ducted Option Specifications
For outside ventilation.
Exhaust Duct Required – 8" round
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code)
.
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
installed.
Refer to installation instructions on web for detailed exhaust duct
preparation and converting vent blower system for recirculating inside.
Pre-Installation Calculations
Select hood preference height (P) that is comfortable for user
(24"- 30" minimum allowed, NOT more than 36" recommended).
Calculate hood height (H) for installation (H = K-C-P).
Confirm that (H) is within minimum to maximum range for hood.
If not, adjust installation.
Calculate chimney structure height (S). Use formulas, check
dimensions of hood. Save calculation for use later in installation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.ca for detailed instructions.
Optional Accessories