Epson ActionTower 7500 Product Information Guide - Page 3

Power Supply, Environmental Requirements, Jumper Settings

Page 3 highlights

EPSON ActionPC/ActionTower 7000 series (including ActionTower 8400) Power Supply Type Input ranges 200 Watt, UL/TUV/CSA listed, fan-cooled 100-120 VAC or 200-240 VAC; switch-selectable Maximum output +5 VDC at 20 Amps, -5 VDC at 0.5 Amp +12 VDC at 8 Amps, -12 VDC at 0.5 Amp Frequency 50 to 60Hz Cables Two to main system board, five to mass storage devices; for more than five devices, Y cables can be installed on the existing cables Option slot power limits output voltage (VDC) ) +5 volts For all slots 1 12 Amps l-5 volts 1 0.4 Amp 1 +12 volts I-12 volts 1 4.0 Amps ] 0.4 Amp Environmental Requirements Condition Temperature Humidity (non-condensing) Altitude 1 Operating range 41° to 90° F (5° to 32° C) 20% to 90% -330 to 9,900 ft (-100 to 3,000 m) 1 Storage range -4° to 140°F (-20° to 60° C) 10% to 90% -330 to 39,600 ft (-100 to 12,000 m) Jumper Settings Miscellaneous jumper settings Jumper number JP4 JP5 JP11 JP12 JP15 Jumper setting 1-2* 2-3 1 Off lOtI' 1-2 On off' 1-2 l 1 2-3 I 1-2* 1 2-3 Function Selects 5V flash memory Selects 12V flash memory 1 EPROM I Enables PCI IDE controller Disables PCI IDE controller Clears CMOS memory (resets SETUP values to factory defaults) Normal CMOS values Enables on-board I/O controller Disables on-board I/O controller ( Enables on-board VGA controller ) Disables on-board VGA controller * Default setting Parallel port ECP mode DRQ jumper settings Function DRQ1 (DACK1)* DRQ4 (DACK3) * Default setting JP13 1-2 2-3 JP14 1-2 2-3 * Off for DX4 (3x); 2-3 for DX2 (2X) 10/30/95 ActionPC/ActionTower 7000 series (including ActionTower 8400) - 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

EPSON ActionPC/ActionTower 7000 series (including ActionTower 8400)
Power Supply
Type
200 Watt, UL/TUV/CSA listed, fan-cooled
Input ranges
100-120 VAC or 200-240 VAC;
switch-selectable
Maximum
+5 VDC at 20 Amps, -5 VDC at 0.5 Amp
output
+12 VDC at 8 Amps, -12 VDC at 0.5 Amp
Frequency
50 to 60Hz
Cables
Two to main system board, five to mass
storage devices; for more
than
five
devices, Y cables can be installed on the
existing cables
Option slot power limits
output voltage (VDC)
)
+5 volts
l-5
volts
1
+12 volts
I-12
volts
For
all slots
1
12
Amps
1
0.4 Amp
1
4.0
Amps
]
0.4 Amp
Environmental Requirements
Condition
Temperature
1
Operating range
41° to 90° F
1
Storage range
-4° to 140°F
Humidity
(non-condensing)
Altitude
(5° to 32° C)
(-20° to 60° C)
20% to 90%
10% to 90%
-330 to 9,900 ft
-330 to 39,600 ft
(-100 to 3,000 m)
(-100 to 12,000 m)
Jumper Settings
*
Off for DX4 (3x); 2-3 for DX2 (2X)
Miscellaneous jumper settings
Jumper
number
JP4
JP5
Jumper
setting
1-2*
2-3
1
Off
lOtI’
Function
Selects 5V flash memory
Selects 12V flash memory
1
EPROM
I Enables PCI IDE controller
JP11
JP12
1-2
On
off’
1-2
l
Disables PCI IDE controller
Clears CMOS memory (resets SETUP values to
factory
defaults)
Normal CMOS values
Enables on-board I/O controller
JP15
1
2-3
I 1-2*
Disables on-board I/O controller
(
Enables on-board VGA controller
1
2-3
* Default setting
)
Disables on-board VGA controller
Parallel port ECP mode DRQ jumper settings
Function
JP13
JP14
DRQ1 (DACK1)*
1-2
1-2
DRQ4 (DACK3)
2-3
2-3
* Default setting
10/30/95
ActionPC/ActionTower 7000 series
(including ActionTower 8400) - 3