Epson EMP 600 Quick Reference Guide - Page 15

Checking the Indicators, Operation, indicator, Temperature - lamp

Page 15 highlights

Page 80 of User's Guide Checking the Indicators The projector is equipped with indicators that alert you to problems with projector operation. The following tables show what the indicators mean and how to remedy problems that they indicate. Lamp Temperature Operation indicator indicator indicator Indicator status lit flashing Problem and remedy Indicator status Problem and remedy Standby condition. Projection starts when the is pressed. button Cool-down in progress. After approximately 2 minutes, the projector switches to the standby condition (the indicator lights orange). Projecting in progress. Warm-up in progress. After warm-up is complete, projection will start when a video signal is input. Internal problem. Stop using the projector and ask for projector to be repaired. *1 This can happen when the power cord was disconnected from the electrical outlet before the cool-down period had finished the last time the projector was turned off. Wait about 2 minutes. After about 2 minutes, disconnect the power plug and remove the lamp. After checking if the lamp is broken, reinstall it and then and then reinsert the power plug. Check that the lamp is properly installed and the lamp cover is closed. Or, replace the lamp with a new one. *2 Lamp will soon need to be replaced. Replace the lamp as soon as possible. *2 The appearance of the operation indicator at this time will vary depending on the status of the projector. High temperature inside projector (overheating). The lamp will turn off automatically and projection will stop. Wait for about 5 minutes without operating the projector. After 5 minutes have elapsed, disconnect the power plug and then re-insert it. High-speed cooling in progress. If the internal temperature rises any higher, projection will stop. Check that the air inlet and exhaust vents are clear and that the indoor temperature is not too high. *1 If an indicator is showing a status which does not appear in the previous tables, contact your dealer or the nearest address provided at "International Warranty Conditions" in Safety Instructions/World-Wide Warranty Terms included in the package. *2 Contact your dealer for a spare lamp. Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Checking the Indicators
The projector is equipped with indicators that alert you to problems with projector operation.
The following tables show what the indicators mean and how to remedy problems that they indicate.
Indicator status
Problem and remedy
Standby condition.
Projection starts when the
button
is pressed.
Internal problem.
Stop using the projector and ask for
projector to be repaired.
*1
High-speed cooling in progress.
If the internal temperature rises any higher,
projection will stop.
Check that the air inlet and exhaust vents are clear
and that the indoor temperature is not too high.
Lamp will soon need to be replaced.
Replace the lamp as soon as possible.
*2
The appearance of the operation indicator
at this time will vary depending on the status
of the projector.
Indicator status
Problem and remedy
Check that the lamp is properly installed
and the lamp cover is closed.
Or, replace the lamp with a new one.
*2
lit
flashing
*1
If an indicator is
showing a status which does not appear in the
previous tables, contact your dealer or the nearest address provided at
“International Warranty Conditions” in Safety Instructions/World-Wide
Warranty Terms included in the package.
*2
Contact your dealer for a spare lamp.
Projecting in progress.
Cool-down in progress.
After approximately 2 minutes, the projector
switches to the standby condition
(the indicator lights orange).
Warm-up in progress.
After warm-up is complete, projection
will start when a video signal is input.
Page 80 of User's Guide
This can happen when the power cord was
disconnected from the electrical outlet
before the cool-down period had finished the
last time the projector was turned off.
Wait about 2 minutes. After about 2 minutes,
disconnect the power plug and remove the
lamp. After checking if the lamp is broken,
reinstall it and then and then reinsert the
power plug.
High temperature inside projector (overheating).
The lamp will turn off automatically and
projection will stop. Wait for about 5 minutes
without operating the projector. After 5 minutes
have elapsed, disconnect the power plug and
then re-insert it.
Troubleshooting
Operation
indicator
Lamp
indicator
Temperature
indicator