Epson ES-800C Product Information Guide - Page 3

ES-800C, Initialization, Problems and Solutions

Page 3 highlights

Resolution guidelines This table shows the recommended resolutions in dots per inch or pixels per inch for the image types and printing methods. Also, you may want to experiment with your scanner settings, possibly using a cropped version of your image to save time, until you achieve the desired results. Black and white printer Electroniccolor printer Printing presu'lmagesetter Line art 300-400 7 300-400 400-800 Gray scale 5 150-200 150-200 Color 75 150-200 150-200 Data format Initialization The scanner can be initialized (returned to a fixed set of conditions) in three ways. Hardware initialization: 0 When the power is turned on. Ll When the scanner receives an INIT signal at the parallel interface (pin 31 goes low). Software initialization: Ll When the software command ESC 62 (initialize the scanner) is received. Default settings The table below shows the default conditions when the scanner is initialized. Item Data format Resolution Size Reading area Color mode 1 Default 1 bit/pixel/color 1 100 dpi 1100% 1850 x 1170 dots, no offset 1 Monochrome (standard) When the scanner is initialized, the scanner terminates the scanning operation, and the carriage returns to the home position (rear of the scanner). ES-800C Problems and Solutions The problems you may have while using the scanner often involve the operation of your software and computer. Problems fall in the following major categories: Ll Incorrect setup of the interface CI Inappropriate selection of the scanner functions Ll Incorrect setup of your computer or software Cl Incorrect operation of your software. Scanner errors If an error occurs, the scanner stops operating and the READY and ERROR lights show the type of error. ~~ Command error The scanner received incorrect commands from your scanning software. When this error occurs, try the scanning operation with your software over again. The scanner returns to normal when it receives correct commands. Normally you do not need to reset the scanner. Interface error The interface setup is wrong, or the scanner is not properly connected to the computer. When this error occurs, check the interface connection. Push the RESET button or turn the scanner off and then back on to reset it. Fatal error This indicates one of the following problems: One or more fluorescent lamps needs to be replaced. The transportation screw is not released. The scanner is broken. There is a problem, such as an open cover, with the optional automatic document feeder. Check that the transportation screw is released and check the automatic document feeder; then push the RESET button. If the scanner still does not operate properly, try turning the scanner off and then back on. If the scanner still does not operate properly, or if this error occurs repeatedly, consult your dealer. Scanners 1112i92 ES-800C-3

  • 1
  • 2
  • 3
  • 4
  • 5

ES-800C
Resolution guidelines
This table shows the recommended resolutions in dots per
inch or pixels per inch for the image types and printing
methods. Also, you may want to experiment with your
scanner settings, possibly using a cropped version of your
image to save time, until you achieve the desired results.
Black and white printer
Electroniccolor printer
Printing
presu’lmagesetter
Line art
Gray scale
Color
300-400
7
5
75
300-400
150-200
150-200
400-800
150-200
150-200
Data format
Initialization
The scanner can be initialized (returned to a fixed set of
conditions) in three ways.
Hardware initialization:
0
When the power is turned on.
Ll
When the scanner receives an INIT signal at the parallel
interface (pin 31 goes low).
Software initialization:
Ll
When the software command ESC 62 (initialize the
scanner) is received.
Default settings
The table below shows the default conditions when the
scanner is initialized.
Item
Data format
1
Default
1 bit/pixel/color
Resolution
Size
1
100 dpi
1100%
Reading area
Color mode
1850
x
1170 dots, no offset
1
Monochrome (standard)
When the scanner is initialized, the scanner terminates the
scanning operation, and the carriage returns to the home
position (rear of the scanner).
Problems and Solutions
The problems you may have while using the scanner often
involve the operation of your software and computer.
Problems fall in the following major categories:
Ll
Incorrect setup of the interface
CI
Inappropriate selection of the scanner functions
Ll
Incorrect setup of your computer or software
Cl
Incorrect operation of your software.
Scanner errors
If an error occurs, the scanner stops operating and the
READY
and
ERROR
lights show the type of error.
~~
Command error
The scanner received incorrect commands from your
scanning software.
When this error occurs, try the scanning operation with your
software over again. The scanner returns to normal when it
receives correct commands. Normally you do not need to
reset the scanner.
Interface error
The interface setup is wrong, or the scanner is not properly
connected to the computer.
When this error occurs, check the interface connection. Push
the
RESET
button or turn the scanner off and then back on to
reset it.
Fatal error
This indicates one of the following problems:
One or more fluorescent lamps needs to be replaced.
The transportation screw is not released.
The scanner is broken.
There is a problem, such as an open cover, with the
optional automatic document feeder.
Check that the transportation screw is released and check the
automatic document feeder; then push the
RESET
button. If
the scanner still does not operate properly, try turning the
scanner off and then back on. If the scanner still does not
operate properly, or if this error occurs repeatedly, consult
your dealer.
Scanners
1112i92
ES-800C-3