Epson Endeavor 486I Product Information Guide - Page 3
Jumper Settings
View all Epson Endeavor 486I manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
EPSON ActionPC 7000, ActionTower 7000, Endeavor 486i Power Supply Type Input ranges 200 Watt, UL/TUV/CSA listed, fan-cooled 100-120 VAC or 200-240 VAC; switch-selectable Maximum output +5 VDC at 20 Amps, -5 VDC at 0.5 Amp +12 VDC at 8 Amps, -12 VDC at 0.5 Amp Frequency 50 to 60 Hz Cables Two to main system board, five to mass storage devices; for more than five devices, Y cables can be installed on the existing cables Option slot power limits Output voltage (VDC) 1+5 Volts 1-5 Volts Environmental Requirements Condition Temperature 1Operating range 141°t0900F + Humidity (non-condensing) Altitude -330 to 9,900 ft 1Storage range I-4' to 140° F -330 to 39,600 ft CPU type jumper settings Jumper Settings Miscellaneous jumper settings I Function Enables on-board l/O controller 4 Disables on-board l/O controller Selects 5V flash ROM Selects 12V flash ROM I EPROM Enables PCI IDE controller Disables PCI IDE controller Clears CMOS memory (resets SETUP values to factory defaults) I Normal CMOS values ,,,, Enables on-board VGA controller I Disables on-board VGA controller * Default setting Parallel port ECP mode DRQ jumper settings Function JP8 DRQ1 (DACK1)* 1-2 DRQ4 (DACK3) 2-3 * Default setting JP18 2-3 1-2 5/19/95 ActionPC 7000, ActionTower 7000, Endeavor 486i - 3