■ Use only the type of power source indicated on the AC adapter's label, and always supply power directly from a standard domestic electrical outlet with the AC power cord that meets the relevant local safety standards. ■ Avoid using outlets on the same circuit as photocopiers or air control systems that regularly switch on and off. ■ If you use an extension cord with the scanner, make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord's ampere rating. Also, make sure the total ampere rating of all devices plugged into the electrical outlet does not exceed the electrical outlet's ampere rating. Do not place multiple loads on the electrical outlet. ■ Never disassemble, modify, or attempt to repair the AC adapter, power cord, scanner, and transparency unit by yourself. ■ Do not insert objects into any opening as they may touch dangerous voltage points or short out parts. Beware of electrical shock hazards. ■ Unplug the scanner and the AC adapter, and refer servicing to qualified service personnel under the following conditions: The power cord or plug is damaged; liquid has entered the scanner or the AC adapter; the scanner or the AC adapter has been dropped or the case damaged; the scanner or AC adapter does not operate normally or exhibits a distinct change in performance. (Do not adjust controls that are not covered by operating instructions.) ■ Unplug the scanner and the AC adapter before cleaning. Clean with a damp cloth only. Do not use liquid or aerosol cleaners. ■ If you are not going to use the scanner for a long period, be sure to unplug the AC adapter from the electrical outlet. ■ This product includes a lamp component that contains mercury (Hg). Please consult your state/provincial and local regulations regarding proper disposal or recycling. Do not put it in the trash. Specifications Note: For a complete list of specifications, see your on-screen Reference Guide. General Scanner type Photoelectric device Effective pixels Maximum document size Scanning resolution Output resolution Scanning speed Flatbed, color Color CCD line sensor 10200 × 14040 pixels at 1200 dpi 216 × 297 mm (8.5 × 11.7 inches) US letter or A4 size; reading area can be specified from your software 1200 dpi (main scan) 2400 dpi with Micro Step Drive™ (subscan) 50 to 9600 dpi (50 to 4800 dpi in 1 dpi increments; 7200 and 9600 dpi performed with zoom function) 8 msec/line at 1200 dpi 8 msec/line at 2400 dpi 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

10
Use only the type of power source indicated on the AC adapter’s label, and always supply
power directly from a standard domestic electrical outlet with the AC power cord that meets
the relevant local safety standards.
Avoid using outlets on the same circuit as photocopiers or air control systems that regularly
switch on and off.
If you use an extension cord with the scanner, make sure the total ampere rating of the devices
plugged into the extension cord does not exceed the cord’s ampere rating. Also, make sure the
total ampere rating of all devices plugged into the electrical outlet does not exceed the electrical
outlet’s ampere rating. Do not place multiple loads on the electrical outlet.
Never disassemble, modify, or attempt to repair the AC adapter, power cord, scanner, and
transparency unit by yourself.
Do not insert objects into any opening as they may touch dangerous voltage points or short
out parts. Beware of electrical shock hazards.
Unplug the scanner and the AC adapter, and refer servicing to qualified service personnel
under the following conditions: The power cord or plug is damaged; liquid has entered the
scanner or the AC adapter; the scanner or the AC adapter has been dropped or the case
damaged; the scanner or AC adapter does not operate normally or exhibits a distinct change in
performance. (Do not adjust controls that are not covered by operating instructions.)
Unplug the scanner and the AC adapter before cleaning. Clean with a damp cloth only. Do
not use liquid or aerosol cleaners.
If you are not going to use the scanner for a long period, be sure to unplug the AC adapter
from the electrical outlet.
This product includes a lamp component that contains mercury (Hg). Please consult your
state/provincial and local regulations regarding proper disposal or recycling. Do not put it in
the trash.
Specifications
Note:
For a complete list of specifications, see your on-screen
Reference Guide
.
General
Scanner type
Flatbed, color
Photoelectric device
Color CCD line sensor
Effective pixels
10200 × 14040 pixels at 1200 dpi
Maximum document
size
216 × 297 mm (8.5 × 11.7 inches)
US letter or A4 size; reading area can be specified from your software
Scanning resolution
1200 dpi (main scan)
2400 dpi with Micro Step Drive
(subscan)
Output resolution
50 to 9600 dpi (50 to 4800 dpi in 1 dpi increments; 7200 and 9600 dpi
performed with zoom function)
Scanning speed
8 msec/line at 1200 dpi
8 msec/line at 2400 dpi