Epson Perfection 640U Product Information Guide - Page 2

Environmental, Safety Approvals, USB Interface, EN 55022 CISPR Pub 22 class B - scanner

Page 2 highlights

EPSON Perfection 640U Environmental Temperature Humidity (without condensation) Operating conditions Operation: 41 to 95 °F (5 to 35 °C) Storage: -13 to 140 °F (-25 to 60 °C) Operation: 10% to 80% Storage: 10% to 85% Ordinary office or home conditions; avoid extreme dust, direct sunlight, and strong light sources. Make sure the outlet provides enough power. Safety Approvals 120 V model Safety standards UL 1950 CSA C22.2 No. 950 EMC FCC part 15 subpart B class B CSA C108.8 class B 230 V model Safety standards EN 60950 EMC EN 55022 (CISPR Pub 22) class B AS/NZS 3548 class B CE marking 230 V model Low Voltage Directive 73/23/EEC EN 60950 EMC Directive 89/336/EEC EN 55022 Class B EN 50082-1 IEC 60801-2 IEC 60801-3 IEC 60801-4 USB Interface Interface type Configuration Universal Serial Bus Specification Revision 1.1 Element Configuration Interface Endpoint 1 Endpoint 2 String Descriptor Description Characteristics: Self-powered Remote wake up feature: Not supported Maximum power consumption from VBUS: 2mA (5V) No alternate setting Number of endpoints used by this interface (excluding endpoint 0): 2 Class: Vendor specific Bulk IN transfer Maximum data transfer size: 64 byte Bulk OUT transfer Maximum data transfer size: 64 byte Language ID: US English 1: Manufacturer: "EPSON" 2: Product: "Perfection 640U" Electrical standard Full Speed mode (12Mbit/s) of Universal Serial Bus Specification Revision 1.1 Connector type One receptacle (Type B) Connector pin arrangement Pin number 1 2 3 4 Signal VCC -DATA +DATA GND Connector Initialization methods The scanner can be initialized (returned to a fixed set of conditions) in the following ways: Hardware initialization Software initialization * The scanner is plugged in. * The USB cable is unplugged from the USB port on the scanner. * Software sends the ESC @ (initialize the scanner) command. * The scanner receives a Bus Reset from the USB interface. 2 - EPSON Perfection 640U 10/00

  • 1
  • 2
  • 3
  • 4
  • 5

EPSON Perfection 640U
2 -
EPSON Perfection 640U
10/00
Environmental
Temperature
Operation: 41 to 95 °F (5 to 35 °C)
Storage: –13 to 140 °F (–25 to 60 °C)
Humidity
Operation: 10% to 80%
(without
Storage: 10% to 85%
condensation)
Operating
Ordinary office or home conditions; avoid
conditions
extreme dust, direct sunlight, and strong
light sources. Make sure the outlet
provides enough power.
Safety Approvals
120 V model
Safety standards
UL 1950
CSA C22.2 No. 950
EMC
FCC part 15 subpart B class B
CSA C108.8 class B
230 V model
Safety standards
EN 60950
EMC
EN 55022 (CISPR Pub 22) class B
AS/NZS 3548 class B
CE marking
230 V model
Low Voltage Directive 73/23/EEC
EN 60950
EMC Directive 89/336/EEC
EN 55022 Class B
EN 50082-1
IEC 60801-2
IEC 60801-3
IEC 60801-4
USB Interface
Interface type
Universal Serial Bus Specification
Revision 1.1
Configuration
Electrical standard
Full Speed mode (12Mbit/s) of
Universal Serial Bus Specification
Revision 1.1
Connector type
One receptacle (Type B)
Connector pin arrangement
Initialization
The scanner can be initialized (returned to
methods
a fixed set of conditions) in the following
ways:
Element
Description
Configuration
Characteristics: Self-powered
Remote wake up feature: Not supported
Maximum power consumption from VBUS:
2mA (5V)
Interface
No alternate setting
Number of endpoints used by this interface
(excluding endpoint 0): 2
Class: Vendor specific
Endpoint 1
Bulk IN transfer
Maximum data transfer size: 64 byte
Endpoint 2
Bulk OUT transfer
Maximum data transfer size: 64 byte
String Descriptor
Language ID: US English
1: Manufacturer: “EPSON”
2: Product: “Perfection 640U”
Pin number
Signal
Connector
1
VCC
2
DATA
3
+DATA
4
GND
Hardware
initialization
*
The scanner is plugged in.
*
The USB cable is unplugged from the USB port
on the scanner.
Software
initialization
*
Software sends the ESC @ (initialize the scanner)
command.
*
The scanner receives a Bus Reset from the USB
interface.