Epson TM-T20II-i ePOS-Device XML Users Manual For TM-i firmware v4.1 - Page 45
Programming Guide, Acquires the transfer history of the Communication Box
View all Epson TM-T20II-i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Application A ePOS-Device Acquires the transfer history of the Communication Box Closes the Communication Box 3 box1 "\0" 2 getcommhistory box1 OK member1 send_message 3 "\0" 3 box1 OK 3 "\0" 3 box1 OK 4 "\0" Chapter 3 Programming Guide Application B 2 getcommhistory box1 "\0" 3 3 box1 "\0" 45
45
Chapter 3
Programming Guide
3
Acquires the transfer history of the Communication Box
<commbox_data>
<sequence>2</sequence>
<data>
<type>
getcommhistory
</type>
<box_id>box1</box_id>
</data>
</commbox_data>"\0"
<commbox_data>
<sequence>2</sequence>
<data>
<type>
getcommhistory
</type>
<box_id>box1</box_id>
<code>OK</code>
<history_list>
<senderId>
member1
</senderId>
<receiverId>
</receiverId>
<message>
send_message
</message>
</history_list>
</data>
<data_id>3</data_id>
</commbox_data>"\0"
Closes the Communication Box
<close_commbox>
<sequence>3</sequence>
<data>
<box_id>box1</box_id>
</data>
</close_commbox>"\0"
<close_commbox>
<sequence>3</sequence>
<data>
<box_id>box1</box_id>
<code>OK</code>
</data>
<data_id>3</data_id>
</close_commbox>"\0"
<close_commbox>
<sequence>3</sequence>
<data>
<box_id>box1</box_id>
</data>
</close_commbox>"\0"
<close_commbox>
<sequence>3</sequence>
<data>
<box_id>box1</box_id>
<code>OK</code>
</data>
<data_id>4</data_id>
</close_commbox>"\0"
Application A
ePOS-Device
Application B